background image

 

Speco Technologies® 0106  SG-WR150 

1

®

 

 

Speco Technologies weatherproof ruggedized keypad (SG-WR150)

 is designed to meet most 

residential, commercial and industrial single door access control requirements. The electronics 
reside in this self-contained unit. The SG-WR150 is a weatherproof indoor/outdoor surface mount 
device. This rugged keypad comes with its own tamper resistant box. 
 

Key Features: 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Indoor/Outdoor surface mount application 

 

Self contained electronics package 

 

Includes metal weatherproof tamper 
resistant box 

 

12 Braille keys 

 

Sounder 

 

130 users 

 

Input trigger for request to exit 

 

3 independent relay outputs (5A/250V AC) 

 

Adjustable time relay of up to 99 seconds 
for each relay output or latched 

 

Rank/Code program administration 

 

Each output is assignable by code 

 

Codes can range from 3 to 6 digits 

 

Unit shuts down for 20 seconds after 
entering 3 incorrect codes 

 

Master code can shut down all others as a 
temporary lock-out 

 

Visual/Audible function confirmation 

 

Tamper switch 

 

12/24 Volt – AC/DC operation 

 

Codes 

The Speco Technologies architectural backlit keypad 
allows up to 130 user codes, of 3 to 6 digits in length, 
to be programmed. 

 

The master code and user codes must be the 
same length. 

 

Available ranks are from 001-129 and ranks 
are all 3 digit values. 

 

0-9 are valid digits for user codes, but ‘ * ’ or   
‘ # ’ is not allowed to be used in a user or 
master code. 

 

By default, a valid user code activates output 
1 if not defined. 

 

Hardware (jumper) reset is provided by the 
master code. 

 

Can assign up to two outputs per code. 

 

Each user code must be different. Trying to 
enter the same code twice will generate an 
error. 

 

The Master code is strictly reserved for 
configuration and cannot be used to operate 
an output. 

 

All parameters are saved on EEPROM. 

 

A valid user code needs to be followed by 
the 

*

 key.

 

Programming 

All programming is done from the front of the 
keypad. LED/Sounder guidance helps to make 
programming easy and authorized users can 
change codes in seconds. 

 

Key Press Visual/Audible 
Feedback 

The orange LED blinks and a beep is heard 
when a key is pressed. The sounder can be 
deactivated by programming for user code 
entries (function 60). 

 

Memory 

EEPROM non-volatile memory means your 
programming is safe. The codes and 
instructions will still be there anytime power is 
removed. 
 

Keypad Lockout 

 

If needed, every programmed user’s 
code can be disabled without deleting 
them. This is achieved by using 
function 90 ‘Keypad Lockout ON’ 

 

When ‘Keypad Lockout’ is active, any 
‘Request To Exit’ devices connected 
on the EXIT SW input will still activate 
relay one to allow exiting. 

 

When ‘Keypad Lockout’ is active, the 
master code (MC) will only activate 
output one. Activation time of output 
one is the time configured in rank 000 
which is also the time used for 
‘Request To Exit’ function. 

Instruction Manual 

Weatherproof Ruggedized Keypad 

SG-WR150 

Содержание SG-WR150

Страница 1: ...not allowed to be used in a user or master code By default a valid user code activates output 1 if not defined Hardware jumper reset is provided by the master code Can assign up to two outputs per code Each user code must be different Trying to enter the same code twice will generate an error The Master code is strictly reserved for configuration and cannot be used to operate an output All paramet...

Страница 2: ...Main PC board in place The green LED will turn ON and one beep will sound The master code will return to the factory setting 1234 and the code length will return to 4 digits Remove the jumper to return to normal operation Selection of Outputs by User Code It is possible to select one or two outputs for each user code This is done by entering a two digit value in the first field of function 52 Some...

Страница 3: ...1 G1 G1 32 rank code code G1 G1 G1 Adding or editing a user code R E T U R N T O M A I N M E N U Adding or editing a user code with timer value for output 1 33 time rank code code G1 G1 G1 G1 G1 M A I N M E N U 34 rank G1 G1 Disabling a user code 40 12345 12345 G1 G1 G1 Unit entire reset Output activation 2 digits selection per user code 52 01 or 23 or rank code code G1 G1 G1 G1 G1 60 1 G1 G1 Buzz...

Страница 4: ...E This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause ha...

Отзывы: