Faults
18 EN
06|2019
6 Faults
Problem:
Pump doesn’t run.
Possible cause
Solution
No voltage.
Check the fuse and other
protective devices.
Thermal motor protection
triggered.
Wait for the motor
winding to cool down and
the motor protection to
turn back on.
Problem:
No flow rate; motor turns.
Possible cause
Solution
Insufficient fluid level.
Ensure the pump is
completely submerged.
Problem:
Pump stops automatically.
Possible cause
Solution
Voltage error.
Ensure that the voltage
on the name plate
corresponds to the
voltage indicated.
Thermal motor protection
triggered.
Wait for the motor
winding to cool down and
the motor protection to
turn back on.
Insufficient fluid level.
Close tap to reduce the
pump’s flow volume.
Problem:
Too low a flow rate in the pump.
Possible cause
Solution
Insufficient fluid level.
Close tap to reduce the
pump’s flow volume.
Strainer basket is clogged.
Clean
the
strainer
basket.
Wear to the hydraulic system.
Contact
customer
services.
Содержание Zismatic 40/10 WE
Страница 3: ...DE DE Originalbetriebsanleitung Zismatic 40 10 WE WG64 005 001 P...
Страница 13: ...Sicherheit 06 2019 DE 11 H max 333 min 111 Q max 333 min 111 A B C 230V C 0 OFF CHEMICALS WG64 011 001 P Abb 1...
Страница 28: ......
Страница 29: ...EN EN Translation of original operation manual Zismatic 40 10 WE WG64 005 001 P...
Страница 53: ......
Страница 54: ......
Страница 55: ......