11
Plumbing
From the inlet thru hull to the boost pump module and from the boost pump module to pump
module inlet use supplied clear 3/4 (19mm) spiral suction rated hose. The outlet of the filter
assembly on the main module to the Clark pump assembly is under pressure. Use the sup-
plied braided clear vinyl hose rated to 150 PSI (11 bar). From Clark pump brine discharge
connector use supplied 5/8 (15.9mm) clear braided vinyl hose.
On the feed pressure side use the supplied Parker 1/2 tube and fittings. Use two grab rings on
the 1/2 parker tubing. Refer to the parker assembly instructions.
The remote control panel can be mounted anywhere
that’s dry and convenient. Cut a 4-9/16” (116 mm) wide
by 2-7/8” (68mm) high opening for the panel. Locate in
an area that is easily visible and easy to manipulate the
buttons.
Use only Spectra approved remote cable.
The cable is not standard LAN cable or phone cord.
Remote Control Panel
!! Route all hoses and tubes to prevent kinks and restrictions. Se-
cure piping away from moving objects such as engine belts and
hatches. Prevent chafe on tubing as required. Test and inspect all
piping and hose clamps after several hours of operation.