If testing batteries of low-frequency use, it is necessary to cycle (charge and discharge) the 

battery several times before testing, normally 3-5 times will achieve a reliable test result. Only 

after cycling the battery can the chemical properties of the battery be restored. This is 

particularly important after long periods of no use. If after 3-5 times of battery charge and 

discharge, the battery health state is still lower than 60%, battery replacement should be 

considered. 

 

1. 

To extend battery life, Low use batteries, should be recharged every 2 months. 

 

2. 

Please turn off the engine before testing. 

 

3. 

When charging is finished, do not test immediately. Wait at least 10 minutes to allow the 

battery charge to stabilise, then test.  Even when testing an in-vehicle battery, after the 

engine is turned off (for the most accurate results) wait 10 minutes before testing.  

 

4. 

In general, if the battery voltage is below 12.40V, recharge it. 

 

Battery Voltage Explanation 

 

 

Fully charged = Battery voltage above 12.59V  

 

75% charged = Battery voltage 12.45V 

 

50% charged = Battery voltage 12.15V  

 

Discharged condition = Battery voltage less than 12.00V 
 

Cold Temperature Effects 

Because of the battery’s chemical nature, it will test lower when cold than when warm. 

For most accurate results, this effect should be compensated for when the battery’s 

internal temperature is below 5

.  Assume internal battery temperature to be the 

day’s high-low average.  

 

20           30            40            50            60           70           80           90          100%

(¡ ãF)      -20         -10     0    +10         +20          +30       +40          +50          +60   +70 

(¡ ãC)      -29         -28   -18    -12        -6.7          -1.1       +4.4         +10         +15.6 +21.1 

Internal Battery Temperature

Test At This Percentage Of Rated Capacity

Содержание SP61009

Страница 1: ...NS AND ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRALIA...

Страница 2: ...of Delivery 4 Safety Precautions Warnings 4 Tool Description 5 Operating Instructions 6 Voltage Explanation 6 Before Testing 7 Product Set up 7 Battery Test 8 Battery Load Test 8 Cranking Voltage Tes...

Страница 3: ...reduced service life of battery Starter Motor Test This test is used to motor analyse the starter motor By testing the actual cranking current and cranking voltage of the starter motor it is possible...

Страница 4: ...intended for use on automotive or marine 12volt batteries i e Lead Acid AGM Flat Plate or AGM spiral Gel and EFB It has been constructed for trade or commercial use in dry non explosive environments...

Страница 5: ...batteries will freeze during cold weather Never test or charge a frozen battery 12 To insure a good connection clean battery terminals with a solution of water and baking soda IN CASE OF ACCIDENTAL CO...

Страница 6: ...llow the battery charge to stabilise then test Even when testing an in vehicle battery after the engine is turned off for the most accurate results wait 10 minutes before testing 4 In general if the b...

Страница 7: ...not cause any adverse effects In order to ensure a good electrical connection with no resistance please wiggle the test clips on the terminal posts a few times when connecting The tester draws its ope...

Страница 8: ...CHARGE If state of charge is less than 12 0 volts the battery should be recharged before load testing If recharging does not bring voltage more than 12 0 volts battery is defective If state of charge...

Страница 9: ...at fast idle approximately 1500 RPM 3 Do not operate tester s load switch 4 Read the displayed voltage and you can acquire one of following results Measured voltage 13 5 volt No good Check alternator...

Страница 10: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...

Отзывы: