Spaceman 6210-50Hz Скачать руководство пользователя страница 7

a.  Coat inside of agitators (if present) with 

Spaceman lubricant and install with arrow 

poin ng up. 

b.  Install internal and front drip trays. 
c.  If machine will be le  unused, install air 

tubes and place hopper lids on top; 

otherwise, set air tubes aside un l a er 

machine has been primed. 

5. I

 

 

 

 

 

IMPORTANT: 

A er sani zing the machine, DO NOT rinse or touch areas that have been sani zed.  

Product must be added immediately. If new product will not be added immediately, rinse machine 

with clean water and loosen door hand-screws to allow cylinders to air-dry. Sani ze machine before 

using again. 

1.  Verify assembly is complete. 
2.  If installed, remove hopper covers and air 

tubes. 

3.  Verify draw valves are in the CLOSED 

posi on (UP). 

4.  Mix a minimum of 8 liters (2.11 gallons) of 

food-grade sani zer in a bucket or 

container. 

5.  Pour half the food-grade sani zer solu on 

into each hopper. 

6.  Turn power switches ON. 
7.  Press RESET bu on; press WASH bu on to 

begin cycle. Allow solu on to agitate for 5 

to 10 minutes; 

NEVER leave machine on 

WASH for more than 10 minutes.

 

8. While 

agita ng, gently use a clean brush to 

scrub and distribute sani zer solu on along 

hopper walls. 

9.  Place a bucket or container below the draw 

valves; OPEN the draw valves (DOWN) and 

drain solu on from the machine. 

10. Press RESET bu ons to stop cycle. 

CAUTION: 

Always use food-grade, no-rinse sani zer to sani ze. If warm water is required to dissolve 

sani zer, allow the solu on  me to cool before adding to machine. 

10 

11

P

 : 

S

 

Before opera ng the machine, it is required that the operator know the func on of each opera ng control.

M  L

 I

˖

A mix level indica ng light is located at the front of the machine. When the light is 

“ON”, it indicates that the mix hopper has a low supply of mix and should be re

fi

lled as soon as possible. 

Always maintain at least 2cm of mix in the hopper. If you neglect to add mix, a freeze-up may occur. This will 

cause eventual damage to the beater assembly, the dispensing door, and gear box. 

D

 S

˖

During normal opera on the display is used to indicate func on, the temperature of the 

mix in the hopper and cylinder, the electric current of beater motor, error, and warning message. 

T

 S

 P

˖

To be er communicate in the Interna onal arena, symbols have replace words on 

many of your operator switches. SPACEMAN equipment is designed with these interna onal symbols. 

1

2

3

4

5

6

Turn on power

Press and hold RESET for 3 seconds to enter into 

Menu;  Press RESET to turn to next page 

M

 D

 I

 

Mix Low Indicator

Touch Switch Panel

Display Screen

Press RESET bu on 

to turn to STOP 

mode

Press WASH bu on 

to turn to WASH 

mode

Press P bu on, 

displays tempera-

ture of Hopper & 

Cylinder

Press STANDBY 

bu on to turn on 

STANDBY mode

Press FREEZE bu on 

to turn on FREEZE 

Mode

Press ICE CREAM 

bu on, screen dis-

plays dispense count

Press P bu on 

again, displays 

motor current 

Viscosity Se ng

Hopper Temperature

Date & Time

12

O

 C

 : 

I

   

1. FREEZE 

B

 

2. WASH 

B

 

3. STANDBY 

B

 

4. RESET 

B

 

5.  ICE CREAM B

 

6. P 

B

 

Содержание 6210-50Hz

Страница 1: ...So Serve Models Two Line Display Standard or Air Pump Counter or Floor Standing SPM D XS TY001 R2 202001...

Страница 2: ...s and accessories Place machine in appropriate food prepara on area Comply with all installa on requirements Read and understand ALL safety and standard opera ng procedures Fully disassemble machine a...

Страница 3: ...n the exhaust side Side or Back units with Airchute installed do not need to meet this clearance requirements x Completely clear area of dust grease and airborne par cles x Place away from hot equipme...

Страница 4: ...the first me For op mal machine performance and many years of e ciency and reliability from your machine Spaceman recommends cleaning and sani zing the machine and its partsweekly 5 R M O M R R M The...

Страница 5: ...osi on 2 Use the large brush and cool water to thoroughly clean inside the cylinder be sure to scrub the back of the cylinder 3 Thoroughly clean and dry the rear of the cylinder with a clean dry towel...

Страница 6: ...H ring on middle draw valve place O rings on prime plugs coat all ring areas with Spaceman lubricant b Push prime plugs into holes on top of dispensing door c Insert draw valves into dispensing door O...

Страница 7: ...m water is required to dissolve sani zer allow the solu on me to cool before adding to machine 8 1 2 2 6 7 10 c 11 P S Before opera ng the machine it is required that the operator know the func on of...

Страница 8: ...sconnec ng air pump first press RESET to stop opera ons and open draw handles for 10 to 15 seconds to relieve pressure in cylinder Side draw handles dispense product from their respec ve hoppers The m...

Страница 9: ...duct level top of hopper agitator blade in hoppers 3 Press RESET press STANDBY Store opening 1 Open draw handles to draw 170 g to 227 g 6 oz to 8 oz of product discard product 2 Press RESET press FREE...

Страница 10: ...installed drive sha seal Remedy 1 Use su cient food grade lubricant and add su cient lubricant inside drive sha gasket during assembly Page 9 2 Replace drive sha gaskets every 1 to 3 months Probable C...

Страница 11: ...1 006 O Ring 16 8x2 4 13 3 4 08 01 002 O Ring 18x2 2 4 3 4 08 02 007 Door Gasket SS 1 3 1 8qt 14 3 4 08 01 041 O Ring 71 8x3 5 3 4 08 02 008 Door Gasket SS 3 4qt 15 3 4 08 01 025 O Ring 15 8x2 4 6 3 4...

Страница 12: ...5 3 5A 6368 50Hz W Inverter 2 3 5A 6260AD 60Hz 2 4 A 6268 50Hz 2 5 3 5A 6268 50Hz W Inverter 2 3 5A 6265 60Hz 2 3 5 A 6338 50Hz 2 5 3 5A 6338 50Hz W Inverter 2 3 5A 6268 60Hz 2 3 5 A 6378 3Ph 380V 50...

Отзывы: