background image

 Inhaltsverzeichnis 

05/2013 VG 

766.2330.061 

EN 

35

 

EN 

Original Operating Instructions for 

 

BADU

®

Jet

BADU

®

Jet

BADU

®

Jet

BADU

®

Jet

 

 

Содержание BADU Jet Perla

Страница 1: ...Inhaltsverzeichnis 05 2013 VG 766 2330 061 EN 35 EN Original Operating Instructions for BADU Jet BADU Jet BADU Jet BADU Jet ...

Страница 2: ...ating Parts 42 2 7 3 Electrical Power 42 2 7 4 Hot Surfaces 43 2 7 5 Entrapment Hazard 43 2 7 6 Entrapment Hazard of sensitive body parts 43 2 8 Malfunctions 43 2 9 Prevention of Material Damage 44 2 9 1 Leakage and Burst Pipes 44 2 9 2 Protection against Running Dry 44 2 9 3 Overheating 44 2 9 4 Seized Pump 44 2 9 5 Drainage 44 2 9 6 Frost protection 45 3 Description 46 4 Transport and Interim St...

Страница 3: ...7 1 2 Air Regulation Function 53 7 1 3 Light operation 53 7 1 4 Setting the ball nozzle 53 7 1 5 Cover damage 53 7 1 6 Optimal water level 53 7 2 Massage hose 54 7 2 1 Instructions for the massage hose 54 7 2 2 Air regulation and the massage hose 54 8 Malfunctions 55 8 1 Failures 55 8 1 1 Overload switch has triggered 56 9 Maintenance Service 57 9 1 Care Instructions 57 10 Appendix I 58 10 1 Techn...

Страница 4: ... this manual This also applies in cases of carelessness during the installation procedure use and maintenance of the product Non compliance with the safety instructions can jeopardize the safety of personnel the environment and the product itself Non compliance with the instructions will also lead to forfeiture of any and all rights to claims for damages Keep the instructions available for the lif...

Страница 5: ...ere injury CAUTION Physical Danger Non observance can result in per sonal injury Instructions to prevent material dam age and optimize operation To ensure easy and correct operation important technical information in a step by step procedure have been highlighted Symbol Meaning Single step action 1 2 Multi step action Follow the sequence of steps ...

Страница 6: ...be exceeded These instructions should be followed closely since the counter swim units are subject to special requirements 2 1 1 Possible Misuse The unit is not properly secured The system has not been completely filled with water Opening and maintenance of the unit by unqualified personnel 2 2 Precautions and Qualifications The overhang counter swim unit is not intended to be used by persons incl...

Страница 7: ...s and guidelines When operating the overhang counter swim unit the following safety guidelines must be observed These instructions Warning and signs affixed to the product Other applicable documents The relevant national regulations for accident prevention Local safety regulations and internal company guidelines 2 4 Protective Cover Reaching into moving parts e g coupling can cause severe injury O...

Страница 8: ...completion of the work all safety relevant and protective devices must be re installed and or re activated 2 7 3 Electrical Power During work on the electrical system there is an elevated danger of shock due to the moist environment Improper installation of the electrical earth protection wire can lead to shock e g through oxidation or cable breakage Hazards resulting from electricity are to be pr...

Страница 9: ...e fitted clothing To avoid hair entanglement uses a bathing cap Suction openings should be checked and cleaned regularly 2 7 6 Entrapment Hazard of sensitive body parts Intake nozzles and massage equipment move large volumes of water and operate at high pressure and high flow speeds This can lead to serious injury to the eyes and other sensitive body parts such as severe intestinal damage or evisc...

Страница 10: ...parts within seconds Never let the pump run dry not even when checking for the direction of rotation Ventilate the pump and the suction line before starting up 2 9 3 Overheating The following factors may lead to the pump overheating Improperly set motor protection switch Air vents are blocked by leaves branches etc Lack of separation wall Ensure the external or built in overload switch is correctl...

Страница 11: ...766 2330 061 EN 45 2 9 6 Frost protection If there is a danger of frost during prolonged idle periods the pump and all pipes must be drained ahead of time During winter the unit must be emptied and stored in a dry location ...

Страница 12: ...r 7 Cover 2 Light ON OFF 41 Light Protection cover 3 Unit ON OFF 54 1 Ball nozzle Function The overhang counter swim unit draws water from the swimming pool via a suction line which is then injected back into the swimming pool under high pressure via the pressure line through the ball nozzles ...

Страница 13: ...e temperatures are as con stant as possible 4 1 Lifting the counter swim unit WARNING Death or injury can occur through falling parts during transport The motor suspension rings are intended for the weight of the motor only and are not designed to hold the weight of a complete overhang counter swim unit as the suspension rings may break out The device is to be mounted on the base plate Only use su...

Страница 14: ...markings 5 1 5 Insert the brass dowels Insert brass dowels 25 and screw on the vibration rubber metal buffer 26 see page 63 figures 7 and 8 Make sure that the bolts with the buffers are securely anchored in the base so that the unit sits securely 5 1 6 Secure the unit Set the unit on the vibration buffers and secure it with the hexagonal bolts 32 toothed lock washers 31 and flat washers 30 See pag...

Страница 15: ...its protective area must be in accordance with DIN VDE 0100 702 A disconnecting device has to be installed to cut off the power sup ply contact opening according to the conditions of the overvoltage category III WARNING Voltage on the housing may cause electric shock Set the motor protection overload switch settings Take the values on the type plate into consideration Protect the electric circuit ...

Страница 16: ...ch in accordance to DIN EN 809 must be provided for 5 4 Additional parts required The following parts are not included with the unit and must be provided for before installation on site Earth leakage switch I N 30 mA Fuse 16 A slow blow 230 V and 400 V Emergency switch disconnects all phases ...

Страница 17: ...red to remove it When replacing the cover make sure that the key snaps snugly into place over the position switch Do not use force 2 Using the hand pump included attached to the base plate ventilate the unit as follows See page 66 figure 11 Attach the tube of the hand pump to the air drain valve on the pump Turn the air drain valve anti clockwise to open Pump until water flows out Close the air dr...

Страница 18: ...in the direction of rotation 6 3 Switching ON Prerequisites Unit must be filled with water Cover on Running dry will damage the pump Ventilate the pump and the suction line 4 Switch the unit on If the pump in the unit has a three phase motor and is running in the wrong direction this can normally be detected as the unit runs louder and pumps less 5 For three phase motors make sure that the motor i...

Страница 19: ... into the housing See page 65 figure 10 7 1 4 Setting the ball nozzle The direction of the ball nozzle is adjustable The nozzle is normally set in a horizontal or slightly upwards position which then provides the optimal effect for counter swimming Ensure the ball nozzle is fully opened by turning it anti clockwise before start up 7 1 5 Cover damage The cover is not designed to withstand excessive...

Страница 20: ... physician The mas sage hose is not a toy and is not be used by children The model Badu Jet Stella is delivered together with a blind cou pling which is used to attach the massage hose to the second noz zle This allows an optimal underwater massage 7 2 2 Air regulation and the massage hose Ensure the air regulator is closed before a massage otherwise water will be forced through due to the increas...

Страница 21: ...pool manu facturer 8 1 Failures Problem Possible Cau se Possible solution Unit cannot be switched on Positional switch is not snapped into place Check the cover position Overhang counter swim unit is shut off by the built in or external over load switch Overload Check the overhang counter swim unit See chapter 8 1 1 page 56 The pump has seized Mechanical seal has become stuck through lack of use T...

Страница 22: ...nit from the power supply Turn the motor shaft on the fan side with a screwdriver and check that it is running smoothly Motor shaft not running smoothly Remove screwdriver Notify customer services and have the overhang counter swim unit inspected Motor shaft runs smoothly Remove screwdriver Reconnect the power supply If the pump has seized repeated starting can damage the motor Only switch the uni...

Страница 23: ...f the case pf pump leakage the unit may not be operated and must be disconnected from the power supply After finishing maintenance work take all required steps for start up See chapter 6 page 51 9 1 Care Instructions If needed wash the unit with water and wipe with a moist cloth Do not use abrasive cleaning agents A few sprays of a cleaning agent especially for the use on acrylic sur faces can be ...

Страница 24: ... bar 0 90 0 90 1 10 1 00 1 00 Flow velocity 2m from the nozzle m s 1 10 1 10 1 20 1 15 1 40 Massage pressure bar max 1 20 1 20 1 60 1 60 1 60 Number of nozzles Ø 40 mm pieces 1 1 1 1 2 Omni directional swivel nozzle degrees 60 60 60 Control Pneumatics Pneumatics Pneumatics ON OFF switch accessi ble from inside the pool Yes Yes Yes Attachable massage hose Additional Additional Additional Attachable...

Страница 25: ...ADU Jet BADU Jet BADU Jet BADU Jet nach EN 13451 250 811 367 1127 405 438 45 mm 294 min 777 max 1390 nach EN 13451 250 811 367 1127 405 438 45 mm 294 min 777 max 1390 nach EN 13451 45 mm nach EN 13451 45 mm 22 02 2012 TB b mz_bj_perla_riva_stella ai 400 400 fig 1 ...

Страница 26: ...A1 L3 5 L2 3 1 L1 6 T3 4 T2 2 T1 2 1 N N 96 98 97 95 1 2 3 4 E07 Pump Powersupply 400V 3 N AC 50HZ 40 0 03 A Fuse Pump motor M 3 Control box Y Direction of rotation right In pump is operated at 400V 3N AC 50 Hz as delivered In pump is operated at 230V 3N AC 50 Hz Y X1 Δ P 21 22 LED P E P 12V 230V SELV LED 12V 230V SELV 3 rt bl gr LED A1 N L Stand 02 2012 Connected to Q1 A1 and LED pneumatics butto...

Страница 27: ...th leakage switch IΔN 30 mA slow blow fuse 400V 16 A 50Hz FI Main emerceny switch disconnects oll phases 3 N 400V 1 230V Main emerceny switch disconnects oll phases fig 4 10 4 Information on Safety Position Switch Key Safety Switch When replacing the cover make sure the key snaps snugly into the safety switch fig 5 ...

Страница 28: ...766 2330 061 05 2013 10 5 Securing the unit to the ground 13 06 2012 TB b befestigungsbohrungen ai Dimension in mm Diagram for drilling the mounting holes on an inground pool 368 Pool Wall 30 Drill holes Ø 10 mm 286 350 fig 6 ...

Страница 29: ...ig 7 Fig 8 Pos Part Piece Piece Qty Qty Description Article no Ref 25 4 Dowel M8 Brass 2306 006 006 26 4 Rubber metal buffer M8 x 36 mm 2306 006 005 30 4 Washer d 8 4 x 24 mm A2 5879 021 080 31 4 Lock washer d 8 4 mm A2 5876 797 080 32 4 Hexagon bolt M8 x 25 mm A2 5879 330 825 ...

Страница 30: ...pic support foot 9 7 6 5 4 3 10 2 8 7 6 1 fig 9 Pos Part Piece Piece Qty Qty Description Article no Ref 1 4 Elbow 231 9007 001 2 1 Telescopic safety support 2319 851 000 3 4 Hexagon bolt M12x35mm Ks 5869 331 235 4 4 Lock Washer Ø 13mm A2 5876 797 120 5 4 Washer Ø 13mm A2 5871 251 200 ...

Страница 31: ...mm A2 5879 021 080 7 8 Lock Washer Ø 8 4mm A2 5876 797 080 8 4 Nut M8 A4 5879 340 800 9 4 Hexagon bolt M 8 x 50mm A2 5879 330 850 10 4 Dowel M8 Brass 5879 330 816 10 7 Various Drawings Unit ON OFF press Air regulation OPEN CLOSED turn Lights ON OFF press fig 10 ...

Страница 32: ...10 Appendix I 66 EN VG 766 2330 061 05 2013 fig 11 55 fig 12 fig 13 ...

Отзывы: