![Spartus 45PFC Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/spartus/45pfc/45pfc_user-manual_1340299011.webp)
USER’S MANUAL
EN
9
harmonized standards:
EN 60974-1
Arc Welding Equipment
– Part 1: Welding Power Sources
EN 60974-10
Arc Welding Equipment
– Part 10: Electromagnetic Compatibility
Requirements
4.1 CE MARKING
CE
marking is placed on the nameplate of device and/or on the front panel of device.
4.2 RATING PLATE
Rating plate and serial number are located on the bottom of the device case.
5. GENERAL DESCRIPTION
SPARTUS® ProCUT 45PFC
It is an inverter plasma cutter with integrated CNC control socket. Designed for cutting metals
and other electrically conductive materials. It is powered with one-phase 230V source power.
Through the use of modern technology, we have obtained excellent source with maximum
cutting current 40A. The maximum thickness of cut material is 25mm.
Built-in system of contactless pilot arc ignition without HF – provides excellent quality of cutting
edge and longer life of consumables.
The easy-to-use panel with an LCD display allows for smooth adjustment of the cutting current
and setting the appropriate pressure. In addition, the cutter is equipped with a 2T / 4T mode
selector switch.
SPARTUS® ProCUT 45PFC is professional plasma cutter that will find application in manufacturing
sectors, industry and as source of CNC plasma tables.
5.1 PURPOSE OF USE
SPARTUS® ProCUT 45PFC plasma cutters is designed for thermal cutting
(plasma cutting)
steels
and any other nonferrous metal and other electrically conductive materials.
6. TECHNICAL SPECIFICATIONS
6.1 OPERATION, STORAGE AND TRANSPORT
Conditions during operation, storage and transport
Range of ambient air temperature
during operation
-10°C to +40°C
Relative humidity of the air
up to 50% at +40°C
up to 90% at +20°C
Ambient air
free from abnormal amounts of dust, acids,
corrosive substances etc. other than those
generated by the welding process
Base of the welding power source inclined
no more than 10°
Range of ambient air temperature
during storage and transport
-20°C to +55°C