SOYAL
ACCESS & INDUSTRIAL CONTROL
®
AR-888(H/K/U)
V221012
- 11 -
www.soyal.com
Description
Please refer to function default value for details.
N
= 0 (1st time zone) / 1 (2nd time zone)
HHMM
= Starting time;
hhmm
= ending time
(i.e.: 08301600=08:30 to 16:00)
7123456H
= 7 days of week (Sun/Mon/Tue/Wed/Thu/Fri/
Sat)+ Holiday(H= 0: disable; 1: enable); Holidays can be
set by 701Client software.
SSSSS
=Starting User Address;
EEEEE
=Ending User Address;
N
=0: Enable;
N
=1: Disable;
N
=2: Reset
After enabling keypad lock function, press any button will
only has two beeps and no reaction. Disable the keypad
lock function will bring controller keypad function back to
normal. (only Keypad Controllers have this function ex.
AR-721-H; Touch Keypad Controllers do not have this
function ex. AR-725-H)
UUUUU
=User Address, S=4 sets of lift control (0~3);
FFFFFFFF
=8 assigned floor(F=0: Disable, 1: Enable)
NNN
=site number,
TTT
= relay time: 000~600=1~600 sec.
UUUUU
=User Address;
FF
=Floor (01~32 floor)
Command
20 DDD
24 DDD
28 DDD
08 N HHMMhhmm 7123456H
26 SSSSS EEEEE N
(simultaneously)
24 002
21 UUUUU S FFFFFFFF
23 NNN TTT
27 UUUUU FF
Controller
Additional
Function
Setting
Lift
Control
Setting
Exit
Program
Mode
Function
Reader additional setting
Controller parameter setting
Double Door Control / Force Open Alarm
Auto-open time zone setting
Anti-pass-back (Enable user)
Enable/Disable keypad lock
Controller parameter setting
Lift control setting: multi-floor(M4/M8)
AR-401RO16 Lift Relay Activated TM
(M4/M8)
Lift control setting: single floor
(M4/M8)
Exit program mode
Exit program mode and enter arming
mode(M4/M8)
※
More Details
:
Introduction of New Function Commands for Enterprise E Controller and Home H Controller