Installation
04/2019 EN
21
5 Installation
5.1 Installation
site
5.1.1 Installation
surface
The installation surface must be level and horizontal in order
to avoid damage.
Observe
weight
indications!
5.1.2 There
must
be ground drainage
Calculate the size of the ground drain according to the
following criteria:
– Size of the swimming pool.
– Circulation
flow
rate.
5.1.3 Ventilation and aeration
Ensure sufficient ventilation and aeration. The ventilation and
aeration must ensure the following conditions:
– Prevention
of
condensation.
– Cooling of the pump motor and other system components,
for example switch cabinets and control units.
– Limitation of the ambient temperature to maximum 40 °C.
5.1.4 Structure-borne and airborne noise transmission
Observe regulations for structural noise protection, for
example DIN 4109.
Install the pump in a manner which reduces structure-borne
and airborne noise transmission. Vibration-absorbing
materials are suitable bases. Examples:
– Anti-vibration buffers (Normblock Multi)
– Cork
lining
– Sufficiently
hard
foam
5.1.5 Reserve
space
Calculate the reserve space to allow the motor unit to be
removed in the direction of the motor fan with the help of
lifting equipment and the strainer basket to be removed from
the front.
5.1.6 Fasteners
Fasten pump using screws.