background image

A

B

C

INSTALL ESCUTCHEON TRIM

4

A.

 Measure from the finished wall to the first thread of the Adapter. Cut the Cover Tube to this length.

B.

 Slide Escutcheon over the supply pipe until it is against the wall.

C.

 Slide Cover Tube over the supply pipe and press into the Escutcheon.

A

B

TOWARDS

VALVE INLET

INSTALL CONTROL STOP

A.

 Apply Thread Sealant Tape to the Threaded Pipe Adapter. 

B.

 Thread the Control Stop onto the Threaded Pipe Adapter. Using a Strap Wrench, tighten into the 

final position. Outlet should point towards the Valve Inlet and be parallel to the floor.

5

A

B

REMOVE CONTROL STOP COVER

A.

 Loosen, but do not remove, the Set Screw of the Control Stop Cover using the included 2.5mm 

Hex Key. 

B.

 Remove Control Stop Cover.

6

D

C

C

A

B

FLUSH SUPPLY LINE AND INSPECT FOR LEAKS

A.

 Using a Flat Tip Screwdriver, verify that the Control Stop Valve is fully closed by turning 

Adjustment Screw clockwise until fully seated.

B.

 Slowly turn ON water supplies and inspect for leaks and piping issues.

C.

 Hold a bucket or catch basin at the outlet of the Control Stop. Slowly open the Control Stop 

Adjustment Screw by turning a Flat Tip Screwdriver counter-clockwise and flush out any debris.

D.

 Return the Adjustment Screw to a fully closed position.

7

B

A

VERIFY VACUUM BREAKER INSTALLATION

A.

 Verify that the Split Ring and Vacuum Breaker are properly installed within the Tailpiece.

B.

 Slide the Coupling Nut onto the Tailpiece as shown below.

8

Spud Nut

Fiber Washer
Rubber Gasket

Escutcheon

C

B

A

Coupling Nut

D

NOTE: Dry connections only! Do NOT use any thread sealant!

TAILPIECE INSTALLATION

A. Verify the Coupling Nut is installed as per the previous step. 
B. Slide the Spud Nut, Fiber Washer, Rubber Gasket, and Escutcheon onto the Tailpiece in the 

order specified. 

C.

 Install the Tailpiece Assembly into the fixture’s Spud.

D.

 Hand tighten the Spud Nut to the fixture’s Spud. You can use a Strap Wrench, but do NOT fully 

tighten.

9

Содержание SV-4012

Страница 1: ...er Repair kits are available for purchase for each of the components given above as well as components that will need to be serviced less frequently such as the spud nut assembly and inlet piping assembly See Repair Parts section of this document for a full list of repair kits that are offered for this product NOTE Regulations prohibit using replacement parts for this product that would increase t...

Страница 2: ...osed by turning Adjustment Screw clockwise until fully seated B Slowly turn ON water supplies and inspect for leaks and piping issues C Hold a bucket or catch basin at the outlet of the Control Stop Slowly open the Control Stop Adjustment Screw by turning a Flat Tip Screwdriver counter clockwise and flush out any debris D Return the Adjustment Screw to a fully closed position 7 B A VERIFY VACUUM B...

Страница 3: ...e Assembly B Tighten the connection between the Valve Body and Control Stop C Tighten the connection between the Tailpiece Assembly and Spud Nut 12 C A B E D ACCESS BATTERY BOX A From behind the Valve Body loosen but do not remove the Set Screw with the included 2 5mm Hex Key Wrench B Lift off the Valve Body Cover C Disconnect the BLACK wire connection to the Solenoid D Remove the Battery Box from...

Страница 4: ...cally balanced this is normal 17 REINSTALL CONTROL STOP COVER Reinstall the Control Stop Cover using the included 2 5mm Hex Key Wrench 18 CALIFORNIA PROPOSITION 65 CALIFORNIA PROPOSITION 65 WARNING This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ...

Страница 5: ...147 TAILPIECE NUT RPG05 118142 VACUUM BREAKER KIT RPG05 118161 AA BATTERY BOX RPG11 118155 MANUAL OVERRIDE KIT RPG11 118156 MANUAL OVERRIDE INTERNAL KIT RPG11 118157 MANUAL OVERRIDE GASKET AND SEAL KIT RPG11 118158 MANUAL OVERRIDE COVER KIT RPG20 118133 SENSOR AND VALVE COVER KIT SV 4012 RPG20 118135 SENSOR AND VALVE COVER KIT SV 4016 RPG31 118140 TAILPIECE PIPING SV 4012 4016 4116 4128 RPG31 1181...

Страница 6: ...e per Second a The batteries have been used up The batteries must be replaced 4 The Flush Valve is Flushing Continuously or Does Not Shut Off a Check for an audible click from the solenoid i If there is an audible click proceed with troubleshooting step 4 b ii If there is no audible click order a replacement solenoid b The bypass in the valve body is likely clogged with debris or build up from the...

Отзывы: