Spartherm Australia Freestander Скачать руководство пользователя страница 21

21

630564_1

Elevating mechanisms, operation 

devices such as handles, adjustment 

leavers, shock absorbers, electronic 

and electrical components such as 

exhausters, governors, and safety 

devices

2 Years*

Fireclay bricks / vermiculite, fire 

grates, seals and glass**

6 months*

* From date of purchase 

** Fireclay Bricks / vermiculite: These are natural products subjected to 

expansion and contraction during the heating process. This may create 

cracks. For as long as the linings remain in position in the fire chamber 

and do not break up, they remain fully functional and hence not subject to 

warranty claims.

1.2  Escea must pre-authorise all warranty work.

1.3  The benefits provided by under this warranty are in addition to the 

consumer guarantees and any other statutory rights you may have under 

the consumer law and/or other applicable laws.

2.0 Warranty Exclusions

2.1  This warranty does not apply and will be void where:

2.1.1  The Spartherm fire is not installed in accordance with AS/NZS 

2918:2001 and any building code and consent.

2.1.2  The Spartherm fire has not been installed or operated in 

accordance to the Spartherm installation manual, in particular, 

defects, malfunctions or failures caused by incorrect 

installation, normal wear and tear, misuse, neglect, lack of 

proper and regular maintenance, accidental damage any other 

alteration, or failure to follow operating instructions in the 

installation manual or any misuse that causes an overfired 

situation resulting in heat damage. 

2.1.3  The use of products, including flue systems that are not 

specified in accordance with installation manual.

2.1.4  Installation of the fireplace, repairs or modifications by persons 

not authorised by Escea, use of parts not supplied by Escea, or 

damage or other events which have occurred since the product 

left the control of Escea.

2.1.5  Any scratches, dints, finger print marks and melted items that 

occurred after the arrival of the product to the Spartherm 

Dealer.

2.1.6  Discolouration of the enamel, galvanized surfaces or glass 

caused by soiling by soot or built-in residues of burnt materials 

as well as visibly changed colour or other aspects due to 

thermal stress, or overload.

2.1.7  If the installation and operating instructions are not followed 

resulting in the overheating of the pulleys and bearings.

2.1.8  Improper handling of fragile components such as glass.

2.1.9  Damage caused by incorrect use or the burning of treated 

or painted wood, driftwood or other fuels which are not 

recommended.

2.1.10  Changes in the interior / exterior surfaces of the house, fire 

or flue (e.g. any staining or soot / smoke damage, cracking, 

discoloration or degradation of surfaces caused by thermal 

stress).

2.1.11  Damage caused by abnormally corrosive environments (e.g. sea 

salt corrosion).

2.1.12  Damage caused by water affecting the Spartherm fire. 

2.1.13  Operation of the Spartherm fire without its fire clay bricks, 

vermiculite, door seals, fire grates, complete glass doors in 

place or partly open doors will create an overfired situation 

resulting in damage, which will not be covered by warranty.

2.1.14  Spartherm wood fires are coated with high temperature paint 

that may show signs of surface rust if exposed to moisture for 

an extended period of time. Escea reserve the right to prep and 

paint a brand new fire that has just been delivered rather than 

supplying a new fire in the rare event any rust is present. Any 

subsequent rust damage is not covered by warranty.

2.1.15  This warranty does not cover paint blemishes or imperfections 

because of the uneven nature of high temperature paint. A 

spray can of touch up Spartherm paint is available and can be 

purchased from your Spartherm dealer.

2.1.16  Subject to any statutory provisions to the contrary, at Escea’s 

discretion, Escea’s liability in respect of Spartherm products 

Содержание Australia Freestander

Страница 1: ...Instruction Manual New Zealand Freestander ES1 P7S Australia Freestander ES1 P7H...

Страница 2: ...ing for Hardwood 9 4 5 Installing the Fan Assembly 10 4 0 Bricks Baffles Installation 11 5 0 Operation 12 5 1 Fuel 15 5 2 Smoking 15 5 3 Ash Removal Procedures 16 5 4 Creosote Formation Removal 16 5 5...

Страница 3: ...CCORDANCE WITH THESE INSTRUCTIONS The appliance should be allowed to cool before servicing Do not operate without fully assembling all components Risk of cuts and abrasions Wear protective gloves and...

Страница 4: ...om e g by means of an exhaust fan or similar mechanical blower as this could affect the combustion of the fireplace or increase the possibility of smoke spillage This appliance is designed to burn nat...

Страница 5: ...DUCT DIMENSIONS 2 1 NEW ZEALAND AUSTRALIA FREESTANDER 486 295 411 95 50 142 15 1145 90 407 10 486 464 13 237 03 243 39 54 497 92 1145 90 1135 90 1122 497 92 464 13 411 60 237 03 Isometric Top View Fro...

Страница 6: ...eter mm Average Emission Factor g Kg Unit Weight Kg New Zealand ES1 P7S Freestander Softwood 7 02 kW 8 23 kW 66 98 150mm 0 79 g Kg 120Kg Australia ES1 P7H Freestander Hardwood 7 32 kW 8 48 kW 67 59 15...

Страница 7: ...nd burn the appliance with the air control if applicable fully open for an hour as the appliance goes through a process of eliminating moisture in the steel and firebricks The initial heat output will...

Страница 8: ...orming to the size requirements in the following table must be installed unless the floor is made entirely from a non combustible material Refer to the following table and diagrams for minimum clearan...

Страница 9: ...eld must be used around the flue Flue 600mm 10mm 35mm 240mm 1035mm Fireplace Flue Shield Ceiling Plate A 0 5mm thick stainless steel ceiling plate must be used spaced at least 11mm from the ceiling 34...

Страница 10: ...G THE FAN ASSEMBLY There are two components to the fan assembly that need to be installed into the fire prior to use 1 Remove the top panel shaded grey below 2 Remove the back panel by loosening not r...

Страница 11: ...ANCE WITHOUT THE FIREBRICKS CHAMOTTE OR BAFFLES IN PLACE CAN RESULT IN EXCESSIVE TEMPERATURES THAT COULD DAMAGE THE APPLIANCE CHIMNEY AND THE SURROUNDING ENCLOSURE DO NOT OPERATE THE APPLIANCE WITHOUT...

Страница 12: ...BURNS REMOVE OPERATIONAL TOOL AFTER USE BRIEF CONTACT MAY CAUSE SKIN BURNS Your Spartherm product is designed with the most advanced technology The appliance is extremely airtight The first fire s in...

Страница 13: ...e smoke from the chimney There will be a bed of orange embers in the firebox and secondary flames flickering just below the top firebrick You can safely fill the firebox with wood up to 50 Once the me...

Страница 14: ...air inlet nozzles at the backside of the firebox or if not present up to 50 of the fireboxes backside height or marked line C Vigorously burning large loads of wood with the draft control on HIGH full...

Страница 15: ...hen loading the appliance ensure to keep fuel back from the glass If fuel is allowed to accumulate on the front lip there is a chance it will fall out when the door is opened Burn only dry clean unpai...

Страница 16: ...The creosote vapors condense in the relatively cooler chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot...

Страница 17: ...ally designed for chimney cleaning The chimney connector and dampers as well as the chimney should be cleaned The appliance s firebox and baffle system should be cleaned if needed The chimney should b...

Страница 18: ...reafter clean as required The glass is very strong but do not let burning fuel rest or fall against it and always close the door gently NEVER FORCE IT SHUT If the glass should ever crack or break whil...

Страница 19: ...lem Solution Can t get the fire started Not enough kindling paper Add more Not enough air Ensure air control is fully open Also ensure that the air opening is not obstructed Cold air blockage Burn a p...

Страница 20: ...s amended Manufactured in Germany by Spartherm GmbH Maschweg 38 D 49324 Melle Distributed in New Zealand by Escea Ltd 17 Carnforth Street Dunedin 9058 Ph 0800 173 000 WARRANTY CONDITIONS FOR SPARTHERM...

Страница 21: ...ol of Escea 2 1 5 Any scratches dints finger print marks and melted items that occurred after the arrival of the product to the Spartherm Dealer 2 1 6 Discolouration of the enamel galvanized surfaces...

Страница 22: ...if a repairer will be required to travel more than 30 km from the nearest service centre to your location You can obtain details on the location of service centres and service call fees by visiting t...

Страница 23: ...1 9 0 SERVICE HISTORY DATA PLATE 9 1 SERVICE HISTORY The appliance must be serviced at least annually and possibly more frequently dependant on usage Date Dealer Name Service Technician Service Perfor...

Страница 24: ...24 630564_1...