2. Connect the Burner Assembly
to gas supply using supplied
flex connector and shutoff
valve.
3. Evenly fill the media
compartment with burner
media (broken tempered
glass) fully covering the
burner as shown on a picture.
If you are NOT planning to
add optional topping media,
then
fill
the
media
compartment in full and
proceed to the step 5.
NOTE
: If you are planning to
add some topping media
(optional colored glass or
lava rock), leave appro-
ximately ¾” not filled on top
of burner media and proceed
to the next step.
4. Place and evenly distribute
topping media (optional
colored glass or lava rock) on
top of burner media as shown
on a picture.
Make sure that pilot opening
is not blocked with excess of
media.
5. Carefully leak test all
connections following the
procedure on page 5.
1. Remove Burner Assembly,
Front Cover and Burner
Media from packaging (see
Parts List,
page
14
).
6. Having free access to the
valve
and
manifold
compartment of the Burner
Assembly turn ON the
appliance
following
the
procedure on page
8
.
Make sure the flame is even
along the burner and
appliance is fully operational
and safe for use. Turn OFF
the appliance and let it cool
before proceeding to the next
step.
the parts in accordance with
these diagrams or failure to
use only parts specially
approved with this appliance
may
result
in
property
the
metal
data
plates
Burner System.
important information.
circulating air passageways
clean.
4
PRODUCT ASSEMBLY
INSTALLATION
CAUTION: Do not remove
WARNING: Failure to position
These
plates
contain
attached
to
the
Linear
NOTICE: Installation
and
repair should be done by a
qualified service person. The
appliance
should
be
inspected before use and at
least annually by a qualified
service person. More fre-
quent cleaning may be
required as necessary. It is
imperative
that
control
compartment, burner and
of the appliance be kept
WARNING:
Never light th
e appliance without
having the clear glass media
completely
covering the burner!
damage or personal injury.
- Top……… 60” (153 cm)
-
Short Side of the Unit
to Wall ……. . 9” (23 cm)
- Long Side of the Unit
to Wall …… 16” (41 cm)
No Thermal Floor Protection Required
Fuel pressure specification:
Inlet
Nat. Gas
(NG)
Min:
4.5”
w.c.
Max:
10.5" w.c.
Manifold (NG)
3.5” w.c.
Inlet
Propane
Min:
11.0”
w.c.
Max:
13.0" w.c.
Manifold
10.0” w.c.
7. Cover manifold and valve
compartment of the Burner
Assembly with Front Cover.
Install the Rear Tray on oppo-
site side from the burner.
8. Fill
the
tray
s
with topping
media to
desired level.
CLEARANCES TO
COMBUSTIBLE MATERIALS
FROM BURNER
: