Spark modern fires FT108-N Скачать руководство пользователя страница 10

L100001

35

Continued

APPROVED LEAK TESTING METHOD 

You may check for gas leaks with the following methods only:

• Soap and water solution
• An approved leak testing spray
• Electronic sniffer

NOTE: Remove any excessive pipe compound from 
the connections. Excessive pipe compound can set 
off electronic sniffers. 

"INSTALLATION AND OPERATING INSTRUCTIONS FOR SKYTECH MODEL: 1001 T/LCD-A"".

  OPERATING INSTRUCTIONS

Check for gas leaks in each of the following locations:

• Pipe from the gas supply line connection to the gas valve

Burner connections, pilot

Field made joints / gas shutoff valve

All joints on valve and control body

Factory made joints, each joint and connection

WA

If  using  a  soap  and  water  solution  to  test 
for  leaks,  DO  NOT  spray  solution  onto 

electronic parts

.

WARNING

Never use an open flame to check for gas leak.

DANGER

1.

STOP! Read the safety information on previous page.

2. Turn off all electric power to the appliance.

3. Do not attempt to light the pilot by hand.

If you don't smell gas, go to the next step.

WARNING

7. Turn the gas control manual valve to the ON position.

 

8. Plug supplied 7V DC adapter into 110V power outlet.

 

 

LIGHTING  FOR  THE  FIRST  TIME 

4. Remove Front Tray from the appliance 

(see Illustrated Parts List, page 14).

 

5. Turn the gas control manual valve to the full OFF position.

6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow "B" in the safety information (see page 7).

9. Connect the wire to the DC input plug at the unit.

 

11. Locate Remote Receiver inside of the unit 

(see Illustrated Parts List, page 13).

 Make sure that the slider switch

 

13. Read and follow instructions in how to set up and to use remote control described in supplied

 

14. If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call

 

your service technician or gas supplier.

of the Receiver is in "REMOTE"  (middle) position.

10. Lift and remove Heat Shield covering electronic components inside of the unit 

(see Illustrated Parts List, page 13).

 

12. Replace Heat Shield and then replace Front Tray.

  

10

Содержание FT108-N

Страница 1: ...ou Never use this appliance in an enclosed space as a camper tent car or home DANGER If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from the app...

Страница 2: ...on or near the appliance 6 Clothing or other flammable high surface temperatures and should stay away to avoid burns or clothing ignition trical Code ANSI NFPA 70 or the Canadian Electrical Code CSA...

Страница 3: ...iance is used shall comply with one of the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that inclu...

Страница 4: ...before proceeding to the next step the parts in accordance with these diagrams or failure to use only parts specially approved with this appliance may result in property the metal data plates Burner...

Страница 5: ...lustrated Parts List page 15 must be in place when appliance is not in use Firetable Dimensions Firetable can be installed on any non combustible materials FT36 N P FT48 N P FT60 N P FT72 N P FT84 N P...

Страница 6: ...off the gas to the appliance Check your building codes for any special re quirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male NPT threads This will...

Страница 7: ...er immediately 2 To ease installation a 30 mm flex line with manual shut off valve has been provided with on this appliance Install and attach 1 2 gas line onto shut off valve Outlet Pressure Tap Pilo...

Страница 8: ...TUBE N G Prop MEDIA BURNER TRAY PILOT BURNER TUBE 10 3 4 25 6 7 1 5 OVERAL WIDTH W TOP COVER DIMENSIONS TOP COVER WELD ON HANDLE TOP COVER WIDTH W 0 65 4 1 2 5 17 5 4 16 FT36 N P 24 20 41 000 33 500...

Страница 9: ...D BEFORE OPERATING LIGHTING FOR THE FIRST TIME INITIAL LIGHTING Purge air from the supply line as follows Open main shutoff valve Unscrew main pressure test point Leave inlet test screw open until gas...

Страница 10: ...o light the pilot by hand If you don t smell gas go to the next step WARNING 7 Turn the gas control manual valve to the ON position 8 Plug supplied 7V DC adapter into 110V power outlet LIGHTING FOR TH...

Страница 11: ...lectrical power supply or performing service All wiring shall be in compliance with all local city and state codes The appliance when installed must be electrically grounded in accordance with local c...

Страница 12: ...operation The pilot flame must always be present when the fireplace is in operation or connected to the gas line with main shutoff valve open and the IPS activated powered The pilot flame has two dis...

Страница 13: ...ts to produce moderate levels of carbon soot where flames Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner flame is too low or too...

Страница 14: ...leads disconnected 1 Pilot flame needs adjusting 1 Gas leak See Warning statement above 1 Gas leak See Warning statement above IMPORTANT Operating unit where impurities in air exist may create odors C...

Страница 15: ...FOR PART DESCRIPTION SEE NEXT PAGE 16 ILLUSTRATED PARTS LIST 15 16 18 15 14 1 8 5 2 3 4 6 7 9 10 11 12 13 17 19...

Страница 16: ...120207 W120208 R100027 R100027 R100027 R100027 R100027 3 Pilot Assembly R100028 R100028 R100028 R100028 R100028 1 R100029 R100029 R100029 R100029 D300098 D300098 D300098 D300098 1 5 DFC Wire Assembly...

Страница 17: ...5 1 14 DFC Board H100142 H100142 H100142 H100142 H100142 1 15 Remote Receiver RCB R RCB R RCB R RCB R RCB R RCB R RCB R 1 17 6 Volt Battery Pack H100139 H100139 H100139 H100139 H100139 1 18 7V 10mA DC...

Страница 18: ...17 Pilot Assembly 6 Volt Battery Backup uses 4 pcs AA Batteries...

Страница 19: ...ance Inside Corner Trees Shrubs Other Termination Please Describe Prevalent Wind Conditions Other Installation Notes The installer should complete the form below that describes the details of the inst...

Страница 20: ...and does not extend to 1 firebox burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of r...

Отзывы: