background image

Spartan Tool LLC

 

    

|

     

SpartanTool.com

6

Antifreeze Guide

Auto Antifreeze 

Version

ANTIFREEZE START POSITION

Forward Valves

•  Liquid Valve: Open

Rear Valves

•  HP Reel Valve: Open
•  Fill Reel Shutoff Valve: Open
•  HP Water Rocker: Off

Auto Antifreeze Box

•  Rotary Switch: Antifreeze
•  Tank Drain: Off

1.  Verify valves are in start position and that the antifreeze tank is at least half full.

2.  Connect HP hose into recirculation panel and tighten fully.

3.  Turn key to the run position, do not start engine.

4.  Press the cycle start button on the auto antifreeze box to start the antifreezing process.

5.  The unit will now change the remaining valves and start. After 60 seconds antifreeze should flow through the pump / HP 

hose / garden hose and the clear hose going to the recirculation panel. The unit will automatically shut down when the unit 
is antifreezed.

6.  Turn off the unit and drain the water tank fully using the drain on the front curb side.

7.  Open the hydrant fill valve to drain any trapped water.

Содержание Elite Soldier

Страница 1: ...ELITE SOLDIER Valve Quick Reference Guide...

Страница 2: ...Y Forward Valves Liquid Valve Closed Tank Select Valve Either Tank OR DRAIN WATER TANK Forward Valves curbside under frame Drain Valve Open ANTIFREEZE TANK DRAIN via Strainer Forward Valves Liquid Val...

Страница 3: ...into recirculation panel and tighten fully 3 Start unit If water tank is drained you may need to turn on the override rocker 4 After 60 seconds antifreeze should flow through the pump HP hose garden h...

Страница 4: ...hat water tank is at least a quarter full 2 Verify HP hose and garden hose are still attached into recirculation panel 3 Start unit 4 After 60 seconds water should flow through the pump HP hose garden...

Страница 5: ...iquid Valve Closed DRAIN WATER TANK Forward Valves curbside under frame Drain Valve Open DRAIN ANTIFREEZE TANK via Strainer Forward Valves Liquid Valve Open Strainer Cap Off Auto Antifreeze Box Rotary...

Страница 6: ...to recirculation panel and tighten fully 3 Turn key to the run position do not start engine 4 Press the cycle start button on the auto antifreeze box to start the antifreezing process 5 The unit will...

Страница 7: ...s at least a quarter full 2 Verify HP hose is still attached into recirculation panel 3 Turn key to the run position do not start engine 4 Press the cycle start button on the auto antifreeze box to st...

Страница 8: ...OFFICE 1506 West Division Street Mendota IL 61342 FACTORY 1618 Terminal Road Niles MI 49120 800 435 3866 SpartanTool com CONTACT US...

Отзывы: