15
Product water to
tank
Diversion Valve Solenoid
Brine Discharge
Route the Brine discharge from the
quick disconnect fitting to a location
above the waterline using the
supplied
5
/
8
(15.9 mm) hose.
Quick Disconnect Fitting
Product Water tubing
Product water tubing is
1
/
4
”
(6.3 mm) Parker tubing.
See the Parker tube fitting assembly
diagram next page
.
Product water is pre-plumbed from the membrane into the electric diver-
sion valve. The diversion valve will reject product water into the overboard brine stream un-
til good quality is measured by the MPC-5000 control. Product water is then diverted into
the fresh water tank. The salinity probe must be mounted in a vertical position with the ca-
ble coming out the bottom. If the Clark Pump/Membrane Assembly is mounted vertically
or upside down the Diversion Valve/ Probe Assy should be remounted.
You will need to route the product water from the valve into the top of the tank. Install
a tee in the water fill or tap a pipe thread into an inspection port in the top of the tank.
Do not feed the water into a manifold or bottom of the tank. Make sure there is no re-
striction in this plumbing.
RotoFlow Meter
Salinity Probe