New System Start-Up and Testing
Avoid running the system if the vessel is in contaminated water, such as in a harbor or canal.
The system should be fully run tested before leaving port. It is preferable to sacrifice a filter by
running the system in turbid water rather than waiting to get offshore to discover a problem or
deficiency in the installation. If the location or weather prevents proper testing refer to the sec-
tion “Dry Testing.”
1. First Check That:
•
Thru-hull valve is open
•
Manual / auto switch in “Auto” position
•
Domestic fresh water pressure system
must be on
2. Open pressure relief valve
1
/
2
turn
3. Power up the system
•
Alarm will sound
•
Push the “Alarm/Display” button to
silence alarm
Warning! Damage may occur if the purge sequence is bypassed and the membrane is
pressurized with storage chemical in it.
Содержание CATALINA 300 MPC-5000