Flush-Mount Backlight Multi-Function Controller / Flush Mount Illuminated Access Reader
Function Default Value
AR-888-H
20 DDD
Function
Selection
Value Application
※
Default Value
Time Attendance
Auto Relock
Auto Open
Exit by RTE Button
Master Controller of Network
Entrance/Exit
Anti-pass-back
※
0: Yes
※
0: Disable
※
0: Disable
0: Disable
※
0: Slave
※
0: Exit
※
0: Disable
Networking
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking
Networking
Networking
001
002
004
016
032
064
128
1: No
1: Enable
1: Enable
※
1: Enable
1: Mater
1: Entrance
1: Enable
24 DDD
Function
Selection
Value Application
※
Default Value
Auto Open without Presenting in Auto-open Time Zone
Alarm Output/ Lift Control
Stop Alarm by pressing RTE Button or Closing the Door
Doorbell
※
0: Disable
※
0: Alarm Output
0: None
※
0: Disable
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
001
002
064
128
1: Enable
1: Lift Control
※
1: Yes
1: Enable
28 DDD
Function
Selection
Value Application
※
Default Value
Double Door Control
Force Open Alarm Output
※
0: Disable
0: Disable
Networking/Standalone
Networking/Standalone
064
128
1: Enable
※
1: Enable
Select the desired function, Weighted Value =
Selection Index (0 or 1) x Value.
[e.g.] DDD (total weighted value of all functions):
Enable "Auto Open" + "Exit by RTE Button" + "Anti-
pass-back"=1*004 + 1*016 + 1*128=148; As a result
of that, the command will be 20 148 .
34 DDD
Function
Selection
Value Application
※
Default Value
Enable the RF after door sensor closed to GND
Invalid card to activate alarm relay
Turn off all sounds of beeper
Mute the sounds of egress button (RTE)
Reserved
Keep beeing while arming is enabled
Door relay connected to AR-721RB (suited to models without relay built-in)
Arm relay connected to AR-721RB (suited to models with relay built-in)
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
001
002
003
004
016
032
064
128
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
Enable:
Enter program mode
→
After door open :
The normal procedure to open door
→
Input 4-digit arming PWD
→
Disable:
Enter program mode
→
Do not open the door
:
→
Input 4-digit arming PWD
→
Present a valid card
Enable/Disable Arming status
(for M4/M8)
:
More Details:
SOYAL Security Related Function
※
[The normal procedure to open door] can refer to [Access Mode].
※
Read the [Command List-Arming /Duress Function Setting] below to modify arming PWD.
※
M6 is Standalone Mode, the mode is without Arming /Duress Function.
Enter Programming Mode
Without Enter Programming Mode (Standby Mode): Enter Arming Code
(
default value of arming PWD is: 1234
)
Factory Reset by its commands
Reset User Data
Reset User Data &Controller Parameter
(incl. Master Code)
Reset User Data &Controller Parameter
(incl. Master Code) & Reset Parameter Setting- SOR
Enter program mode
→
29
29
→
Exit the programming mode
Enter program mode
→
29
20
→
Exit the programming mode
Enter program mode
→
29
21
→
Exit the programming mode
※