34
L100001
T
TO TURN OFF GAS TO APPLIANCE
Unplug 7V DC adapter from the power outlet.
3.
Turn the gas control manual valve to the full OFF position.
1.
Turn off all electric power to the appliance if service is to be performed.
2.
If necessary, remove Front Tray from the appliance to access manual shutoff valve on gas line.
4.
If necessary, replace Front Tray.
11
ELECTRICAL WIRING
WARNING
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION
Electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city, and state codes. The
appliance, when installed, must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the
National Electrical Code ANSI/ NFPA
70 (latest edition)
and
Canadian Electrical Code, CSA C22.1.
adapter which is required to operate Remote Control. However, during power outage situation, its electronic
system (DFC board) can be temporar
il
y powered with
6
V DC bat
t
ery
pack (4 AA batteries).
This fireplace requires 110V
AC electrical supply for normal operation in order to power up 7V DC
Continued
WARNING
within the appliance.
Do
not operate
the
appliance without the burner being completely filled with glass media.
Lighting the burner without the glass media will cause unsafe temperatures