Spacetronik SP-IPL07AHD Скачать руководство пользователя страница 28

Press the key  

  or 

 , adjust the focus manually

Press the key  

 or

, manually adjust the zoom

(

2) Color and storage setting 

Click icons “set”

to enter and set analog video image brightness , contrast, color saturation, 

screen snapshot, recording and storage,support Auto-storage and manual storage 

When select manual storage, screen snapshots and recording can be user-defined files name

(3) 10x zoom image display and Video out

when image input

press       to enter “zoom”

press it again to quit.

Zoom in or zoom out image by fingers touch,

 

When image to enlarge,

 

via finger touch screen to the left

, right, up and down move the image,

 

can clearly see every corner of the image.

Page.22.

Содержание SP-IPL07AHD

Страница 1: ...IP camera tester USER MANUAL IPC1 03 SP IPL07AHD SP IPL07SDI ...

Страница 2: ...ead the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will be charged for repair service If there is any question or problem while using the CCTV tester or damages occurred on the product please contact our technical Department ...

Страница 3: ...o testing 6 2 3 9 Cable tester 6 2 3 10 PTZ data analysis 6 2 3 12 Video screenshot record and playback 6 2 3 13 DHCP dynamic address assignment 6 2 3 14 the dynamic address accessed 7 2 3 15 Multi segment IP Camera Test 7 2 3 25 WIFI 8 2 3 26 SDI came test only in SDI model 8 2 3 27 PoE power supply 8 2 3 28 HDMI signal output 9 2 3 29 Network bandwidth testing 9 2 3 30 Cable search Optional 9 ...

Страница 4: ......

Страница 5: ...3 9 Port flash 42 3 3 10 Data monitor 43 3 3 11 Optical power meter Optional 43 3 3 12 Visual Fault Locator optional 45 3 3 13 Digital Multi meter optional 47 3 3 14 Video Player 54 3 3 15 Music player 55 3 3 16 LED lamp Flashlight 56 3 3 17 PoE test 57 3 3 18 TDR cable test optional 57 3 3 19 Calculator 60 3 3 20 Browser 61 3 3 21 IPC viewer 61 3 3 22 DC12V power output PoE power supply 63 3 3 23...

Страница 6: ...ower output 75 3 7 USB 5V 2A power output 76 4 Specifications 77 4 1 General Specifications 77 4 2 Multi meter specifications 79 4 3 Optical power meter specifications 81 4 4 Visual fault locator specifications 82 AHD Model can measure AHD camera s and SDI Model can measure SDI camera s ...

Страница 7: ... the flammable gas Do not disassemble the instrument since no component inside can be repaired by the user If the disassembly is necessary indeed please contact with the technician of our company The instrument should not be used under the environment with strong electromagnetic interference Don t touch the tester with wet hands or waterish things Don t use the detergent to clean and the dry cloth...

Страница 8: ...tenance and installation of IP camera and Analogue camera display HD camera and analogue camera image PTZ control easy to use and operate Built in network testing tools IP address search PING etc quickly check the IP camera problem Cable scan TDR tester easy to check the network cable BNC cable problem Optical power meter Visual fault detector function effective to solve the optical fiber transmis...

Страница 9: ...vel COLOR BURST chroma level measurement test video signal attenuation Optional Cable scan Send the specific signal easy to find the connected cable PING is the most conventional network debugging tools It is used for testing if the connected IP camera or other network equipment s Ethernet port is working normally and the IP address is correct In digital IP surveillance applications if IP camera s...

Страница 10: ...ool file the menu more clearly 2 3 2 IP camera test Built in ONVIF test IP camera tester browser function etc display IP camera image and change IP address 7 inch 800 600 screen display Larger viewing angle it convenient engineers to locate the network camera Built in ONVIF TOOLS and PTZ control IP camera protocols customized support test more than 30 IP camera types now such as ACTi Dahua IPC HFW...

Страница 11: ...r the coaxial cable transmission for the best detail and color Chroma standard level is 280mV in PAL format and is 40 IRE in NTSC format Chroma level is low Chroma level is low the color will become dark color level is too low the details of monitor reception image will be lost and even become black and white chroma level is too high the image will be displayed spot affect the image detail and cla...

Страница 12: ...nd then the connecting status cable type and the sequence of wires will be displayed as well as the serial number of the cable tester kit 2 3 10 PTZ data analysis Search the Control protocol code from Multifunction keyboard or DVR by RS485 RS232 interface test the PTZ control command data whether received anomaly and RS485 RS232 data transmission Screen displays 16 hexadecimal codes such as PELCO ...

Страница 13: ...her network device s IP address 2 3 17 PING Test PING is the most conventional network debugging tools It is used for testing if the connected IP camera or other network equipment s Ethernet port is working normally and the IP address is correct 2 3 18 Port Flashing The tester will send special signals to make the connected POE port flicker at special frequency which will enable the installers to ...

Страница 14: ...handheld instrument specific integrated chip achieve ultra low power operation with the 3 5 TFT LCD High definition screen display five wavelength calibration points 1625nm 1550nm 1490nm 1310nm 1300nm 850nm Linear or nonlinear optical power display it can measure the optical power value and also be used for Relative measurement of optical fiber link loss It is necessary tool for fibre optic commun...

Страница 15: ...C combine with instrument to test Network channel bandwidth 2 3 30 Cable search Optional Send the specific signal easy to find the connected cable 2 3 31 Screen rotation Display Support screen 180 degree rotations manual set the network port will be on the top to convenient connect the cable 2 3 32 AHD camera test only in AHD model AHD video surveillance testing support 720P 1080P digital camera i...

Страница 16: ...10 Audio cable 11 TDR alligator clamp only for TDR models 12 Safety cord 13 Tool bag 14 Manual 15 4G SD card 2 5 Function Page 10 ...

Страница 17: ...n set Confirm the setting of parameters open or enlarge the aperture 11 Return Close Return or cancel while setting parameters of the menu close or decrease the aperture 12 Confirm key 13 Upward set function or add parameter Tilt the PTZ upward 14 Downward set function or reduce the value of the parameter Tilt the PTZ downward 15 Leftward select the parameter whose value will be changed 16 Rightwa...

Страница 18: ...Indicator when charging is red if battery imbue with charge indicator turn off 19 RS485 RS232 Data transmission indicator red color 20 RS485 RS232 Receive data indicator red color 21 external power indicator green 22 Visible red laser source emits Interface Optional Page 12 ...

Страница 19: ...lamp 30 TDR cable test interface 31 HDMI output interface 32 Micro SD card moveable Factory standard card is 4G largest expansion to 16G 33 UTP cable port Please use together with UTP LAN cable tester or wire tracker 34 Audio output and earphone interface 35 Audio input 36 PSE power supply input interface 37 PoE power supply output network test interface 38 USB 5V 2A power output only as a power b...

Страница 20: ...ble of the device when charging show the battery is full or Charge Indicator turns off Indicates that the battery imbue with Notice When the Charge Indicator turns off the battery is approximately 90 charged The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery Notice Press the key several seconds to restore the default settings when t...

Страница 21: ...been powered or network cable s problem Note if IP camera not support external power supply but only support PoE power then connect to tester LAN port to supply PoE Power for IP camera Before connecting the network switch and tester must be disconnecting status It means PSE port cannot be connected to any network cable if supply PoE power When the PoE power turn off PoE switch and PSE can connect ...

Страница 22: ...on the tester 2 CCTV Tester VIDEO OUT interface connect to the Video input of monitor and optical video transmitter and receiver the image display on the tester and monitor 3 Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface Note positive and negative connection of the cable Support RS232 PTZ controller connect the RS232cable to RS232 interface of the tester...

Страница 23: ...ester work abnormally and cannot be turned off Press the key several seconds to turn off the tester reset Select Icons to enter if quit Please click Click SD card mount or unmount SD card Click SD card mount or Unmount SD card Press function Icons seconds tips whether move this icons to APPS files if some function not be often Page 17 ...

Страница 24: ...move that function icons to APPS Click icons APPS tool to show all collected function icons to press key cancel to return menu In APPS files Select icons and press it tips whether move the desktop Files Page 18 ...

Страница 25: ... Recording Photos Video playback PTZ control color and storage setting function Click to quit or press to enter menu Click the screen twice quickly image be displayed on a full screen If tester cannot display image turn on the compatibility mode testing Click the top menu bar Compatibility Mode is turned off to turn on Can shows some require a higher frequency the camera image Page 19 ...

Страница 26: ...as Pelco D Samsung Yaan LiLin CSR600 Panasonic Sony EVI etc B Port Click and move to port Select the communication port for the PTZ camera controlling RS232 485 C Baud Move the yellow cursor to Baud Select the baud rate according to baud rate of the PTZ camera 150 300 600 1200 2400 4800 9600 19200 57600 115200 D Address Set the ID according the ID of PTZ camera 0 254 the setting address data must ...

Страница 27: ...all some special preset number can call the dome camera menu Check and set the protocols address interface and baud must be the same as the dome camera then can test and control After setting the parameter the tester can control the PTZ and lens Fingers touch control Select and click left right upward and downward to control the PTZ direction of rotation by finger touch adjust the zoom PTZ Control...

Страница 28: ...ng and storage support Auto storage and manual storage When select manual storage screen snapshots and recording can be user defined files name 3 10x zoom image display and Video out when image input press to enter zoom press it again to quit Zoom in or zoom out image by fingers touch When image to enlarge via finger touch screen to the left right up and down move the image can clearly see every c...

Страница 29: ... installation position 4 Snapshots and screenshot Click the icons Snapshots when the video in to snapshot and save the current video frame in the SD card as JPEG file if select manual storage appears dialog box Pls input the files name user defined the files name by Chinese character letter or Number form to save in SD card if select Auto storage the instrument auto storage the files after screen ...

Страница 30: ...nese character letter or Number form to storage in SD card if select Auto recording the instrument auto recording the files after screenshots 6 Photos Click the icons photos to enter click the thumbnail pictures to select double click on the screen the image display on a full screen double click again to return Press the screen several seconds rename or delete the files Page 24 ...

Страница 31: ...eo monitor status 7 Record playback Click icons playback to enter Double click to play Click on the top right icons to close and return In the video Playback interface Press the screen several seconds rename or delete the files Page 25 ...

Страница 32: ...igh frequency sampling and processing technology test the Peak video signal SYNC signal level COLOR BURST chroma level more accurate when receive video signal to Auto test measure results display the bottom left corner of the screen While in PAL format the unit will be mV While in NTSC format it will be IRE Page 26 ...

Страница 33: ...ma level is low the color will become dark color level is too low the details of monitor reception image will be lost and even become black and white chroma level is too high the image will be displayed spot affect the image detail and clarity Coaxial cable is too long will reduce the chroma level Image loop test Test video optical transmitter and receiver and video cable Connect one end to the te...

Страница 34: ... image red green blue white and black color Double click display and output on the full screen clickto return menu Application A When maintain the dome camera sending image by it if the monitoring centre received it means Video transmission channel normal it also can judge the image quality via the received color bar B Send the pure color bar such as white and black color to test the monitor wheth...

Страница 35: ...r higher resolution the image display may be delayed while in HD mode the camera stream is H 264 the image display resolution max up to 1080P Click icons to enter ONVIF the icons ONVIF is mode the icons HD ONVIF is HD mode Click icons to enter Auto Scan the same network segment ONVIF camera and list the camera name and address at left screen Some cameras not need user name and password to login Pl...

Страница 36: ...mera click bottom left add users can add camera manually URL address should be the ONVIF camera service address Click the button refresh tester will scan the ONVIF camera again Click the button device list show the IP camera relative information and setting Page 30 ...

Страница 37: ... IP camera s authorization Video live click Video live to enter show the IP camera image Double click showing area image be show on a full screen Double click again to return zoom in image by finger touch Click screen to move it check image each corner details PTZ control click the image to slip left right up down or zoom in or zoom out IP dome camera rotate correspondingly PTZ direction of rotati...

Страница 38: ... down to view the image details while zoom in image status if not via touch can operate by the keyboard press the key to zoon in press the key to zoom out press upward and downward key to move image If IP camera s video image input it support resolution 1080p the clearer image to help engineer Page 32 ...

Страница 39: ...ideo Streaming Click Video Set to enter set the IP camera decoding resolution click OK to save Image setting Click Image setting adjust brightness saturation and contrast Network setting Click network setting to change the IP address Some cameras cannot support Page 33 ...

Страница 40: ... Click Video menu appears camera record photos screen snapshots record playback and storage setting Camera Click snapshot to screen shots and storage if select manual recording appears dialog box Please input the files name user defined the files Page 34 ...

Страница 41: ...rt to count if click the icons again stop recording and save in the SD card if select manual recording appears dialog box Pls input the files name user defined the files name by Chinese character letter or Number form to save in SD card if select Auto recording will auto recording the files after screenshots Set Click icons Set Photo and record function can select if Auto name Photos and recording...

Страница 42: ...ayback Click icons Playback to display video files double click to play click to return Press the video files seconds to delete or rename Video files can play in the Video player of the main menu Page 36 ...

Страница 43: ...lution max up to 1080P Click icons to enter IP camera test Display high definition images photographs video and playback Support Dahua Hikvision Kodak Samsung and such specific camera models testing Customized Note IP camera tester is special design testing tools for IP camera manufacturer it is via customers offer s model to add camera type different series of the same manufacturer IP camera if I...

Страница 44: ...nterface Currently only supported protocol official protocols of DAHUA IPC Camera s address Enter IP camera s IP address click deploy to add IP address of the Different network segments support Multi network segment IP camera test Click search to auto scan the IP camera s IP address and display The tester and IP cameras connect directly and then scanned address is only if not direct connection sca...

Страница 45: ...e function etc Please Ref Video menu of the ONVIF operation 3 3 5 IP address scan Connect the cable to the LAN port click icons to enter set initial IP and ending IP address instrument s IP address network segment and scanned network equipment can be the same network segment or not then click the key Start to scan each and quickly to search the IP address also can input the IP address in the Scan ...

Страница 46: ...ty inconsistencies Error rate 100 if connect well to start Ping test if the test device s IP address is correct sending and receiving packet s quantity consistencies Application PING testing is the most conventional network debugging tools It is used for testing if the connected IP camera or other network equipment s Ethernet port is working normally and the IP address is correct It s normal that ...

Страница 47: ... will be displayed as well as the serial number of the cable tester kit The number of the wire tracker is 255 If need several different number wire trackers should pay the additional cost 3 3 8 Cable scan Connect test cable or BNC cable to the UTP port or the CABLE SCAN VIDEO OUT port on the bottom Click icons to enter click the Number on the screen to adjust audio type Page 41 ...

Страница 48: ...ntenance and network engineering While searching BNC cable connect one port of the alligator clips to the copper core or copper net of the BNC cable the other one to connect the earth wire barred windows Note The battery of the wire tracer must according to corresponding positive pole and negative pole or damage the tester Note While receive the audio signal from the tester it will be influenced b...

Страница 49: ...he LAN port Application The tester will send special signals to make the connected LAN port flicker at special frequency which will enable the installers to easily and quickly find the connected Ethernet cable This function can prevent mistakenly insertion or disconnection non corresponding cable to artificially interrupt network connection Page 43 ...

Страница 50: ...he code on the display The RS485 communication rate must be the same Application Check the RS485 communication states of the video optical transmitter whether normal Engineer can analyze the protocol and check the data through the displayed code 3 3 11 Optical power meter Optional Click icons to enter with five wavelength 1625nm 1550nm 1490nm 1310nm 1300nm 850nm linear or nonlinear optical power d...

Страница 51: ... testing set the wavelength for measurement Click relative difference to test the tester Auto save current fiber power value as the base reference value Input another optical fiber to be measured the displayed new measurement and relative value is red color Press it again to quit Data hold and Relative measuring use together the data is yellow while the function is effect Page 45 ...

Страница 52: ...ur status can select Steady mode Evasive 1Hz Evasive 2Hz and Time off Click button Steady mode to enter steady status click button Evasive 1Hz and Evasive 2Hz to enter pulse mode click button Time off VFL be turned off Timed turn off can select 5mins 10mins Page 46 ...

Страница 53: ... 120mins Click Steady mode red laser sources emit steady click again to quit Click icons Evasive 1Hz or Evasive 2Hz to enter pulse mode the red laser sources emitted by a certain frequency press it again to quit Page 47 ...

Страница 54: ... Measuring AC DC Voltage and current measurement state display Auto range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative measurement Display the relative measurement value Press the key to change display state 10A socket In 10A current measurement state indicate use 10A socket Over range The current measurement value over the range if in the ...

Страница 55: ...0 0V 660 0V range 000 0mV 660 0mV rang B AC Voltage Measuring Page 49 WARNING You can t input the voltage which more than 660V DC it s possible to show higher voltage but it s may destroy the inner circuit Pay attention not to get an electric shock when measuring high voltage WARNING You can t input the voltage which more than 660V AC it s possible to show higher voltage but it s may destroy the i...

Страница 56: ...0mV 660 0mV range C DC Current Measuring only manual range b select A enter the DC current measurement the screen display DC current can select manual range c Manual range 0 000mA 6 6mA range 00 00mA 66 00mA range 000 0mA 660 0mA range 00 00A 10 00A range use 10A socket d Select the range to enter current measurement NOTE When only the figure OL is displayed it indicates over range situation and t...

Страница 57: ...test lead to the mA jack for a maximum of 660mA current For a maximum of 10A move the red lead to the 10A jack b select A enter the AC current measurement manually select the range c Manual range 0 000mA 6 600mA range 00 00mA 66 00mA range 000 0mA 660 0mA range 00 00A 10 00A range use 10A socket Note When only the figure OL is displayed it indicates over range situation and the higher range has to...

Страница 58: ...enter the Ω measurement the tester default Auto range status Press the key manually select range Press NEAR to restore Auto range Manual range Connect the red lead to black leads will display the measure range 000 0Ω 660Ω range 0 000 KΩ 6 600KΩ range 00 00 KΩ 66 00KΩ range 000 0 KΩ 660 0KΩ range 0 000 MΩ 6 600MΩ range 00 00 MΩ 66 00MΩ range F Continuity Testing Page 52 WARNING When measuring in ci...

Страница 59: ...Connect test red lead across to the cathode the black lead to the anode of the diode under testing e Tested diode forward voltage low 30mv there is sound indication then can finish the testing quickly without view the screen H Capacitance Measuring Page 53 WARNING When testing the circuit continuity be sure that the power of the circuit has been shut down and all capacitors have been discharged fu...

Страница 60: ...ss two sides of the capacitor under measurement be sure that the capacitor has been discharged fully Note a The capacitance of a capacitor should be tested separately should not test in the installation of circuit b To avoid electric shock be sure the capacitors have been discharged fully before measuring the ca pacitance of a capacitor c While testing the capacitance of a capacitor to 660uF the M...

Страница 61: ...re than 660V AC it s possible to show higher voltage but it s may destroy the inner circuit Resistance Continuity Diode PTC component Protection Wrong input voltage will Auto enter protection state It only suitable for short and limit time work If input voltage over 600V will damage the meter mA current fuse range 250V 1A if the current over the rated range fuse will melt to protect the meter Pls ...

Страница 62: ...mats MP4 H 264 MPEG4 MKV etc ONVIF tool IPC Test and video monitoring test s video can play directly via video player Video player Auto search the video file on SD card click the files of player list to play directly and click RETURN to quit Click the files several seconds delete or rename the files Page 56 ...

Страница 63: ... 15 Music player Click the icons to enter Only support MP3 format Audio file 3 3 16 LED lamp Flashlight It is convenient for the engineer working in the evening or in the dark Click icons to enter Page 57 ...

Страница 64: ...el or Time setting can select 3 3 17 PoE test Click icons to enter PoE voltage measurement Connect the cable to the power supply equipment s POE port and the tester s PSE IN port Connect IP camera or wireless AP equipment connect tester s LAN port the POE voltage and the cable s connection status show on the screen Note the Poe power supply equipment POE Switch PSE power supply equipment must be P...

Страница 65: ...can t be connected to any equipment or it will damage the tester Connect Alligator clip cable to the TDR port and the cable must connect well before testing or it will influence the accuracy Click to enter and click Start to test Built in BNC network cable RVV control cable Telephone line can test 11 groups user defined cable can be set Click cable type to select cable and start testing click and ...

Страница 66: ...ration 11 groups user defined can be set 1 Select user defined and click Calibration to enter test click user defined 1 can define cable name as AiPu BNC 5 2 Click cable type to select cable when test Please select correspond cable for example if test BNC cable please select BNC etc communication dedicated 75 2 Pls select SYV 75 2 Page 60 ...

Страница 67: ...connected or short circuited reflected pulse generated the tester receive and deal with the reflected wave measurement results displayed on the screen TDR cable test can test cable length and short circuit help engineer quickly find the cable s problem location It is more convenient and efficient to repair the faulty cable Note The TDR reflect signal could be affected by the cable quality cable s ...

Страница 68: ... icons to enter Input the IP camera s IP address click Scan IP to scan browser can be used to log IP camera and change IP camera s address if browser login IP camera successfully the IP camera and instrument must be in the same network Page 62 ...

Страница 69: ...obile phone or tablet client software can install this client software in IP camera tester to view image Click icons IPC viewer to enter run the mobile client software of the corresponding IP camera manufacture then can view the image after setting that client software Mobile client software is to use decompression software to deal with the image Therefore the display image maybe not clearer Note ...

Страница 70: ...Click desktop icons several seconds to uninstall this application Click icons update in the IPC viewer interface to update Mobile client software Page 64 ...

Страница 71: ... input port of the CCTV tester to avoid destroy 3 When the requirement of the camera is higher than 2A the CCTV tester will enter protection mode Disconnect all the connections of the CCTV tester and then connect the CCTV tester with power adaptor to resume the CCTV tester 4 Before turn on the power output Please make sure the IP camera support PoE powered Otherwise damage IP camera 5 Make sure th...

Страница 72: ...ived audio Connect the audio devices to Audio input port click icons to enter and record click the red button to stop and prompt to save the recording Net work test Ethernet bandwidth test Built in Ethernet bandwidth test tools two devices mutual testing one as Server end another as Test Page 66 ...

Страница 73: ... accurate test Please use a professional Ethernet tester Click icons to enter When test need a Instrument or Network Test Software as the Server another one send packet test The two instruments must be in the same network 1 Start the server Click Start the server the tester as a test server end The server IP address Tester s IP address display Page 67 ...

Страница 74: ...e test with an instrument and computer Install network bandwidth testing software on a computer As a test client or server with instrument mutual testing If computer as the server the computer IP address as 192 168 0 89 Instrument as test client instrument IP address is 192 168 0 230 it is the same network segments with Page 68 ...

Страница 75: ... server s IP address in test client 192 168 0 89 click start test to Network bandwidth test Or Instrument as the server computer as test client select client fill instrument IP address to test when instrument tester as server shows results Page 69 ...

Страница 76: ...ign IP address for the IP camera not need set IP camera s static IP address and then start to test Select Start set assigned addresses segment click save start and assign dynamic IP addresses Click refresh to check received IP address Page 70 ...

Страница 77: ...ontents click the key save to save the contents date and time pls click to view the notepad all saving contents display Click each records bar to show the details Press the records bar several seconds prompt whether delete it Page 71 ...

Страница 78: ...k the device s IP address whether be occupied by other device If the status is means the IP address is occupied if the status is means the IP address is available Application Add an IP camera or other network device to the current network group the new IP address must not be occupied otherwise it will cause IP conflicts and stop the equipment normal working Link monitor can check if the new settin...

Страница 79: ... icons APPS to show all icons if click other areas range without icons area to return menu Click icons several seconds prompt whether move the icon to the main menu 3 3 25 System Set 此处有中文图片 Click icons to enter Page 73 ...

Страница 80: ...ther need test IP address as tester s address After setting IP address ref above pictures it can test two network segments IP camera 192 168 0 0and 192 168 1 0 WIFI Turn on Turn off wifi Brightness Set brightness sleep time 15 30 seconds or brightness Volume Set volume SD Card Show SD Card Capacity unmount SD card Power display display the battery level information Version information Check versio...

Страница 81: ...rn off Turn off option Fast turn off When select it the tester running fast and enter main menu Some data is not refreshed and clear to avoid smaller problem please do not use Fast turn off the tester 3 3 26 Update Click to enter If could update it will appear in the update application interface click relative program to update the new version 3 4 Audio test Test the audio input from pickup device...

Страница 82: ... power Support PoE Ethernet power output via RJ 45 port to transmit data also supply DC 48V power output With PoE IP camera power supply can directly connect the camera to tester not need external power Notice a Please make sure the connect cable to Lan port of PoE power output is Straight line otherwise will damage the tester b Before using PoE power output Pls check the IP camera whether support...

Страница 83: ...y output interface it must use tester s power convert cable the smaller end of the cable to connect DC12V 2A OUTPUT the other end connect to camera power input interface Application Power output functions mainly used in the camera field demonstration and testing meanwhile for some camera installation area if there is no power adaptor it can as temporary power to supply power for the camera Notice ...

Страница 84: ...mode Disconnect all the connections of the CCTV tester and then connect the CCTV tester with power adaptor to resume the CCTV tester d Make sure the tester is full charged or more than 3 bars or it will be short circuit 3 8 USB 5V 2A power output USB port of the IPC camera tester support DC5V 2A power output as a power bank When tester be turned off this interface still can output power Provide te...

Страница 85: ...roma level measurement Zoom Image Support Analog camera and IP camera image zoom move Snapshots Video record Record playback Image Screenshots record save view and record play back HDMI output 1 channel HDMI output support 1920 1080P 12V 2A power output Output DC12V 2A power for camera USB 5V power output 5V 2A power output as a mobile phone power bank PoE power output 48V PoE power output Max pow...

Страница 86: ...cable connection status Digital Multi meter optional AC DC Voltage AC DC current Resistance Capacitance Data hold Relative measurement Continuity testing Testing speed 3 times seconds Data range 6600 6600 Optical power meter Optional Calibrated Wavelength nm 850 1300 1310 1490 1550 1625nm Power range dBm 70 10dBm Visual fault locator optional Test fiber s bending and breakage SM and MM fiber TDR c...

Страница 87: ...ith ZERO function Isolation the Multi meter connector must be isolated with the other connector DC voltage Range Accuracy Resolution 660mV Manual range 0 3 4 0 1mV 6 600V 1mV 66 00V 10mV 660 0V 100mV AC voltage Range Accuracy Resolution 660 0mV Manual range 1 5 6 0 1mV 6 600V 0 8 6 1mV 66 00V 10mV 660 0V 100mV DC current Range Accuracy Resolution 6 600mA 0 5 3 1uA Page 81 ...

Страница 88: ...A 10uA 660 0mA 100uA 10 00A 1 5 10mA Resistance Range Accuracy Resolution 660 0Ω 0 8 5 0 1Ω 6 600KΩ 0 8 2 1Ω 66 00KΩ 10Ω 660 0KΩ 100Ω 6 600MΩ 1KΩ 66MΩ 1 2 5 10KΩ Continuity Range Resolution Function 660 0Ω 0 1Ω The measurement value less 30Ω 3Ω the tester will sound Diode Range Resolution Function Page 82 ...

Страница 89: ...5 8 10pF 660 0nF 100pF 6 600μF 1nF 66 00μF 10nF 660 0μF 5 8 100nF 6 600mF 1μF 66 00mF 10μF 4 3 Optical power meter specifications Measure Range dBm 70 10dBm Wavelength nm 850nm 1300nm 1310nm 1490nm 1550nm 1625nm Detector InGaAs Uncertainly 3 dB 10dBm 22 5 dB full range 22 Display Resolution Linear 0 1 Nonlinear 0 01dBm Operating Temperature 10 50 Page 83 ...

Страница 90: ...mW 20mW Modulation mode CW 1Hz 2Hz Measurement Range 5KM optional 10 20KM Connector FC PC exchangeable Working Temperature 10 50 Operating Temperature 20 70 The data above is only for reference and any change of them will not be informed in advance For more detailed technical inquiries please feel free to call the Technical Department of our company Page 84 ...

Отзывы: