11.11 INSTALLER QUICK FUNCTIONS KEYS
After entering the Installer Code, you can press a key to perform specific actions as described below.
11.11.1 I
NSTALLER
T
EST
M
ODE
[
ENTER
] + [
INSTALLER
CODE
] + [
TBL
]
OR
[
TRBL
]
The Installer Test Mode allows you to perform walk tests where the bell or siren will squawk and the keypad will emit a
Confirmation Beep to indicate opened zones. To enter this mode, simply enter the Installer Code then press the
[
TBL
]
or
[
TRBL
]
key. The keypad will emit a confirmation beep. To disable this mode, press the
[
TBL
]
key again. The keypad
will emit a Rejection Beep.
11.11.2 T
EST
R
EPORT
[
ENTER
] + [
INSTALLER
CODE
] + [
MEM
]
Sends the Test Report report code programmed in section [211] to the central station (see
11.11.3 C
ALL
W
IN
L
OAD
S
OFTWARE
[
ENTER
] + [
INSTALLER
CODE
] + [
BYP
]
Refer to page 41.
11.11.4 C
ANCEL
C
OMMUNICATION
[
ENTER
] + [
INSTALLER
CODE
] + [
STAY
]
Cancels all communication until the next reportable event.
11.11.5 A
NSWER
W
IN
L
OAD
S
OFTWARE
[
ENTER
] + [
INSTALLER
CODE
] + [
FORCE
]
Refer to page 42.
11.12 PGM MODULES SUPERVISION
Section [129]: General Options
Option [7] OFF = 4-PGM Output Module Supervision Disabled (default)
Option [7] ON = 4-PGM Output Module Supervision Enabled
By enabling this option, the control panel will supervise the 4-PGM Output Module (APR3-PGM4) connected to the Spectra bus.
This means that whenever the module is disconnected or is not communicating with the control panel, the control panel will
attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the
keypads’ Trouble Display (see page 42).
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the APR3-
prefix are compatible with Spectra( versions 2.0 and higher), Digiplex and DigiplexNE.
11.13 PRINTER MODULE SUPERVISION
Section [129]: General Options
Option [8] OFF = Printer Module Supervision Disabled (default)
Option [8] ON = Printer Module Supervision Enabled
By enabling this option, the control panel will supervise the Printer Module (APR3-PRT1) connected to the Spectra bus. This
means that whenever the Printer Module is disconnected or is not communicating with the control panel, the control panel will
attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the
keypads’ Trouble Display (see page 42).
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the APR3-
prefix are compatible with Spectra( versions 2.0 and higher), Digiplex and DigiplexNE.
11.14 ZONE EXPANSION BUS MODULE SUPERVISION
Section [129]: General Options
Option [4] OFF = Zone Expansion Bus Module Supervision Disabled (default)
Option [4] ON = Zone Expansion Bus Module Supervision Enabled
By enabling this option, the control panel will supervise the 4- or 8-Zone Expansion Bus Module (SPC/APR3-ZX4 or SPC/APR3-
ZX8) connected to the Spectra bus. This means that whenever the Zone Expansion Bus Module is disconnected or is not
communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in
section [210] and the Module Loss Failure will appear in the keypads’ Trouble Display (see page 42).
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the APR3-
prefix are compatible with Spectra( versions 2.0 and higher), Digiplex and DigiplexNE.