Spectra nTier Verde Array Скачать руководство пользователя страница 2

October 2013

Boot Drive Replacement

Spectra nTier Verde Array

2

Copyright

Copyright

 

©

 

2013

 

Spectra

 

Logic

 

Corporation.

 

All

 

rights

 

reserved.

 

This

 

item

 

and

 

the

 

information

 

contained

 

herein

 

are

 

the

 

property

 

of

 

Spectra

 

Logic

 

Corporation.

 

Notices

Except

 

as

 

expressly

 

stated

 

herein,

 

Spectra

 

Logic

 

Corporation

 

makes

 

its

 

products

 

and

 

associated

 

documentation

 

on

 

an

 

“AS

 

IS”

 

BASIS,

 

WITHOUT

 

WARRANTY

 

OF

 

ANY

 

KIND,

 

EITHER

 

EXPRESSED

 

OR

 

IMPLIED,

 

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO

 

THE

 

IMPLIED

 

WARRANTIES

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE,

 

BOTH

 

OF

 

WHICH

 

ARE

 

EXPRESSLY

 

DISCLAIMED.

 

In

 

no

 

event

 

shall

 

Spectra

 

Logic

 

be

 

liable

 

for

 

any

 

loss

 

of

 

profits,

 

loss

 

of

 

business,

 

loss

 

of

 

use

 

or

 

data,

 

interruption

 

of

 

business,

 

or

 

for

 

indirect,

 

special,

 

incidental

 

or

 

consequential

 

damages

 

of

 

any

 

kind,

 

even

 

if

 

Spectra

 

Logic

 

has

 

been

 

advised

 

of

 

the

 

possibility

 

of

 

such

 

damages

 

arising

 

from

 

any

 

defect

 

or

 

error.

Information

 

furnished

 

in

 

this

 

manual

 

is

 

believed

 

to

 

be

 

accurate

 

and

 

reliable.

 

However,

 

no

 

responsibility

 

is

 

assumed

 

by

 

Spectra

 

Logic

 

for

 

its

 

use.

 

Due

 

to

 

continuing

 

research

 

and

 

development,

 

Spectra

 

Logic

 

may

 

revise

 

this

 

publication

 

from

 

time

 

to

 

time

 

without

 

notice,

 

and

 

reserves

 

the

 

right

 

to

 

change

 

any

 

product

 

specification

 

at

 

any

 

time

 

without

 

notice.

Trademarks

BlueScale,

 

Spectra,

 

SpectraGuard,

 

Spectra

 

Logic,

 

TeraPack,

 

T

Finity,

 

and

 

TranScale

 

are

 

registered

 

trademarks

 

of

 

Spectra

 

Logic

 

Corporation.

 

ArchiveGrade

 

and

 

nTier

 

Verde

 

are

 

trademarks

 

of

 

Spectra

 

Logic

 

Corporation.

 

All

 

rights

 

reserved

 

worldwide.

 

All

 

other

 

trademarks

 

and

 

registered

 

trademarks

 

are

 

the

 

property

 

of

 

their

 

respective

 

owners.

Part Number

90990089

 

Revision

 

D

Revision

History

Revision

Date

Description

A

May

 

2013

Initial

 

release

B

June

 

2013

Updated

 

for

 

StrataView

 

1.1

 

release

C

August

 

2013

Updated

 

for

 

StrataView

 

1.2

 

release

D

October

 

2013

Updated

 

for

 

StrataView

 

1.3

 

release

Содержание nTier Verde Array

Страница 1: ...SpectraLogic com Spectra nTier Verde Array Boot Drive Replacement...

Страница 2: ...d of the possibility of such damages arising from any defect or error Information furnished in this manual is believed to be accurate and reliable However no responsibility is assumed by Spectra Logic...

Страница 3: ...support spectralogic com United States and Canada Phone Toll free US and Canada 1 800 227 4637 International 1 303 449 0160 Email support spectralogic com Europe Middle East Africa Phone 44 0 870 112...

Страница 4: ...ovide storage for the operating system and StrataView web interface The procedure is different for each size of master node Use the instructions in one of the following sections Replace a Boot Drive i...

Страница 5: ...rde 4U master node Estimated Time 30 minutes Before you Begin Before replacing a boot drive make sure that you have addressed the requirements in this section Gather Materials and Tools Required A gro...

Страница 6: ...i static bags Connect the wristband to the static protection mat or to other suitable ESD grounding Note Keep all electronic components in anti static bags when not in use Discontinue Storage Operatio...

Страница 7: ...the Power screen click Shutdown 3 A confirmation screen displays Confirm the selection to shutdown the nTier Verde array 4 Once the array finishes powering off disconnect the power cords from the pow...

Страница 8: ...the array Remove the Array From a Rack Use these instructions to remove the array from a rack 1 Using a 2 Phillips screwdriver remove the screw on each side of the front of the array Warning The Spect...

Страница 9: ...lly extended and the self locking latches engage on each rack rail 3 While supporting the front of the chassis with one hand press and hold the self locking latches on both inner rails downward While...

Страница 10: ...Any damage to the Spectra nTier Verde caused by failure to protect it from electrostatic discharge ESD voids the Spectra nTier Verde warranty To protect the Spectra nTier Verde drives from damage Wear...

Страница 11: ...closest to the chassis wall Note To remove boot drive 2 you must first remove boot drive 1 4 Locate the clip securing the boot drive to the motherboard Figure 10 shows the clip holding the drive You w...

Страница 12: ...from the failed module 9 Set the failed module aside for return to Spectra Logic see Returns on page 22 10 Connect the power cable to the replacement module The connector is keyed to only fit one way...

Страница 13: ...to reinstall the array in a rack 1 Pull the center section of the outer rails out of the rack until they are fully extended see Figure 13 on page 14 Figure 12 Orient the cover with the tabs facing to...

Страница 14: ...ack 3 Slide the chassis into the rack until the self locking latches engage 4 While supporting the front of the chassis with one hand press the self locking latches on both inner rails downward Push t...

Страница 15: ...es that you disconnected before removing the array from the rack 7 Power on the nTier Verde array by pressing the power button on the front panel The power LED illuminates indicating that power is on...

Страница 16: ...ive in the nTier Verde 2U master node Estimated Time 15 minutes Before You Begin Before replacing a boot drive make sure that you have addressed the requirements in this section Gather Materials and T...

Страница 17: ...c protection mat or to other suitable ESD grounding Note Keep all electronic components in anti static bags when not in use Discontinue Storage Operations Although the boot drives in the nTier Verde 2...

Страница 18: ...ed 2 Locate the boot drive you want to replace Drive 1 is on the left and drive 2 is on the right Caution Any damage to the Spectra nTier Verde caused by failure to protect it from electrostatic disch...

Страница 19: ...ately 20 seconds to allow the drive platters to stop spinning Then slide the drive completely out of the array This delay avoids causing additional damage that might interfere with failure analysis 5...

Страница 20: ...following instructions to reboot the array a From any screen of the StrataView interface click the Power icon in the lower right hand corner The Power screen displays b Click Reboot A confirmation scr...

Страница 21: ...us a check mark in a green circle If a boot drive does not indicate a good status contact Spectra Logic Technical Support see Contacting Spectra Logic on page 3 nTier Verde 2U master node Confirm the...

Страница 22: ...LL of the packaging material shipped with the replacement component including any anti static bags or foam inserts Use the return label and instructions that were included with the replacement compone...

Отзывы: