SOYAL
ACCESS CONTROL SYSTEM
®
AR-723 (H)
V220624
- 5 -
Factory Reset by its commands
When the device is stand-alone (not networking)
Access programming mode
→
20
016
→
24
064
→
26
00000
01023
1
→
28
000
→
29
29
※
Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.
Selection= 0(none value)/ 1(1 x each value)
[e.g.] DDD value of Enable “Auto Open” + ”Exit by Push ”Anti-pass-back”
=(0x1)+(0x2)+(1X4)+(1x16)+(0x32)+(0x64)+(1x128)=148 ; As a result of that, the command will be 20 148 .
34 DDD
Function
Selection
Value Application
※
Default Value
Enable the RF after door sensor closed to GND
Invalid card to activate alarm relay
Turn off all sounds of beeper
Mute the sounds of egress button (RTE)
Reserved
Keep beeing while arming is enabled
Door relay connected to AR-721RB (suited to models without relay built-in)
Arm relay connected to AR-721RB (suited to models with relay built-in)
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
※
0: Deactivate
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
001
002
003
004
016
032
064
128
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
Command List
Function
Enter program mode
Master code setting
Suspend tag
Delete tag
Add a batch of sequential cards by
inputting card number (M6)
Recover the suspended cards(M4/M8)
Card number modification(M4/M8)
Add card by presenting(M4/M8)
Add/Delete tag by presenting(M6)
Delete all tags
Enable/Disable Door open for any Tag
Mifare tag / card format (Optional)
(M4/M8)
Administrator Card setting
(M4/M8)
Enable the security trigger signal
( with AR-721RB)
Command
PPPPPP
09 PPPPPPRRRRRR
10 SSSSS EEEEE
10 SSSSS EEEEE
11 SSSSS EEEEE
11 SSSSS EEEEE
16 UUUUU SSSSSCCCCC
19 UUUUU QQQQQ
22 N
29 29
0
01 N
07 SSSSS EEEEE
34 DDD
Description
PPPPPP
=Master Code, default value=
123456
PPPPPP
=6-digit new master code
RRRRRR
=Reconfirm the new master code
=Suspend =Delete;
SSSSS
=Starting User Address
;
EEEEE
=Ending User Address
SSSSS
=Starting card number
EEEEE
=Ending card number
SSSSS
=Starting card number
;
EEEEE
=Ending card number
UUUUU
= User Address;
SSSSS
=5-digit site code;
CCCCC
= 5-digit card code
UUUUU
=User Address;
QQQQQ
=Card quantity (00001:
for adding a single card or a batch of random numbering cards)
N
=0(Delete tag);
N
=1(Add tag)
After enabling Door Open For Any Tag, all cards in same
frequency as controller can pass directly.
N
:
0=ISO14443A
;
1=ISO14443B
2=ISO15693
;
3=I Code1
;
4=I Code2
PS.1. Please select the transmission standard first.
2. Ensure both reader and card using the same
transmission standard.
SSSSS-EEEEE=00000-00255
(Administrator Card can enter the program mode after
present the card and press in 3 seconds,
also can exit program mode by present the card.)
Change the "Arming" to the security trigger signal,
when controller is connected with AR-721RB.
Please refer to function default value for details.
9
9
(07 Starting User Address Ending User Address )
Master
Code
Setting
Card
Setting
Commands
Additional
Card Function
Setting