8
Water Flow
Sea Strainer,
Mount with
Quick Block
Ventura 150 MPC Plumbing
Inlet pump module
. Mount vertically as low as prac-
tical, no more than 4’ (1.1 M) above waterline and do
not mount over electrical equipment.
Leave clearance below for filter change.
20 and 5 micron filters
. Do not mount
over electrical equipment. Leave clear-
ance underneath for filter change
Accumulator,
Factory
pre-charged. Install so
that gauge is visible.
Plastic fittings should have 3-4 wraps of Teflon
tape and will thread almost all the way in. Leave
the first pipe thread uncoated. Avoid getting dirt
or debris in the system during assembly. Avoid
tight bends and elbows. Secure piping away from
moving objects and protect from chafe.
Fresh water
flush inlet to charcoal
filter. Plumb to pressure side of
fresh water system.
Spectra Clark Pump
. Mount in a cool location. May
be oriented in any position and can be well above
waterline. Leave access to the pressure relief valve.
Do not mount over electrical equipment. Use supplied
spacers and washers for the vibration mounts.
Brine Discharge
thru hull place
above waterline or tee brine into
another visible drain.
1/2” or 3/4” scoop strainer thru-hull and seacock for
watermaker only. Mount low, in a clear flow and away
from head discharge. Thru-hull is owner supplied.
Red In
Green Out