PART 1: INTRODUCTION

1.1

FEATURES

• Up to 15 fully programmable zones
• Two completely independent partitions. Many of the features and options in the Spectra System can be independently set for 

each partition such as event reporting, entry/exit delay, auto-arming and many more. All zones, the keyswitches and all user 
codes are assigned to specific partitions, which makes this a true partitioned system.

• Communication bus facilitates the adding, programming and monitoring of all expansion modules. 
• 1 Installer Code and 48 User Codes (including: 1 System Master, 2 Masters, and 1 Duress)
• 2 on-board, fully programmable outputs (PGMs) and one 5A alarm relay
• Simple, direct and logical programming
• Event Call Direction: The Spectra 1759EX control panel events are divided into 5 groups of events. Each of these event groups 

can be programmed with a separate dialing sequence.

• Two 32-digit Central Station Telephone Numbers and one 32-digit Backup Telephone Number 
• Contact ID, Pager Format and many more High-Speed Communication Formats
• "False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay Before 

Alarm Transmission, and Recent Closing Report

• Regular Arming, Stay Arming, Instant Arming, Force Arming, One-Touch Arming, Auto-Arming, or Keyswitch Arming  
• 256 Event Buffer with time stamp
• Telephone Line Supervision
• Keypad activated panic alarms
• Compatible with Winload Security System Management Software for Windows®

1.2

SPECIFICATIONS

1.2.1

S

PECTRA

 1759EX C

ONTROL

 P

ANEL

AC Power:

16Vac transformer (refer to Table 1 on page 3) with minimum 20VA rating (Rec.: 
40VA), 50 to 60Hz 

Battery:

12Vdc, 4Ah/7Ah 

Aux.  Power:

+

600mA typical, 700mA maximum, fuseless shutdown @ 1.1A

Bell Output:

++

1A, fuseless shutdown @ 3A

PGM Outputs:

PGM1 = 150mA low-current output, PGM2 = 1A high-current output

Alarm Relay:

One form “C” relay rated @ 125V, 5A receptive load

Approvals:

433MHz 

868MHz  

Compliant to all EU and EFTA countries except Greece according

to RTT&E directives.

1.2.2

S

PECTRA

 K

EYPADS

 (1686H, 1686V, 1689 

AND

 1641)

Power input:

Typically 9-16Vdc

1 standard keypad zone

On-board tamper switch (optional)

1686H and 1686V 10-Zone LED Keypad

Current consumption:

62 to 116mA

1689 16-Zone LED Keypad

Current consumption:

50 to 117mA

1641 32-Character LCD Keypad

Current consumption:

60 to 80mA

PGM:

1 with 50mA current limit

LCD: 

Super Twisted Nematic display (STN), Wide viewing angle, Backlight & Contrast 
adjustable

Specifications may change without prior notice

+

 Cannot exceed 200mA for UL installations

++

 Cannot exceed 1A for UL installations

Содержание 1759ex

Страница 1: ...1759EX V1 0 REFERENCE INSTALLATION MANUAL 433MHZ 868MHZ 1759EX...

Страница 2: ......

Страница 3: ...e Alarm 26 Tamper Recognition 26 Keypad Panic Options 27 Panic Lockout Timer 27 Reporting and Dialer settings 28 Reporting Dialer Enable Disable 29 Report Codes 29 Central Station Telephone Numbers 31...

Страница 4: ...nsmission and Recent Closing Report Regular Arming Stay Arming Instant Arming Force Arming One Touch Arming Auto Arming or Keyswitch Arming 256 Event Buffer with time stamp Telephone Line Supervision...

Страница 5: ...2 2 on page 4 For UL installations the metallic enclosure must be grounded to the cold water pipe 2 3 AC POWER Do not use any switch controlled outlets to power the transformer Connect the transformer...

Страница 6: ...AC Power and Backup Battery Connections on page 3 To connect the 5A Alarm Relay and the PGMs refer to Relay and PGM Connections on page 6 To connect AC power refer to AC Power and Backup Battery Conne...

Страница 7: ...Bell Disconnected failure will remain in the keypads Trouble Display see page 42 To avoid this connect a 1K resistor across the BELL terminals 2 8 PROGRAMMABLE OUTPUT CONNECTIONS When a specific event...

Страница 8: ...trol panel remove the back cover and wire the GRN YEL RED and BLK terminals of each keypad to the corresponding terminals on the control panel as shown in Figure 2 2 on page 4 There is no limit to the...

Страница 9: ...or by activating a switch with a key Connect the keyswitch as shown in Figure 2 6 directly to the control panel terminals Once a keyswitch is connected it must be assigned to a zone and its parameters...

Страница 10: ...sections 001 to 016 126 to 138 and 302 to 348 each option from 1 to 8 represents a specific feature or option Press the key corresponding to the desired option and the corresponding light will illumin...

Страница 11: ...hen key 2 is OFF not illuminated EOL is disabled and the keypad zone will use the on board EOL resistor When key 2 is ON illuminated EOL is enabled and the keypad zone requires that an external EOL re...

Страница 12: ...ory Key PMC 3 Then copy the contents of the Memory Key into as many Spectra control panels as needed Each panel is programmed in less than 3 seconds Download to DESTINATION Control Panel 1 Remove AC a...

Страница 13: ...s The System Master Code can be 4 or 6 digits in length Access Code Length on page 11 where each digit can be any digit from 0 to 9 To change the System Master Code press ENTER INSTALLER CODE 301 new...

Страница 14: ...is dependent on the other User Code Options selected Please note that with the Arm Only option the user can cancel a recently armed system by re entering the access code before the end of the Exit Del...

Страница 15: ...to the same expansion input 5 2 REASSIGN KEYPAD ZONE 2 Section 126 General Options Option 7 OFF Reassign Keypad Zone 2 Disabled default Option 7 ON Reassign Keypad Zone 2 Enabled Reassign Keypad Zone...

Страница 16: ...s partition assignment and how the control panel will react when an alarm condition occurs on that zone These Zone Parameters are programmed into one section as detailed in Figure 5 1 on page 15 Only...

Страница 17: ...e a different Entry Delay 5 5 2 ENTRY DELAY 2 Sections 001 to 015 Zones 1 to 15 First Digit 2 Entry Delay 2 zones are identical to the Entry Delay 1 zones see section 5 5 1 except it uses a separate E...

Страница 18: ...5 6 EXCLUSIVE ZONE DEFINITIONS The following three zone definitions can only be used for devices connected directly to the control panel s on board input terminals When a zone is programmed as a Keys...

Страница 19: ...S ZONES Sections 001 to 015 Zones 1 to 15 Option 2 OFF Bypass Zone Disabled Option 2 ON Selected Zone is Bypass Enabled default When a user utilizes the Bypass Programming feature see page 45 only zon...

Страница 20: ...5 Option 8 OFF Force Zone Disabled default Option 8 ON Selected Zone is Force Enabled Any open Force Zones at the time of arming will be considered deactivated by the control panel see page 45 If duri...

Страница 21: ...re proper synchronization between the control panel and the transmitter open and close the zone corresponding to the transmitter 6 1 2 DELETING ASSIGNED WIRELESS TRANSMITTERS Sections 601 to 608 6 1 3...

Страница 22: ...ignal within a specified time period as programmed in Check in Supervision Timer Settings on page 21 to confirm their presence and functionality If a device has not sent a signal within that time peri...

Страница 23: ...ore information refer to Wireless Transmitter Low Battery Supervision on page 40 6 5 REMOTE CONTROL PROGRAMMING The Spectra 1759EX accepts up to eight fully programmable remote controls Programming th...

Страница 24: ...ned to sections 731 to 738 refer to Assigning a Remote Control to the Spectra 1759EX on page 21 For example the buttons for the remote control assigned in section 731 will be programmed in section 711...

Страница 25: ..._ ____ ____ A B C D A B C D A C B D Remote Control 4 715 ____ ____ ____ ____ ____ ____ ____ ____ A B C D A B C D A C B D Remote Control 5 716 ____ ____ ____ ____ ____ ____ ____ ____ A B C D A B C D A...

Страница 26: ...feature allows users to Force arm without pressing the FORCE key before entering their User Access Code Force arming cannot be done using a keyswitch Force arming is not supported by keyswitches 7 4 R...

Страница 27: ...terval of time without movement you wish the control panel to wait before arming and or sending the No Movement report code If No Movement Auto Arming is disabled the control panel can still send the...

Страница 28: ...Option 5 ON No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled With this feature enabled the control panel will prevent the bell or siren from squawking and the keypads from beeping duri...

Страница 29: ...F Emergency Panic Disabled default Option 1 ON Emergency Panic Enabled Press the 1 and 3 keys simultaneously on the keypad for 2 seconds to generate a silent or audible alarm as defined by option 4 Op...

Страница 30: ...Codes Option 6 ON Call Telephone 2 for Tamper Restore Report Codes Section 138 Option 1 ON Call Telephone 1 for Trouble Restore Report Codes Option 2 ON Call Telephone 2 for Trouble Restore Report Cod...

Страница 31: ...ARMING A partition has armed itself at the programmed time see page 24 LATE TO CLOSE Reports every day at the time specified by the Auto Arm Timer see page 25 NO MOVEMENT A partition has armed itself...

Страница 32: ...T CODES Sections 201 to 204 A report code can be programmed for each of the 15 available zones Whenever a tampered zone is restored the control panel can send the appropriate report code to the centra...

Страница 33: ...these telephone numbers are used please refer to Event Call Direction on page 33 and Reporting Formats on page 31 After the Maximum Dialing Attempts see page 34 to one central station telephone numbe...

Страница 34: ...trol panel will automatically generate Contact ID Report Codes for every event in sections 160 to 213 Refer to the All Codes Ademco Contact ID Report Code List in the Spectra System Programming Guide...

Страница 35: ...ption 3 is off and option 4 is on in section 137 the control panel will attempt to communicate with Central Station Telephone Number 2 in order to transmit the Zone 1 Alarm Report Code programmed in s...

Страница 36: ...generated within the period defined by the Recent Close Delay the control panel will attempt to transmit the Recent Close report code programmed in section 195 9 16 AUTO TEST REPORT Sections 087 000 D...

Страница 37: ...e for the duration of this period the control panel will generate the condition s defined by the TLM options see above PART 10 PROGRAMMABLE OUTPUTS A PGM is a programmable output that toggles to its o...

Страница 38: ...t has occurred in the system You can program each PGM output to be normally open N O or normally closed N C by enabling or disabling options 4 5 and 6 in section 126 Option 4 OFF PGM1 Normally Closed...

Страница 39: ...Charge Current 350mA default Option 5 ON Battery Charge Current 700mA 40VA transformer required 11 5 PARTITIONING Section 127 General Options Option 1 OFF Partitioning Disabled default Option 1 ON Pa...

Страница 40: ...el will send the Zone Tamper report code as originating from partition 1 A Tamper Zone Wiring Failure will also appear in the keypads Trouble Display see page 42 When Reassign Keypad Zone 2 is enabled...

Страница 41: ...ith the APR prefix are compatible with Spectra versions 2 0 and higher and Digiplex Modules with the APR3 prefix are compatible with Spectra versions 2 0 and higher Digiplex and DigiplexNE 11 13 PRINT...

Страница 42: ...panel will follow the zone s Alarm Types setting see page 17 7 ON 8 ON Audible Alarm When a tamper occurs on an Omnia wireless transmitter zone in a disarmed system it functions the same as the Troubl...

Страница 43: ...rings This value represents the number of rings the control panel will wait before picking up the line If the line is not answered after the number of programmed rings the control panel will answer t...

Страница 44: ...lls back Please note that the PC Telephone Number must be programmed in section 150 in order to use the Call Back feature PART 13 USER OPERATION 13 1 TROUBLE DISPLAY The Spectra system continuously mo...

Страница 45: ...communicate with the central monitoring station 8 Timer Loss The control panel s internal clock must be re programmed To re program the timer press the 8 key followed by the current time using the 24...

Страница 46: ...MASTER CODE or MASTER CODE 3 Key in 3 digit SECTION see Table below 4 Key in new 4 or 6 digit ACCESS CODE ENTER flashes Return to step 3 How Do I Delete Access Codes 1 Repeat steps 1 to 3 see above 2...

Страница 47: ...ust have the Force Arming Option enabled 13 8 MANUAL BYPASS PROGRAMMING Manual Bypass Programming allows users to program the alarm system to ignore deactivate specified zones the next time the system...

Страница 48: ...Press and hold keys 1 and 3 for a panic alarm Press and hold keys 4 and 6 for a panic or medical alarm Press and hold keys 7 and 9 for a panic or fire alarm 13 12 AUTO ARMING NOT TO BE USED WITH UL IN...

Страница 49: ...ation Beep All other beep functions are disabled 13 16 KEYPAD BACKLIGHT 1686H and 1686V Only The illumination level behind the keys can be modified to suit the user s needs There are four backlight le...

Страница 50: ...munications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to equipment intermittently the user is encour...

Страница 51: ...circuit boucl peut tre constitu e de n importe quelle combinaison de dispositifs pourvu que la somme des indices de charge de l ensemble des dispositifs ne d passe pas 100 La certification d Industri...

Страница 52: ...tion 5 Bell Squawk On Arm Disarm With Keypad 26 Bell Squawk On Arm disarm with Remote Control 26 Burglary Zones 24 Hr 16 Buzzer Zone 16 Bypass Options Supervision 40 Bypass Programming 45 Bypass Recal...

Страница 53: ...rming On Battery Fail 24 No Arming on Supervision Loss 40 No Arming On Tamper Trouble 24 No Audible Feedback Upon Stay Arming 26 No Exit Delay When Arming with Remote Control 26 No Movement Auto Armin...

Страница 54: ...ne Line Connection 5 Telephone Line Monitoring TLM 35 Telephone Number PC 41 Telephone Numbers 31 Test Report Automatic 34 Test Report Manual 39 Timed Auto Arming 24 Transformer Requirements 3 Transmi...

Страница 55: ......

Страница 56: ...to Friday 8 a m to 8 p m EST Technical support can also be reached by fax at 450 491 2313 or via e mail at support paradox ca 780 Industriel Blvd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444...

Отзывы: