9
If you do not have adequate space to install the feed pump inlet module it is possible to re-
move and relocate the feed pump. Before you install the module, disconnect the hose that
connects the feed pump to the module plumbing. Remove the cooling fan and the heat sink
from the pump. Both are friction fits with no fasteners. Remove the 4 machine screws hold-
ing the pump to the module.
Feed Pump Relocation
Cooling fan
Heat sink
With the pump on a flat surface. Remove the three
screws that hold the pump head on.
See Fig1
Re-orient the pump head 120 degrees.
See Fig2
Reinstall the screws and tighten firmly.
See Fig3
Now the feed pump may be installed where you wish.
Do not install with the pump head over the motor in-
case of leaks. Wire size may have to be increased if
wire runs are longer.
Fig 1
Fig 2
Fig 3
Machine Screws