4
Applications
88
Spectra Precision Focus 6 5" Total Station User Guide
4.
Enter offsets to the line.
Press
[ENT]
in a blank field to enter the value 0.0000.
5.
Rotate the instrument until the dHA is close to
0°00'00".
6.
Sight the target and press
[MSR1]
or
[MSR2]
.
When a distance measurement is taken, the
difference from the design point appears.
7.
To record the point as an SO record, press
[ENT]
.
Using
[DSP]
to switch between display screens
You can use
[DSP]
to switch between display screens. This function works as in the
angle-distance stakeout. For more information, see
.
Program Key
To display the Programs menu, press
[PRG]
.
Measuring distance and offset values along a specified line
1.
Press
[1]
or select
2Pt RefLine
in the Programs
menu.
2.
Enter the first point for the reference line.
Alternatively (to enter the point by measuring),
press the
MsrPT
softkey.
Sta
Distance from P1 along the line
O/S
Distance perpendicular to the line
(+)
Right side of the P1-P2 line
(-)
Left side of the P1-P2 line
dZ
Difference in height from the line
Содержание Focus 6
Страница 1: ...Spectra preciSion 6 5 TOTAL STATION...
Страница 2: ...Blank page Inside cover...
Страница 3: ...Version 1 00 Revision A October 2009 User Guide Spectra Precision Focus 6 5 Total Station...
Страница 6: ...4 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 12: ...Safety 10 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 24: ...1 Introduction 22 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 111: ...Spectra Precision Focus 6 5 Total Station User Guide 109 Applications 4 CO O S MSR 83 1 5555 76 5518 62 08380 81 06510...
Страница 112: ...4 Applications 110 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 170: ...7 Specifications 168 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 174: ...8 System Diagrams 172 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 190: ...9 Communications 188 Spectra Precision Focus 6 5 Total Station User Guide...