Spectra Logic Spectra 12K Скачать руководство пользователя страница 1

Entry/Exit Port Slider
Replacement Guide

• Spectra

®

 12K Library

• Spectra

®

 64K

 

Library

Содержание Spectra 12K

Страница 1: ...Entry Exit Port Slider Replacement Guide Spectra 12K Library Spectra 64KLibrary...

Страница 2: ...e However no responsibility is assumed by Spectra Logic for its use Due to continuing research and development Spectra Logic may revise this publication from time to time without notice and reserves t...

Страница 3: ...ts Introduction 4 Prepare the Library and Host System 6 Remove the Robotic Rack Assembly 7 Remove the Spectra E E Port Slider 13 Replace the E E Port Slider 18 Replace the Robotic Rack Assembly 20 Pre...

Страница 4: ...t E E port slider in Spectra 12K and Spectra 64K libraries and how to test the assembly after it has been installed About the E E Port Slider The E E port slider enables the E E port to move in and ou...

Страница 5: ...ssembly P N 90919043 top or E E port slider assembly P N 90910044 bottom You will also need the following tools A 1 Phillips screwdriver A 2 Phillips screwdriver A 3 32 inch hex wrench A 2 5 mm hex wr...

Страница 6: ...at the rear of the library on the lower left It is necessary to unlock and open the rear door of Spectra 64K libraries 3 If necessary move the library to a location where you have full access to the f...

Страница 7: ...ort Slider Replacement Guide 7 Remove the Robotic Rack Assembly 1 Lower the transport tray to bottom of the robotic rack by gently raising the counter weight Figure 2 Figure 2 Theroboticrackcounterwei...

Страница 8: ...aces the rear of the library The location of the bar code scanner is shown in Figure 3 3 Slide the picker along the transport tray to the front of the library Figure 4 Figure 3 The locationofthebar co...

Страница 9: ...have a hinge Figure 6 proceed to Step 6 5 Using the appropriate screwdriver loosen the screws just enough to move the gate out of the way from the robotic rack assembly Figure 7 Some Spectra 12K libra...

Страница 10: ...8 7 Using the 2 Phillips screwdriver loosen the screws that hold the robotic rack assembly to the chassis first the top three screws then the bottom two Figure 9 Figure 8 The25 wire black connector Sp...

Страница 11: ...brary models have only four screws attaching the robotic rack to the chassis 8 From the front of the library carefully slide the robotic rack assembly outward about six inches 15 24 cm Figure 10 Figur...

Страница 12: ...rack assembly from the library Figure 11 and Figure 12 10 Set the robotic rack assembly aside on a level surface away from traffic and the library Figure 11 Theroboticrackassembly beingliftedoutofthel...

Страница 13: ...ottom E E port is located on the bottom of that E E port Only remove the E E port motor that is attached to the slider you are replacing 1 Make sure the E E port door is closed 2 Disconnect the E E po...

Страница 14: ...Support at 800 227 4637 or 303 449 0160 Inform the support representative that you are installing an E E port motor in a Spectra 12K or Spectra 64K library and your E E port motor has four screws atta...

Страница 15: ...if you are replacing the bottom slider Note Remove the magazine closest to the E E port first Make a note of where each magazine location They will need to go back in the exact same location from whe...

Страница 16: ...ss some of the screws as shown in Figure 19 9 Using a flat head screwdriver remove the Stop that keeps the E E port from sliding all the way out Figure 20 but do not remove the slider yet Caution Do n...

Страница 17: ...Entry Exit Port Slider Replacement Guide 17 10 Carefully remove the E E port and slider while holding on to both parts as illustrated in Figure 21 Figure 21 Carefully remove theE E portand slider...

Страница 18: ...the slider The slider is equipped with ball bearings that may fall out if the slider and E E port are removed separately 3 Replace the five screws that hold the slider in place using the same method...

Страница 19: ...and forth to ensure a smooth motion If the motion is not smooth return to Step 1 and repeat the procedure Figure23 TheE EportmotorscrewsandtheECnumber circled Spectra 12Klibraryshown Figure 24 The E...

Страница 20: ...ck Assembly 1 Carefully place the robotic rack assembly into the library Figure 27 and Figure 28 Figure 27 Theroboticrack assemblybeingplaced in the library Spectra 12Klibrary shown Figure 28 Therobot...

Страница 21: ...igure 29 3 Using the 2 Phillips screwdriver tighten the screws that hold the robotic rack assembly to the chassis first the bottom then the top Figure 30 Figure 29 Therobotic rackassembly ismoved allt...

Страница 22: ...ng the left drive slots to the back of the library proceed to Prepare the Library for Tests on page 23 Otherwise proceed to Step 5 5 Using the appropriate screwdriver tighten the screws that hold the...

Страница 23: ...hen moving the library The Spectra 12K library weighs approximately 175 lbs The Spectra 64K library weighs approximately 880 lbs 4 Switch on AC power at the rear of the library The library initializes...

Страница 24: ...he Available Tests list select Install New Picker Figure 33 6 Select Prepare Test 7 From the Diagnostics Configuration window select Run Test there are no parameters for this test 8 Once the picker ha...

Страница 25: ...it Port window displays select OK 5 Insert any bar coded tape into Slot 1 the top slot of the DCM in the E E port 6 Select Open Close again to close the E E port 7 The Confirm Close Entry Exit Port wi...

Страница 26: ...h first and fifteenth slot loads correctly The tape will be returned to the E E port when the test is completed Note This test takes a long amount of time to complete It could take up to an hour in a...

Страница 27: ...new slider to package and send the old E E port slider assembly back to Spectra Logic 2 Secure the box closed with packaging tape and clearly label it for return to Spectra Logic at the following addr...