5
Step5: Click the page of DI Input V.S. Relay Output Connection.
3.3 DI Input V.S. Relay Output Connection setting of 701E Parameter
1. The DI.1 is exit button input of WG port 1 and the K1 is open door relay.
(1) Choose “DI 1” under the menu item.
(2) Click “K1”.
2. The DI.2 is exit button input of WG port 2 and the K2 is open door relay.
(1) Choose “DI 2” under the menu item.
(2) Click “K2”.
Note: Active second can be set only when the window is DI 1.
If DI1 is used for exit button input of WG port 1, DI1 to Active Release All Doors
function will be disable.
3.4 Weigand reader LED and Buzzer indicators
1. LED light green and one beep sound mean acknowledge, LED light green twice and
two beep sounds mean not acknowledge.
2. In anti-pass-back access mode, LED light green five times and five beep
sounds mean violates access function.
3. When access modes have entering user code, after flash card, LED light green four
times and four beep sounds mean that reader wait for being entered the 4-digit user
code.
DI.2
DI.1
COM
DI.4
DI.3
V12
K1
K2
K3
K4
COM
CN4
D12
JP4
CN5
D10
D11
D9
RELAY
RELAY
K1
K3
K2
K4
RELAY
RELAY
K3
COM
K4
CN4
K2
K1