position.
The maximum current of mA socket is 660mA; over-current will destroy the fuse, and will damage
the meter.
The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage
the operator.
In“ AC ” mode, only can input “AC ”, if not, will damage the meter.
E. Resistance Measuring
b. to select Ω, enter the
Ω
measurement
t
he tester default Auto range status, Press the key manually select
range ,Press “NEAR” to restore “Auto range”
Manual range
:
(Connect the red lead to black leads, will display the
measure range)
000.0Ω
660Ω range
0.000 KΩ
6.600KΩ range
00.00 KΩ
66.00KΩ range
000.0 KΩ
660.0KΩ range
0.000 MΩ
6.600MΩ range
00.00 MΩ
66.00MΩ range
F. Continuity Testing
Page.52.
WARNING!
When measuring in-circuit resistance, be sure the circuit under test has all power removed and
that all capacitors have discharged fully.