Soyal AR-723 H Скачать руководство пользователя страница 6

V220624

   

Access Controller

- 6 -

   

Function

Control mode setting

Card or PIN (M4/M8)

Modify the PIN with user address, change 

the pass mode into Card or PIN

Card and PIN (M4/M8)

Modify the PIN with user address, change 

the pass mode into Card and PIN

Card or PIN(M6)

Set up the mutual PIN in Card or PIN mode

Card and PIN(M6)

Set up the mutual PIN in Card and PIN mode

Setting duress PWD(M4/M8)

Setting arming PWD(M4/M8)

Node ID setting 

(Connected to 716E)

(M4/M8)

Node ID setting 

(Connected to the PC directly 

without 716E)

 (M4/M8)

Door Relay Time setting

Alarm Relay Time setting

Arming Delay Time setting

Alarm Delay Time setting

Arming Pulse Time setting
Door Close Time

Controller time clock setting

Same tag reading interval time

Reader additional setting
Controller parameter setting
Double Door Control / Force Open Alarm

Auto-open time zone setting

Anti-pass-back (Enable user)

Enable/Disable keypad lock

Controller parameter setting

Lift control setting: multi-floor(M4/M8)

AR-401RO16 Lift Relay Activated TM 

(M4/M8)

Lift control setting: single floor

(M4/M8)

Exit program mode

Exit program mode and enter arming

mode(M4/M8)

Command

 04     N

12     UUUUU     PPPP

13     UUUUU     PPPP

15     PPPP

17     PPPP

15     PPPP

17     PPPP

00     NNN

00     NNN     VVV     nnn

02     TTT

03     TTT

05     TTT

06     TTT

14     TTT
18     TTT
25     YYMMDDHHmmss
31     TTTT

20     DDD
24     DDD
28     DDD

08     N     HHMMhhmm     7123456H

26     SSSSS     EEEEE     N

             

(simultaneously)

24     002      

21     UUUUU     S     FFFFFFFF

23     NNN      TTT

27     UUUUU       FF

                 

Description

N=4: M4; N=6: M6; N=8: M8
Pass by Card or PIN; 

UUUUU

=User Address;

PPPP

=4-digit PIN (0001~9999); 

0000=Set as card only
Pass by Card and PIN; 

UUUUU

=User Address;

PPPP

=4-digit PIN (0000~9999)

PPPP

=4-digit PIN(0001~9999 ; default value=4321)

PPPP=

4-digit PIN(0001~9999 ; default value=1234)

0000= Set as card only

PPPP

=4-digit PIN(0001~9999 ; default value=4321)

PPPP

=4-digit PIN(0001~9999 ; default value=1234)

NNN

=Node ID of Access Controller (range: 001~016)

NNN

=Node ID of Access Controller (range: 001~254) 

VVV

=Virtual 716E Node ID, 

nnn

=Door number (range:001~254)

TTT

=Door relay time   000= Output continuously

                                     001~600=1~600 sec.

                                     601~609=0.1~0.9 sec.

TTT

=Alarm relay time  000= Output continuously  

001~600=1~600 sec.

TTT

=the buffer time before entering arming mode  

001~600=1~600 sec.

TTT

=the buffer time before the alarm is activated  

001~600=1~600 sec.

TTT

=Arming output time; 000=output continuously 

001~250=0.1~2.5 sec.

TTT

=Door Close Time: 001~600=1~600 sec.; 

default value: 15 sec. 

YYMMDDHHmmss

=Year/ Month/ Day/ Hour/ Min./ Sec.

TTTT

=10~6000 (Base on 10ms, range from 10 to 6000; 

default value: 1 sec.

0100)

Please refer to function default value for details.

N

= 0 (1st time zone) / 1 (2nd time zone)

HHMM

= Starting time; 

hhmm

= ending time

(i.e.: 08301600=08:30 to 16:00)

7123456H

= 7 days of week (Sun/Mon/Tue/Wed/Thu/Fri/

Sat)+ Holiday(H= 0: disable; 1: enable); Holidays can be 
set by 701Client software. 

SSSSS

=Starting User Address; 

EEEEE

=Ending User Address; 

N

=0: Enable; 

N

=1: Disable; 

N

=2: Reset

After enabling keypad lock function, press any button will 
only has two beeps and no reaction. Disable the keypad 
lock function will bring controller keypad function back to 
normal. (only Keypad Controllers have this function ex. 
AR-721-H; Touch Keypad Controllers do not have this 
function ex. AR-725-H)

UUUUU

=User Address, S=4 sets of lift control (0~3); 

FFFFFFFF

=8 assigned floor(F=0: Disable, 1: Enable)

NNN

=site number, 

TTT

= relay time: 000~600=1~600 sec.

UUUUU

=User Address; 

FF

=Floor (01~32 floor)

Access Mode

Setting

Arming /Duress

Function

 Setting

(M4/M8 applicable

, but not M6)

Node ID

Setting

Time /Delay

 Setting

Controller 

Additional 

Function 

Setting

Lift 

Control

Setting

Exit 

Program

Mode

Отзывы: