18
www.SpeakerCraft.com
CONFIGURING YOUR SYSTEM
Windows Vista 8
1. Select Windows Control Panel > Network and Internet > Network Connections
2. Right click Ethernet and select Properties.
3. Highlight Internet Protocol Version 4 (TCP/IPv4) in the connections list and then select Properties.
4. Set a unique IP address compatible with the factory default IP address
http://192.168.1.100 (e.g 192.168.1.220)
5. Set Subnet to 255.255.255.0
LOCAL AREA NETWORK CONNECTION
The network IP address of the SC16-50 (both the factory default address and
any address set manually using the Configuration and Setup Tool) is static and
must be a unique IP address compatible with the LAN it is connecting to.
Use the following steps to establish network communication between a PC,
iPad, smartphone or Tablet and the SC16-50 when using a LAN connection.
1. Use a Windows PC and a Direct Ethernet Connection, as described above,
to initially establish communication with the SC16-50.
2. Use the Network Settings Main Selection instructions located on the
next page of this manual to set an IP address compatible with the LAN.
3. Connect the RJ-45 network connector on the rear panel of SC16-50
to the LAN router or Ethernet Switch.
Note:
iPads, smartphones and most tablets will connect to the LAN via Wi-Fi.
If you plan on connecting multiple SC16-50’s to a network, connect them one
at a time changing each amplifier’s IP address to a unique address compatible
with your network.
Warning:
Never allow two or more SC16-50’s to connect to the same network
with the same IP address.
Note:
If necessary, the MAC ID is located on the bottom rear of the unit.