SpectraLink Corporation
Installation and Administration
NetLink OAI Gateway
1.
Connect a terminal or PC to the Gateway’s serial port using a cable that
conforms to RS-232 standards for DTE to DTE connections (known as a null
modem cable).
OAI
Gateway
RS-232
port
LAN
Ethernet
switch
(terminal)
RS-232
port
2.
Reset the system. The following OAI command will display on the terminal:
04830130
.
3.
Type the following command on the terminal or PC keyboard:
0255CC [CTRL-M] [CTRL-J].
Note that this command will not display on the screen as it is typed.
4.
The
Login
prompt should display. If you made an error entering the command
string, the message for “Ill Formed Packet” will display (a series of numbers
followed by some version of the command you typed.) Repeat Steps 2 and 3
until you see the
Login
prompt.
5.
At the
Login
prompt, enter the default login: admin and default password: admin.
These are case sensitive.
6.
You can now configure the NetLink OAI Gateway (including IP address)
following the procedure explained in the next section.
Changing the IP Address
When utilizing the serial port as the primary communication link with the application
server, the OAI command described in step two above must be entered to free the
port and allow it to be used for administrative purposes.
The procedure for entering/changing the IP address of the NetLink OAI Gateway is
described below in section 4.2
IP Systems Main Menu
.
When the NetLink OAI Gateway has been configured, disconnect the terminal or
PC from the serial port, reconnect the communication cable between the NetLink
OAI Gateway and the application server, and reset the system. Normal
communication between the application server and OAI Gateway will resume.
PN: 72-0078-07-B.doc
Page 12