GB
25
11. TECHNICAL DATA
General data
Nominal heat output kW (closed operation)
Thermal output range kW
Efficiency %
Required chimney diameter (mm)
Flue gas connection: Ø mm
Possible flue gas connection Ø mm
Weight (approx.) kg
Required minimum cross-section for supply and recirculating air (with WLM) cm
2
Required minimum cross-section for recirculating and supply air (without WLM) cm
2
Testing and values
non-self-closing combustion chamber door (Design A)
self-closing combustion chamber door (Design A1)
Operation with open combustion chamber door
Level 2 BlmSchV [Ordinance in the Implementation of the Federal Immission Control Act]
15a BVG
Operation with open
combustion chamber
(multiple allocation
not
permitted)
Mass flow of flue gas g/s
Flue gas temperature °C
Flue gas temperature behind the NSHF °C
Combustion air requirement m
3
/h
Required supply pressure: in Pa
Operation with
closed combustion
chamber (multiple
allocation permitted)
Mass flow of flue gas g/s
Flue gas temperature °C (on the flue gas outlet)
Required supply pressure: in Pa
CO
2
%
Required diameter after M-FeuVo. cm
Combustion air requirement m
3
/h
Heating chamber
distance
to the heating chamber wall cm
To the setup floor cm
Heat insulation
(example rock wool
matting to AGI-Q
132)
Setup floor cm
Mounting wall cm
Side wall cm
Stud wall with a wall that must be protected cm
Substitute insulation
material, calcium
silicate
Setup floor cm
Mounting wall cm
Side wall cm
Heat distribution
Convection %
Viewing panel %
H
2
O %
Mini
R1V51
Mini
R1V 57
Mini
R1V 51
NSHF
Mini
R1V 57
NSHF
Mini
R1Vh 57
Mini
R1Vh 57
NSHF
Mini
Z1
Mini
Z1 NSHF
5.2
5.0
6.2
6.2
5.0
6.2
7.0
10.0
4.5-6,8
4.5-6,5
4.5-8,1
4.5-8,1
4.5-6,5
4.5-8,1
4.9-9,1
7.0-13,0
80
> 80
> 80
> 80
> 80
> 80
>78
>80
160
160
160
160
160
160
180
180
160
160
160
160
160
160
180
180
-
-
-
-
-
-
-
-
125
126
125
126
150
150
160
160
700
700
700
700
700
700
700
-
650/780
650/780
930/970
650/780
650/780
650/780
950/1140
1360/1640
-
-
-
-
-
-
-
-
-
-
-
-
-
-
20.9
-
-
-
-
-
-
-
240
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
68.7
-
-
-
-
-
-
-
12
-
4.7
4.0
6.0
5.0
4.0
5.0
7.5
7.6
255
258
355
(164 behind NSHF)
355
(193 behind NSHF)
258
355
(193 behind NSHF)
330
470
(240 behind NSHF)
12
12
12
12
12
12
14
14
9.8
11.3
8.0
10.0
11.3
10.0
8.6
11.1
15
15
15
15
15
15
15
15
16.2
13.4
21.4
17.2
13.4
17.2
25.5
25.2
9
9
11
11
9
11
10
10
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
12
12
12
12
12
8
8
12
12
12
12
12
12
8
8
10
10
10
10
10
10
10
10
0
0
0
0
0
0
0
0
9
9
9
9
9
9
6
6
9
9
9
9
9
9
6
6
62
60
62
60
60
60
68
74
38
40
38
40
40
40
32
26
0
0
0
0
0
0
0
0
Changes and mistakes reserved
* Fulfils 15a 2015 only with AT hand piece, attention: flue gas conn 160 mm
*** Values were not available at the time of printing.
*** Deviating insulation guidelines apply for GET fireplace inserts. This can be obtained from the separate GET manual.
GB
Содержание Mini R1V 51
Страница 1: ...Installation instructions Fireplace inserts ...
Страница 40: ...GB 40 NOTES NOTES ...