background image

 

Cranking Voltage Test 

This test identifies excessive starter current draw, which makes starting difficult and shortens 

battery life. Perform battery load test and proceed if battery is good. 

ENGINE MUST BE AT NORMAL OPERATING TEMPERATURE. 

1. 

Connect tester clamps to battery as described in Steps 1-2 under Battery Load Test. 

2. 

Disable the ignition so the car will not start. 

3. 

Crank the engine and note the voltage reading during cranking. 

4. 

A display reading of 9 volts or less indicates excessive current draw. This may be due 

to bad connection of a failing starter motor; or the battery is too small for the vehicle’s 

requirements. 

Charging Voltage Test 

This test measures the output voltage of the alternator/regulator. Check for under or overcharging: 
The ENGINE SHOULD BE AT NORMAL OPERATING TEMPERATURE. 
1. 

Connect tester clamps to battery as described in Steps 1-2 under Battery Load Test. 

2. 

Turn off all lights and accessories. Operate engine at fast idle (approximately 1500 RPM). 

3. 

Do not operate tester’s load switch. 

4. 

Read the displayed voltage and you can acquire one of following results: 

 

Measured voltage < 13.5 volt → No good. Check alternator. 

 

Measured voltage > 13.5 volt, but < 15 volt → Okay 

 

Measured voltage > 15 volt → No good. Please check regulator. 

5. 

Turn headlights on - high beam and repeat same test No. 4 as above.  

 

Cleaning and Maintenance 

 

Clean the grips after each use and wipe off any battery acid that may have come in contact with 

the clamps to prevent corrosion.  

 

 

Keep your Load Tester / Analyser dry, clean and free from oil, water and grease. 

 

 

Use a mild detergent on a clean cloth to clean the outside of the tool, when necessary. 

 

 

Store the unit in a dry dust free environment. 

 

Disposal & Recycling Information 

When the tool reaches its end of life, take it to a collection point designated by local authorities for 

E-waste.  

 

The separate collection and recycling of your product at the time of disposal will help conserve 

natural resources and ensure that it is recycled in a manner that protects human health and the 

environment.

 

 

 

 

                             AFTER SALES SUPPORT  

                     

                   1300 730 056                                          

 

[email protected] 

Содержание SP61009

Страница 1: ...NS AND ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRALIA...

Страница 2: ...of Delivery 4 Safety Precautions Warnings 4 Tool Description 5 Operating Instructions 6 Voltage Explanation 6 Before Testing 7 Product Set up 7 Battery Test 8 Battery Load Test 8 Cranking Voltage Tes...

Страница 3: ...reduced service life of battery Starter Motor Test This test is used to motor analyse the starter motor By testing the actual cranking current and cranking voltage of the starter motor it is possible...

Страница 4: ...intended for use on automotive or marine 12volt batteries i e Lead Acid AGM Flat Plate or AGM spiral Gel and EFB It has been constructed for trade or commercial use in dry non explosive environments...

Страница 5: ...batteries will freeze during cold weather Never test or charge a frozen battery 12 To insure a good connection clean battery terminals with a solution of water and baking soda IN CASE OF ACCIDENTAL CO...

Страница 6: ...llow the battery charge to stabilise then test Even when testing an in vehicle battery after the engine is turned off for the most accurate results wait 10 minutes before testing 4 In general if the b...

Страница 7: ...not cause any adverse effects In order to ensure a good electrical connection with no resistance please wiggle the test clips on the terminal posts a few times when connecting The tester draws its ope...

Страница 8: ...CHARGE If state of charge is less than 12 0 volts the battery should be recharged before load testing If recharging does not bring voltage more than 12 0 volts battery is defective If state of charge...

Страница 9: ...at fast idle approximately 1500 RPM 3 Do not operate tester s load switch 4 Read the displayed voltage and you can acquire one of following results Measured voltage 13 5 volt No good Check alternator...

Страница 10: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...

Отзывы: