Installation
06|2019 EN
13
4 Installation
4.1 Installation
4.1.1 Installation
in
wells
The pump may not be placed or installed on the ground of the
well. In order to avoid this, the pump should be fastened to a steel
cable during installation.
The pump may not, under any circumstances, be lifted on the
electrical connection cable and pressure line.
The pump must remain completely under water in order to ensure
sufficient cooling.
35 °C
max.
max. 12m
WG64.012.001-P
Fig. 2
4.1.2 Water
quantity
The water quantity in the well must be greater than that required
by the pump. This will prevent the pump running dry or starting up
too frequently and then turning off again.
Содержание Zismatic 40/10 WE
Страница 3: ...DE DE Originalbetriebsanleitung Zismatic 40 10 WE WG64 005 001 P...
Страница 13: ...Sicherheit 06 2019 DE 11 H max 333 min 111 Q max 333 min 111 A B C 230V C 0 OFF CHEMICALS WG64 011 001 P Abb 1...
Страница 28: ......
Страница 29: ...EN EN Translation of original operation manual Zismatic 40 10 WE WG64 005 001 P...
Страница 53: ......
Страница 54: ......
Страница 55: ......