Chart 3: Paraplegic patients' EMG feedback functional electrical stimulation (Paraly-
sis of the legs) .

Chart4: EMG feedback functional electrical stimulation for 2 kinds of forearm move-
ments.

 

 

 

 

RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND

MOBILE RF COMMUNICATIONS EQUIPMENT

AND THE PORTABLE ELECTRICAL STIMULATOR UNIT

This Aspire 2 is intended for use in an electromagnetic environment in which radiated RF disturbances 
are controlled. The customer or the user of this Aspire 2 can help prevent electromagnetic interference 
by maintaining a minimum distance between portable and mobile RF communications equipment 
(transmitters) and this Aspire 2 as recommended below, according to the maximum output power of 
the communications equipment. 

 

Rated maximum output  

Separation distance according to frequency of transmitter

 

 

power of transmitter   

 

m

 

                            W 

150 KHz to 80 MHz 

80 MHz to 800 MHz  

800 MHz to 2.7 GHz

 

0.01  

0.12  

0.12

0.23

 

0.1  

0.38  

0.38 

0.73

1.2 

1.2

2.3

 

10  

3.8  

3.8

7.3

 

100  

12  

12

23

For transmitters rated at a maximum output power not listed above, the recommended separation distance ’d’ 
in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where ’P’ is 
the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

NOTE 1 - At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2 - These guidelines may not apply in all situations. Electromagnetic propagation is afected by 
                absorption and refection from structures, objects and people. 

d

 = 

1.2

d

 = 

d

 = 

Returning

 

Equipment

 

for

 

Repair

Be sure to call for an authorization number (RA) before returning any equipment.
Send  the  unit(s)  postage  prepaid  and  insured,  with  proof  of  purchase,  to  the 
address  below.  If  you  are  shipping  from  outside  the  United  States,  mark  the 
package ‘Goods to be repaired-Made in China’ to avoid unnecessary customs 
charges.

Provide a detailed description of the problem you are experiencing, along with your email,
phone number and fax number if applicable. 

Technical

 

Support

 

and

 

Repair

1.2

2.3

Any queries should be addressed to Spectramed at:275 W Johnstown Rd
Gahanna, OH 43230

Содержание 01AS80

Страница 1: ...m Date 2016 12 23 sEMG Biofeedback FES Neuro Muscular Electrical Stimulator 01AS80 User manual Thanks for buying our product Please carefully read the user manual before use and keep the manual in a safe place ...

Страница 2: ...ions Skin Care Chapter 3 The Aspire 2 Description Features Settings Chapter 4 Operation Power on Mode Selection Other Functions Chapter 5 Care and Maintenance Stimulator Battery Lead Wires Guardian Self Adhesive Electrodes Chapter 6 Specifications and Parameters Chapter 7 Manufacturer s Declaration Warranty Customer Service 01 01 01 02 04 04 04 04 05 06 06 07 07 07 08 09 09 09 13 15 15 15 16 16 17...

Страница 3: ...rehabilitation treatment programs for each patient 1 2 Main Innovations 1 Technology of self EMG signal acquisition and processing 2 New generation of real time biofeedback functional electrical stimulation technology based on EMG signal and muscle strength 3 iPad interactive games training and rehabilitation therapy applications APP 4 Multiple rehabilitation training modes in the APP Warranty Spe...

Страница 4: ...It is customer responsibility to assure that this equipment and vicinity equipment complies the value of radio frequency inter ferences shown in General Regulation for safety according to IEC 60601 1 2 Tables as described in this section The manufacturer is not responsible for any interference caused by using other than recommended interconnect cables or by unauthorized changes or modifcations to ...

Страница 5: ... 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequenc...

Страница 6: ...ld strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol MANUFACTURER S DECLARATION ELECTROMAGNETIC IMMUNITY This Aspire 2 is intended for use in the electromagnetic environment specified below The customer or the u...

Страница 7: ... 2 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment The Aspire 2 is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings and homes used for domestic purposes MANUFACTU...

Страница 8: ...atio 100dB NMES Frequency 5 100Hz biphasic balanced wave 10 Pulse width 50 450uS 10 Output intensity load 1000Ω min 1mA max 60mA ETS Frequency 18 Hz biphasic balanced wave 10 Pulse width 150 uS 10 Output intensity load 1000Ω min 1mA max 60mA Working Environment Temperature 5 40 Relative humidity 80 HR Atmos 86Kpa 106Kpa Storage Environment Temperature 20 55 Relative humidity 93 HR Atmos 70Kpa 106K...

Страница 9: ...wires carefully after each use Guardian Self Adhesive Electrodes Check the short connectors to make sure they have not become separated from the electrodes Replace electrodes onto plastic film after use If they drop onto the floor debris will adhere to conductive gel rendering the electrodes ineffective Optimal electrode function cannot be guaranteed after 4 uses Keep electrodes away from water Tr...

Страница 10: ...o not use cleaning sprays or alcohol based cleaning solutions Do not store in direct sunlight in high temperatures moist areas dusty areas or near corrosive gas Do not immerse in water Do not throw step on or exert pressure on the stimulator When the stimulator reaches the end of its service life 3 years please dispose of it in accordance with the local and national regulations Battery The Aspire2...

Страница 11: ... up the stimulator will shut down and cannot work again until downloading another treatment time from the APP 4 3 5 Current Limit A current limit value can be downloaded from the APP to limit the maximum output current The available working current of the stimulator is 0 to 60 mA however if the user downloads a current limit value of 25 mA from the APP then the maximum output current will stop at ...

Страница 12: ...e effort exerted and gives them a tangible goal to work towards thereby improving their performance and affecting a physiological change The animations provide an enjoyable engaging format during the rehabilitation process Different games have been designed specifically to address 3 different types of muscle function strength endurance and coordina tion The system transfers the collected EMG signa...

Страница 13: ...r muscle movements as the reliability of the signal will be directly impacted by the type of swallow elicited such as dry swallow 5cc water 10cc water puree or solid bolus Proper use of sEMG can be very useful in providing objective data for establishing baseline and progress over time Improper use of sEMG will not yield useful or accurate data The stimulator has 5 prescriptions as follows 4 fixed...

Отзывы: