Space Pak SIS Series Скачать руководство пользователя страница 42

– 42 –

Split Inverter Air-to-Water Heat Pump

SpacePak “Solstice Inverter”* Series Air to Water Heat Pumps

Subject to the terms and conditions of this Limited Warranty Statement (the “Limited Warranty”), SpacePak warrants to the original purchaser of the “Solstice Inverter” Series (as used herein, 

“System” shall mean the Solstice Inverter outdoor and indoor components connected via refrigerant piping and electrical wiring purchased on or after February 1, 2021 from a licensed 

HVAC contractor, installed by such contractor in accordance to local and National regulations in the continental U.S., Alaska, Hawaii, and Canada and registered on SpacePak’s website 

located at www.SpacePak.com/warranty that:

1) 

The parts are warranted for a period of two (2) years to the original owner of the system. If any parts should prove defective due to improper workmanship and/or material for a 

period of two (2) years from the date of installation, SpacePak will replace any defective part without charge for that part. Replacement parts are warranted for the remainder 

of the original 2-year warranty period. Parts used as replacement may be of like kind and quality and may be new or remanufactured. Defective parts must be available for 

SpacePak in exchange for the replacement parts and become the property of SpacePak. 

2) 

The compressor is warranted for a period of five (5) years to the original owner of the system. If the compressor should prove defective due to improper workmanship and/or 

material for a period of five (5) years from the date of installation, SpacePak will replace the defective compressor without charge for the compressor. Replacement compressors 

are warranted for the remainder of the original 5-year warranty period. Compressors used for replacement may be of like kind and quality and may be new or remanufactured. 

Defective compressors must be made available to SpacePak in exchange for the replacement compressor and become the property of SpacePak.

3) 

Notwithstanding the foregoing, if the System is installed in a residential single-family home by a SPACEPAK CERTIFIED CONTRACTOR the parts will be 

warranted for five (5) years and compressor will be warranted for a period of ten (10) years, to the original owner, so long as the original owner resides in the home. 

Specifically, if any parts and/or the compressor should prove defective due to improper workmanship and/or material for the period listed above from the date of installation, 

SpacePak will replace any defective parts or compressor without charge for the part or compressor. The replacement parts and/or compressor are warranted for the remainder 

of the original warranty period. Parts and/or compressors used for replacement may be of like kind and quality and may be new or remanufactured. Defective parts and/or 

compressors must be made available to SpacePak in exchange for the replacement parts and become the property of SpacePak.

*For any Solstice equipment that is non-inverter, please refer to warranty located in the equipment original installation manual.

SpacePak Small Duct High Velocity Air Handlers and Hydronic Fan Coils

Subject to the terms and conditions of this Limited Warranty Statement (the “Limited Warranty”), SpacePak warrants to the original purchaser of the Small Duct High Velocity Air Handlers 

and hydronic fan coils (as used herein, “System” shall mean the air handlers or fan coils) purchased on or after February 1, 2021 from a licensed HVAC contractor and installed by such 

contractor in accordance to local and National regulations in the continental U.S., Alaska, Hawaii, and Canada and registered on SpacePak’s website located at www.SpacePak.com/

warranty that:

1) 

The parts are warranted for a period of one (1) year to the original owner of the system. If any parts should prove defective due to improper workmanship and/or material for a 

period of one (1) year from the date of installation, SpacePak will replace any defective part without charge for that part. Replacement parts are warranted for the remainder 

of the original 1-year warranty period. Parts used as replacement may be of like kind and quality and may be new or remanufactured. Defective parts must be available for 

SpacePak in exchange for the replacement parts and become the property of SpacePak.

2) 

Notwithstanding the foregoing, if the System is installed in a residential single-family home by a SPACEPAK CERTIFIED CONTRACTOR the parts will be warranted for five (5) 

years, to the original owner, so long as the original owner resides in the home. Specifically, if any parts should prove defective due to improper workmanship and/or material for 

the period listed above from the date of installation, SpacePak will replace any defective parts or compressor without charge for the part or compressor. The replacement parts 

are warranted for the remainder of the original warranty period. Parts used for replacement may be of like kind and quality and may be new or remanufactured. Defective parts 

must be made available to SpacePak in exchange for the replacement parts and become the property of SpacePak.

SpacePak Buffer Tanks

 

The “Manufacturer” warrants to the original owner at the original installation site that the Hydronic Buffer Tanks (the “Product”) will be free from defects in material or workmanship 

for a period not to exceed ten (10) years from the startup, provided the product is installed in accordance with the manufacturers installation instructions. If upon examination by 

the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of 

the Product which is shown to be defective.

Items 4-6 apply to ALL SpacePak products

4) 

NO LABOR. These limited warranties do NOT include labor or any other costs incurred for service, maintenance, repair, removing, replacing, installing, complying with local 

building and electric codes, shipping or handling, or replacement of the System/Products, compressors or any other parts. For items that are designed to be maintained or 

replaced by the original owner, the original owner is solely responsible for all labor and other costs of maintaining, installing, replacing, disconnecting or dismantling the System/

Products and parts in connection with owner-required maintenance. Please consult the applicable technical documentation for regularly suggested maintenance procedures.

5) 

PROPER INSTALLATION. This Limited Warranty applies only to Systems/Products that are installed by contractors who are licensed for HVAC installation under applicable 

local and state law, and who install the Systems/Products in accordance with (i) all applicable building codes and permits: (ii) SpacePak’s installation and operation instructions: 

and (iii) good trade practices.

6) 

BEFORE REQUESTING SERVICE, please review the applicable technical documentation to insure proper installation and correct customer control adjustment for the System/

Products. If the problem persists, please arrange for warranty service.

a.  

TO OBTAIN WARRANTY SERVICE:

i. 

Contact the licensed contractor who installed the System/Products or the nearest licensed contractor, dealer, or distributor (whose name and address may be 

obtained on our website at www.SpacePak.com of any defect within the applicable warranty time period.

ii. 

Proof of the installation date by a licensed contractor is required when requesting warranty service. Present the sales receipt, building permit or other document 

which establishes proof and date of installation. In the absence of acceptable proof, this Limited Warranty shall be deemed to begin one hundred twenty (120) 

days after the date of manufacture stamped on the System/Products.

iii. 

This Limited Warranty applies only to System/Products purchased on or after February 1, 2021 only while the System/Products remains at the site of the original 

installation, and only to locations within the continental United States, Alaska, Hawaii and Canada.

iv. 

Shipment, to the Manufacturer, of that part of the Product thought to be defective. Goods can only be returned with prior written approval from the Manufacturer. 

All returns must be freight prepaid. Determination, in the reasonable opinion of the Manufacturer, that there exists a defect in material or workmanship.

b. 

THIS LIMITED WARRANTY DOES NOT COVER: property damages, malfunction or failure of the System/Products, or personal injury caused by or resulting from: 

(a) accident, abuse, negligence or misuse; (b) operating the System/Products in a corrosive or wet environment, including those containing chlorine, fluorine or any 

other hazardous or harmful chemicals or environmental factors, including sea- or salt-water; (c) installation, alteration, repair or service by anyone other than a licensed 

contractor or other than pursuant to the manufacturer’s instructions; (d) improper matching of System/Products components; (e) improper sizing of the System/Products; 

(f) improper or deferred maintenance contrary to the manufacturer’s instructions; (g) physical abuse to or misuse of the System/Products (including failure to perform any 

maintenance as described in the Operation manual, or any System/Products damaged by excessive physical or electrical stress; (h) System/Productss that have had a 

serial number or any part thereof altered, defaced or removed; (i) System/Products used in any manner contrary to the Operation Manual; (j) freight damage; or (k) events 

of force majeure or damage caused by other external factors such as lightning, power surges, fluctuations in or interruptions of electrical power, rodents, vermin, insects, 

or other animal- or pest-related issues.

c. 

THIS LIMITED WARRANTY ALSO EXCLUDES: (a) SERVICE CALLS WHERE NO DEFECT IN THE SYSTEM/PRODUCTS COVERED UNDER THIS WARRANTY 

IS FOUND: (b) System/Products installation or set-ups; (c) Adjustments of user controls; (d) System/Productss purchased or installed outside the continental United 

States, Alaska, Hawaii and Canada; or (e) System/Productss purchased or installed prior to February 1, 2021. Consult the operating instructions for information 

regarding user controls.

Limited Warranty

Содержание SIS Series

Страница 1: ...55 TRANMERE DRIVE MISSISSAUGA ONTARIO L5S 1L4 905 670 5888 SECTION 1 PREFACE 2 SECTION 2 UNIT SPECIFICATIONS 3 SECTION 3 INSTALLATION 6 SECTION 4 WIRING 22 SECTION 5 CONTROL 26 SECTION 6 OPERATION 28 SECTION 7 MAINTENANCE TROUBLESHOOTING 38 SIS SERIES SPLIT INVERTER AIR TO WATER HEAT PUMP ...

Страница 2: ...the heating or cooling load It contains an Enhanced Vapor Injection compressor for maximum performance in extreme heating conditions and is installed in a split configuration keeping all water and plumbing indoors with only the compressor fan and airside heat exchanger located outdoors Advanced Controls Unit function is managed by a parametric microprocessor allowing on site adjustment to tune the...

Страница 3: ...should be applied to the unit at least 8 hours prior to starting in heating or cooling This will allow crankcase heater time to boil refrigerant out of compressor oil 9 Electrical box Wire holes 4 4 5 Model P10 O Valve cover 6 1 7 3 Electrical box 2 4 5 Wire holes Valve cover 1 3 6 7 Unit mm Models 1 2 3 4 5 6 7 SISO 060A4 93 5 1390 87 5 397 380 650 900 Electrical components behind panel Wire hole...

Страница 4: ...nit Specifications Inverter Ultra Low Temperature Air Source Heat Pump Water Heater Figure 2 2 Indoor Unit 17 3 13 6 Wall 29 5 Wire holes 1 NPT Water in Return 5 8 SAE Flare R410A Connection 3 8 SAE Flare R410A Connection 1 NPT Water Out Supply ...

Страница 5: ... 8 5GPM All data based on pure water Heating Cooling HZ Water Temp Ambient Capacity kW COP HZ Water Temp Ambient Capacity kW EER 90 100 20 35 967 6 28 1 68 78 45 76 74 489 5 19 14 34 4 42 109 6 46 1 91 89 66 912 5 89 11 36 17 50 609 6 75 2 20 95 63 125 6 38 9 90 47 76 023 7 26 3 07 101 58 449 6 79 8 60 120 20 33 863 7 50 1 32 60 76 60 396 5 09 11 87 4 39 645 7 70 1 51 89 54 253 5 77 9 40 17 47 648...

Страница 6: ...ntamination at the liquid input of the heat pump as shown in this manual to protect the internal components from damage or fouling due to contaminants or sediment DO NOT use the heat pump for DIRECT heating of potable water The heat exchanger and internal components are not suitable for this application Never expose the SIS Hydronic circuit to pressures in excess of 60 PSI Loss of coolant property...

Страница 7: ...l installations must have total circulating volumes equal to or greater than 7 5 gallons per nominal ton of the unit performance at minimum capacity The greater of either heating or cooling produced In other words in the case of a five ton heat pump with 3 to 1 turndown 0 33x rated capacity the minimum total system volume is 5x0 33x7 5 12 5 gal Multiple heat pump installations that are operating i...

Страница 8: ...ater supply to the system fill hose bib Note the drain port can be used for this purpose The hose bib purge drain valve should be located low in the system and close to the SIS return connection 2 Open the high point purge valve not shown in illustration as it may be inside the air handler while slowly filling the system Close the valve when air is removed from the system and water begins to flow out...

Страница 9: ...ptance Inspection Preparations before Installation Upon receipt of the goods the user shall inspect the unit carefully to confirm that no damage has occurred during the transport that the screws are not loose and that all spare parts have been received If there is damage please reject the goods For the outdoor unit as shown in Figure 1 the weight is concentrated on the label side When handling and...

Страница 10: ...nt so as to ensure that the space around the outdoor units does not affect the installation of return air air outlet system piping and other devices The following arrangement is for reference Installation space for single outdoor unit unit mm 500 500 1000 Unconfined space Installation space for multiple outdoor units Unit mm 500 1000 1000 800 400 400 400 Air out Air out Air out 3000 Do not cover t...

Страница 11: ...ation of piping and electrical connections Please reserve enough space for maintenance of the unit 6 If the unit is mounted on the wall it is necessary to take good drainage protection measures to prevent icing in winter due to low temperature which may drop and cause injury 800 Water and snow proof shelter diagram unit mm IndoorUnit 1 The unit installation site must be able to withstand the weigh...

Страница 12: ...ss than 150mm IndoorUnit 1 Selecta wallthatcanwithstandweightoftheunitwithoutincreasingoperationnoiseandvibration 2 Fixthehangingbeamoftheaccessoryboxhorizontallyonthewall 3 Place the ribs of the unit on the hanging beam and pay attention to the distance to the ground and the risk distance betweentwoendsoftheunit 4 Correctlyinstalltherubbergasketandtheirongasket anduseexpansionscrewstofix Hanging ...

Страница 13: ...ten the connection pip nut firmly with a wrench The standard connection pipe is long in 5 meters Connect the connection pipe first to the indoor unit and then to the outdoor unit The piping should be carefully arranged so as not to damage the connection pipe Make sure tightening torque of the nut is in accordance with the following table otherwise it will cause leakage A layer of cotton insulation...

Страница 14: ...he maximum length of the pipe is 10 meters The length can be selected to the customer s needs And the unit installation is optional with two solutions Indoorunitovertheoutdoorunitwitha dropof10m 开关 Indoorunitundertheoutdoorunitwitha dropof10m 开关 Unit fixing install dampi ng device Installation Instructions Install Connection Pipe The maximum length of the pipe is 10 meters The length can be select...

Страница 15: ...rafter use either metal strapping material or anchored heavy nylon wire ties 8 FEET 2 43 METERS STRAP THE VAPOR LINE TO THE JOIST OR RAFTER AT 8 FEET 2 43 METERS INTERVALS THEN STRAP THE LIQUID LINE TO THE VAPOR LINE FLOOR JOIST OR ROOF RAFTER REFRIGERANT LINE SET INSTALLING HORIZONTAL RUNS NOTE Similar installation practices should be used if line set is to be installed on exterior of outside wal...

Страница 16: ...ng system use a regulator that can control the pressure down to 1 or 2 psig 6 9 to 13 8 kPa WARNING Refrigerant can be harmful if it is inhaled Refrigerant must be used and recovered responsibly Failure to follow this warning may result in personal injury or death TO VAPOR SERVICE VALVE HFC 410A MANIFOLD GAUGE SET OUTDOOR UNIT HIGH LOW NITROGEN A With both manifold valves closed connect the cylind...

Страница 17: ...inue to evacuate the line set and indoor unit until the absolute pressure does not rise above 500 microns 29 9 inches of mercury within a 20 minute period after shutting off the vacuum pump and closing the manifold gauge valves F When the absolute pressure requirement above has been met disconnect the manifold hose from the vacuum pump and connect it to an upright cylinder of HFC 410A refrigerant ...

Страница 18: ...dedwithexhaustvalvestoremoveair from thepipes Exhaustvalvesanddrainagepipeinterfacesarenotinsulatedtofacilitatetroubleshooting 4 The inlet and outlet pipe connectors of the unit have been installed with fixed sheet metal When connecting water pipes use pipe clamps to fix the connectors on the unit and rotate to connect water pipes The connecters cannot directly withstand the rotational torque 5 Se...

Страница 19: ...K AUTOFILL LOCATION IS SUGGESTED BUT THE FINAL LOCATION TO BE MADE BY FIELD CONTRACTOR DRAIN VALVE SHOULD BE LOCATED AT LOWEST POINT IN PIPING SYSTEM RETURN FROM TERMINAL UNIT S SUPPLY TO TERMINAL UNIT S SPACEPAK SPACEPAK SISO 060 OUTDOOR MODULE SISI 060 INDOOR MODULE REFRIGERANT LINESET SUPPLIED MAX LENGTH 35 BOILER DHW TANK OPTIONAL POTABLE WATER IN DOMESTIC HOT WATER OUT DHW LOOP OPTIONAL 3 WAY...

Страница 20: ...rately and cannot interfere with each other It is not permitted to connect multiple wires in parallel The wire must not contact heat generating movable parts such as refrigerant piping compressors and fans 6 The fuse type and rating of the controller are based on the silkscreen identification on the corresponding controller or fuse bushing 7 The voltage fluctuation range of the unit shall not exce...

Страница 21: ...cation Table allow for a pump load of no more than 5 amps at 110 VAC 2 5 amps at 230 VAC If the pump load exceeds this provide a separate power source to the pump DO NOT feed power to the pump from the SpacePak air handler panel SIS Control Wiring Connection The SpacePak SIS requires a dry contact relay signal to enable and select between heating and cooling modes They will not operate on the 24V ...

Страница 22: ...OTORS FAN SPEED CONTROLLER CN14 BLK BLK YEL RED COMPRESSOR SPEED CONTROLLER BLK WHT L2 L1 L2 L1 L1 IN L2 IN W V U P1 P2 PE ACNACL L1 L2 W V U COMP KM1 PTC PTC POSTITIVE TEMPERATURE COEFFICIENT OVERCURRENT PROTECTION EMI FILTER BOARD 01 L2 L2 L2 L1 OUT L2 OUT CRANKCASE HEATER CONDENSATE PAN HEATER REVERSING VALVE 4V SUT 10k EIT 10k EOT EEV EIV COMMUNICATION TO INDOOR MODULE 10k 10k CT AT 10k ET 10k...

Страница 23: ... 23 Split Inverter Air to Water Heat Pump Wiring Figure 4 2 ...

Страница 24: ... 24 Split Inverter Air to Water Heat Pump Wiring with SSIC Controller Figure 4 3 ...

Страница 25: ... input 8 AI05 Ambient temp sensor Input 9 AI07 Return air temp sensor input 10 AI08 Coil temp sensor input 11 AI10 EVI inlet temp sensor input 12 AI11 EVI outlet temp sensor input 13 AI21 Return air pressure sensor 14 AI22 Discharge pressure sensor 15 DI01 High pressure switch 16 DI02 Low pressure switch 17 DI04 Remote switch 18 DI05 Mode switch 21 CN1 Expansion valve interface 22 CN2 EVI interfac...

Страница 26: ... 26 Split Inverter Air to Water Heat Pump Section 5 Control Easy touch screen display panel allows users to change between heating and cooling modes as well as access parameter and faults Figure 5 1 ...

Страница 27: ...when the circulation pump is running Fan symbol It will display when the fans are running Mute symbol When the timing mute function is started it keeps bright for a long time When it is in mute state it will flash Or else it is off Timing symbol It will display after the user sets the timing and multiple timing intervals can be set Locking key symbol When the keyboard is locked it is on Fault symb...

Страница 28: ...frost Compressor Fan Water Pump Electric Heating Four way Valve BasicFunctions 1ON OFF Long press for 3s to power on Long press for another 3s to power off 2Mode Long press M for 3s to switch to Cooling and Heating Temp eratur e adjust ment Cooling temperature adjustment range 41 77OF Press Up arrow to increase the water temperature press Down arrow to decrease the water temperature press Mode to ...

Страница 29: ...Up or Down arrow to switch what to be viewed and press ON OFF to exit to the main interface From home screen Long Press Search for 3s to view system status Press Up down arrow to switch the system status to be viewed Long press Mode key for 3s to view fault records Press Up or Down arrow to switch what to be viewed and press ON OFF to exit to the main interface Value Number Heat From home screen L...

Страница 30: ...turn to the main interface Long press Lock Screen for 3 seconds to lock the screen Long press for 3 seconds again to unlock As screen is locked pressing other keys is invalid It is recommended to lock the screen after completing the settings to avoid inadvertent touching Operation Instructions 7Time Long press for 3s to enter time settings Press the Up down arrow to adjust time 8Lock reen You can ...

Страница 31: ...FF function is controlled by wire controller When the unit is off press key for 1 second to start it up When the unit is on press key for 1 second to shut it down Description of operation 1 On the shutdown interface you can do any operation as same as on the booting interface 2 You can only operate the on off key on the main interface 3 When the screen is off you can press any key to turn back the...

Страница 32: ...own key it will enter temperature setting interface The setpoint will change by pressing Up or Down key Short press Up or Down key Short press on off key will return 4 State parameter query For single system unit it needs to press M key for one time For double or triple system unit it needs to press M key for two times Then it will go into status interface Press up or down key will see the S1 S2 S...

Страница 33: ...t press clock icon to back to main screen Hour digits flashing Short press clock key Short press up or down to change the minute digits 9 1 On the main interface short press M key to enter the parameter query interface 2 On the query parameter interface it is not allowed to automatically return to the main interface It need to short press the ON OFF key to return 5 Clock setting Under the main int...

Страница 34: ...rost curve D07 Coil Temp Spread of Defrost Curve Deg F 32 to 86 32 Coil temp range above D05 of Defrost Curve D08 Not used D09 Enable Defrost Reset N A 0 1 1 0 Fixed Defrost per D04 1 Defrost Reset per D05 D06 D07 D10 Aux Electric Heat during Defrost N A 0 1 0 0 No Aux Heat during Defrost 1 Aux Heat during Defrost D11 Compressor Speed during Defrost Hz 30 to 90 70 Fixed compressor speed during Def...

Страница 35: ... of R15 R03 Difference from setpoint to Start Cooling Deg F 0 to 18 6 Compressor starts in cooling when water temp rises to R01 R03 R04 Difference from setpoint to End Cooling Deg F 0 to 18 2 Compressor stops in cooling when water temp falls to R01 R04 R05 Difference from setpoint to Start Heatling Deg F 0 to 18 10 Compressor starts in Heat when water temp falls to R02 R05 R06 Difference from setp...

Страница 36: ...ror interface Error record Error code Error serial number Compressor Pump Fan Figure 6 6 SIS 060 Defrost Control The SIS 060 is factory configured to operate the defrost function on a sliding scale The controller monitors the outdoor ambient temperature shown below on the horizontal scale and compares it to the coil temperature shown on the vertical scale It then compares the two according to save...

Страница 37: ...he heat pump by a suitable heat exchanger rated for potable water use The heat exchanger inside the SIS 060 is not suitable for contact with potable water Control Parameter Settings Setting the parameter H11 to a value of 1 enables the DHW mode Parameter R11 is the DHW setpoint This is the temperature of the isolated potable water loop not the hydronic loop passing through the SIS 060 Heat Exchang...

Страница 38: ...nig airflow should be addressed Ensure Defrost function is enabled and adjusted for local condtions Innacurate Coil Temperature Sensor Verify Status reading temperature 06 against known device placed on coil outlet plumbing Reduced Cooling Capacity Insufficient water flow Ensure the pump is in good operating conditon and is able to provide at least 12 GPM against the entire system pressure drop Ch...

Страница 39: ...ssure Switch failed or disconnected Circuit does not close when pressure returns to normal Repair wiring or replace switch E03 Flow Switch Insufficient Water Flow Check pump size and operation remove air from the system Purge air and provide sufficient water flow Switch failed or disconnected Confirm switch closes when flow is correct Check wiring Repair wiring or replace switch E19 19 Indoor plum...

Страница 40: ...d fault Communication fault Check communication wires cycle power Repair or replace control wire connections E38 DSP and PFC board fault Communication fault Check communication wires cycle power Repair or replace control wire connections E39 Abnormal voltage sampling Electronic control fault Contact Technical Support Replace inverter driver board E40 EEPPROM fault Electronic control fault Contact ...

Страница 41: ...45W09 WG1328 01 REACTOR EMI x 45W09 WG1329 01 FILTER INVERTER EMI x 45W05 WG1330 01 PLUG RUBBER x 45W40 WG1331 01 TEST PORT HIGH PRESSURE x 45W19 WG1332 01 INSERT LIFT HANDLE x 45W40 WG1333 01 ADAPTER CONDENSATE DRAIN x 45W41 WG1334 01 PANEL CORNER ACCESS x 45W28 WG1335 01 SHUT OFF VALVE VAPOR x 45W41 WG1336 01 PANEL FRONT ACCESS x 45W41 WG1337 01 BRACKET HEAT EXCHANGER x 45W28 WG1338 01 SHUT OFF ...

Страница 42: ... parts must be made available to SpacePak in exchange for the replacement parts and become the property of SpacePak SpacePak Buffer Tanks The Manufacturer warrantstotheoriginalownerattheoriginalinstallationsitethattheHydronicBufferTanks the Product willbefreefromdefectsinmaterialorworkmanship for a period not to exceed ten 10 years from the startup provided the product is installed in accordance w...

Страница 43: ... 43 Split Inverter Air to Water Heat Pump ...

Страница 44: ...IN UNITED STATES 260 NORTH ELM ST WESTFIELD MA 01085 800 465 8558 IN CANADA 7555 TRANMERE DRIVE MISSISSAUGA ONTARIO L5S 1L4 905 670 5888 ...

Отзывы: