Soyal AR-723 H Скачать руководство пользователя страница 3

SOYAL

ACCESS CONTROL SYSTEM

®

AR-723 (H)

V220624

   

   

- 3 -

Enter the program mode

Input      123456      or      PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input  

   

876112

     → 

program mode accessed

Exit the program mode

Input

Operation process

M4/M8: Individual pass code

Card or PIN:

 

Access programming mode

 → 

12     UUUUU     PPPP       [e.g. User address: 00001 and pass code: 1234, input 12     00001     1234     ]

Card and PIN:

 

Access programming mode

 → 

13     UUUUU     PPPP       [e.g. User address: 00001 and pass code: 1234, input 13     00001     1234     ]

M6: Public pass word
Card or PIN:

 

Access programming mode

 → 

15     PPPP       [Input 4-digit pass code, default value: 4321]

Card and PIN:

 

Access programming mode

 → 

17     PPPP       [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]

B. Set up the password 

[Only for connect to external K-series reader]

Master Code modification

Access programming mode

 → 

09     PPPPPPRRRRRR         [Input the 6-digit new master code twice.]

[e.g.] Set the Master code to be 876112, input  

   

123456

     → 

09     876112876112

A. Enter/ Exit Program Mode

C. Lift control

Enable

Access programming mode

 → 

24     002       [002= enable lift control]

Connect with 

AR-401RO16B

 to control floors which the user will be able to access.

[e.g.] User address NO. 168, only to the 6th and the 20th floor:

        Access programming mode

 → 

21     00168     0     00100000     

 → 

21     00168     2     00001000

Multi floors

Access programming mode

 → 

21     UUUUU     S     FFFFFFFF

[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)

Single floor

[e.g.] User address NO. 45, allow to access the 24th floor:

 

27     00045     24

Access programming mode

 → 

27     UUUUU     FF

UUUU=User Address FF=Floor number (01~32 floor)

Set

Floor/ Stop

F

8

16

24

32

0

1

2

3

F

6

14

22

30

F

7

15

23

31

F

5

13

21

29

F

4

12

20

28

F

3

11

19

27

F

2

10

18

26

F

1

9

17

25

D. Setting Up the Arming 

[Only for connect to external K-series reader]

Mode4 / Mode6 / Mode8

※ 

Mode 6,

 the number of users up to 65535, since it reads 

CARD CODE

(5 digits) only, unlike that Mode4/Mode8 read 

SITE CODE

 and 

CARD CODE

(10 digits).

If Access Mode setting to use the PIN, 

it

 

need to external the K-series Readers.

Mode Networking/

Stand-Alone

User 

Capacity

Access Mode

Auto-show 

Duty time

Event log 

Capacity

120 

Holidays

Anti 

force

Time 

Zone

Lift 

Control

Anti-pass-

back

M4

Networking/

Stand-Alone

1,024

1.Card only

2.Card and PIN 

(4-digit PIN)

3.Card or User address 

(5-digit) 

+ Individual PIN 

(4-digit 

individual PIN) 

+

Yes

1,200

Yes

Yes

No

32

Yes

M6 Stand-Alone

65,535

1.Card only

2.Card and PIN

 (4-digit public PIN= Arming PWD)

3.Card or PIN 

(4-digit public PIN= Duress code)

No

No

No

No

No

No

No

M8

Networking/

Stand-Alone

1,024

1.Card only

2.Card and PIN

 (4-digit individual PIN)

3.Card or PIN 

(4-digit individual PIN)

Yes

1,200

Yes

Yes

No

32

Yes

※ 

M6: 

the user capacity can be 65535 because it only reads 5-digits 

CARD CODE

, while in 

M4/M8

 it reads both 

SITE CODE

 and 

CARD CODE

(10 digits).

In the security management of access control system, the controller or reader status is divided into Standby Mode or Disarming Mode and Arming 

Mode. The conditions for triggering the alarm in these two modes is different, as shown in the following comparison:

Alarm conditions:

1. Door is forced open

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: Arming is enabled and the power is suddenly off then on.