14
1000W
1000
9
180-260 or 90-140
220 or 120
50/60
48-52/58-62
1200W
1200
6
After connected all the machines,Follow those steps to start the Mrcro
Inverter :
7.Appendix A
7.1
(1)Make sure the Inverter is connected in the correct way.
(2)Make sure the polarity of the solar array is right.
(3)Make sure the AC connector and DC connector are connected well.
technical datas
After finish the previous steps, the gird voltage and DC side
voltage is normal the micro-inverter will automatically start
parallel operation.
DC input parameters
Recommended solar panel
board power uses (W)
DC in branch numbers
Max DC Input Power(W)
MPPT Tracking Range(V)
Wide DC input voltage
range(V)
Max Input Current(A)
AC output parameter
Max AC Current (A)
AC Voltage (V)
AC Voltage Range(V)
AC Frequency(Hz)
AC Frequency Range(Hz)
*
Rated Current
Output Power
W
( )
Type Specification
1
920 1120
-
50-86 / 85-125 / 120-180 / 170-220
1100
38-65 / 84-95 / 88-125 / 128-168
20
1
1150 1300
-
1300
20
*
Appendix
220
180-260