Spectra Precision Focus 6 5" Total Station User Guide
85
Applications
4
Note –
To switch between display screens, press
[DSP]
. This function works as in the angle-
distance stakeout, except that the screen counter ( for example, S-O1/8) is not displayed.
For more information, see
Using [DSP] to switch between display screens, page 83
.
Note –
Once a measurement is taken, the Cut/Fill value and Z coordinate are updated as
the VA is changed.
6.
To record the point, press
[ENT]
. PT defaults to the
specified PT + 1000.
Note –
Use the Add Constant field in
MENU >
Settings > Stakeout
to specify an integer that is
added to the point number being staked to generate a new
number for recording the staked point. The default value
is 1000. For example, when you stake out PT3 with an Add
Constant of 1000, the default number for SO record is
1003. For more information, see
.
After recording the point, the display returns to the
observation screen. When you press
[ESC]
, the display
returns to the PT/CD/R input screen. If you entered the
stakeout point using a single point name, the PT
defaults to the last PT + 1.
If you selected a point from the list, the display returns
to the list, unless all points have been selected. Press
[ESC]
to return to the point input screen.
Advanced feature: Specifying a stakeout list by range input
1.
To input points by range, press the
Fr/To
softkey
in the PT field.
2.
Enter the start point (Fr) and the end point (To).
The range between Fr and To must be less than
1001 points.
Содержание Focus 6
Страница 1: ...Spectra preciSion 6 5 TOTAL STATION...
Страница 2: ...Blank page Inside cover...
Страница 3: ...Version 1 00 Revision A October 2009 User Guide Spectra Precision Focus 6 5 Total Station...
Страница 6: ...4 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 12: ...Safety 10 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 24: ...1 Introduction 22 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 111: ...Spectra Precision Focus 6 5 Total Station User Guide 109 Applications 4 CO O S MSR 83 1 5555 76 5518 62 08380 81 06510...
Страница 112: ...4 Applications 110 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 170: ...7 Specifications 168 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 174: ...8 System Diagrams 172 Spectra Precision Focus 6 5 Total Station User Guide...
Страница 190: ...9 Communications 188 Spectra Precision Focus 6 5 Total Station User Guide...