Recapture Guide
Auto Antifreeze
Version
RECAPTURE START POSITION
Forward Valves
• Liquid Valve: Open
Rear Valves
• HP Reel Valve: Open
• Fill Reel Shutoff Valve: Open
• HP Water Rocker: Off
Auto Antifreeze Box
• Rotary Switch: Capture
• Tank Drain: Off
1. Verify valves are in start position and that the water tank is at least a quarter full.
2. Verify HP hose is still attached into recirculation panel.
3. Turn key to the run position, do not start engine.
4. Press the cycle start button on the auto antifreeze box to start the recapture process.
5. The unit will now change the remaining valves and start. After 60 seconds water should flow through the pump / HP
hose / garden hose and the clear hose going to the recirculation panel. The unit will automatically shut down when the
unit is recaptured.
6. You may now resume normal jetting with your Elite Soldier.