12
X2
2 SEC
2
ON
STARTUP
DIAGNOSTIC
OFF
MOTOR OK
BATTERY OK
LIGHT OK
REMOTE OK
ANY LED BLINK x2:
• Connection failed
• Component can’t
be found
M
OTO
R
B
A
TTER
Y
LIGHT
R
EMO
TE
If the system is not functioning correctly, apply the steps below. If the system still does not work correctly, please take the bicycle to an Authorized
Specialized Dealer.
Restart system
Restart system
Make sure battery is off
Take bicycle to an Authorized
Specialized Dealer
Take out battery
Install in bicycle
Turn on, wait 5 sec, turn off again
Go ride
Go ride
G. Error codes displayed
The BMS of the battery automatically checks the functionality of the system. If the system detects an error, the corresponding error message is
displayed on the screen.
If you receive such an error, please restart the system. If the error message continues to be shown, please contact your Authorized Specialized Dealer
for further instructions. Depending on the type of error message, the system may be switched off automatically. It is possible to continue riding with
this system switched off without support from the motor, at any time.
Message displayed Meaning
Solution
The battery is too hot
Please pull over and turn off the system. Allow the system to cool down for long enough that
the error message is no longer displayed. It is also possible to continue riding without battery
support, which aids the system’s cooling process
The battery is too cold
Allow the system to warm up at room temperature for long enough that the error
message is no longer displayed
Battery damaged
Please contact your Authorized Specialized Dealer immediately
Battery is in protection mode
Restart the system. If the error continues to be displayed, contact an Authorized
Specialized Dealer
Short-circuit
Please contact your Authorized Specialized Dealer immediately
Battery management is not
communicating with the components
Restart the system. Check the connections
Low battery
Connect the battery to the charger and plug into a power source to charge the battery
Motor overheating
Please pull over and turn off the system. Allow the system to cool down for long enough that
the error message is no longer displayed. It is also possible to continue riding without battery
support, which aids the system’s cooling process. Do not touch the motor! Danger of burns!
Motor very warm; danger of overheating Reduce speed. Only ride in eco mode. Do not touch the motor! Danger of burns!
Motor damaged
Please contact your Authorized Specialized Dealer
Remote damaged
Please contact your Authorized Specialized Dealer
Please only allow an Authorized Specialized Dealer to carry out all checks and repairs. If the error continues to be displayed despite
attempted solutions, contact an Authorized Specialized Dealer.