Soyal AR-331-E Скачать руководство пользователя страница 7

V220922

AR-331-E/EF

SOYAL

ACCESS CONTROL SYSTEM

    

   

J. Adding / Deleting Fingerprint

K. Enable/Disable Skip Finger/Tag

Adding

How to add a finger data:

Access programming mode

 →

Place your finger on the sensor

[F=1= Adding 1 Finger data; F=2= Adding 2 Finger data; UUUUU= User address]

F

UUUUU

9

3

Deleting

UUUUU= 

User address 

Access programming mode

 →

0

UUUUU

9

3

Deleting All

Access programming mode

 →

9

99999

9

3

 

Adding 2nd/3rd Fingerprint  

→ 

Repeat 1st finger process

 

If you hear continuous "beep..." sounds when you place finger on the sensor, please release your finger from the sensor.

(Please consult detail command on page 8.)

 

Command Setting

 

Software Setting

 

Access Mode

 

Way

 40      1      NNNNN      EEEEE 

 40      3      NNNNN      EEEEE

     

Just fingerprint

      Just card control

 

FP first and then Tag

First

        

Then

  

 40      0      NNNNN      EEEEE

 40      2      NNNNN      EEEEE 

     

Just fingerprint

      Just card control

 

FP only or Tag only

Access programming mode

 → 

NNNNN

starting user address

EEEEE= ending user address

F

1+3(Default Value)

F

NNNNN       EEEEE

0

4

or

L. Adding / Deleting Fingerprint

1. For dual-fingerprint sensor module version, capactive sensor module is the only enabled way for enrolling FP.
2. For dual-fingerprint sensor module version, user just can select one of fingerprint sensor for identification and can't put two fingerprints to different sensor at the same time.

3. Extra WG keypad panel is needed for adding card or downloading data connected to PC.
4. Each finger need to be collected 

1 times

 enrolling for AR-331-E/EF.

M. The process of FP identification

1. While attached a finger on biometric sensor, there is a beep sound for starting the scanner.  Then, please don't move your finger until the 

AR-331-EF

 makes  

     another beep sound.
2. If there is a 8-beep sound after user gets access by FP, the FP data shall be reset by command 39*9*99999# under the programming mode.  

    Cautions: Before reset the FP, please backup the data from source FP first.

Adding 1 

Fingerprint 

( After Bi sound, please remove the the finger 
  from unit.  Each finger shall collect for 3 times )

(OK)

Put 1st

Finger

Bi

Long Bi

Restoring Factory Settings

Reset all device parameters and user card data

Reset User Data &Controller Parameter  :

Access programming mode

 → 

29

     

20

Reset User Data &Controller Parameter (incl. Master Code)  

& Reset Parameter Setting- SOR :

Access programming mode

 → 

29

     

21

Reset IP Setting:

Access programming mode

 →

Press 

“IP Resent Button”

 of main board for few seconds. (Reference to picture)

Reset User Data :

Access programming mode

 → 

29

     

29

※ 

After operation as above, you will hear the long reminder sound,and wait until the 

sound disappear then reset the power of the controller,the device will restore factory setting.

Содержание AR-331-E

Страница 1: ...the mounting plate Assemble the covers with the Allen key and screws accessories supplied Turn on the power and LED will light and beep will sound 4 Accessories 2 Terminal Cables 3 Tools Front Panel...

Страница 2: ...Collector Active Low Wiegand 6 Thin Green Wiegand DAT 0 Input 7 Thin Blue Wiegand DAT 1 Input WG Door Sensor 8 Orange Negative Trigger Input WG Exit Switch 9 Purple Negative Trigger Input CN2 Cable 1...

Страница 3: ...oor Relay Set up via the parameters setting Window of 701ServerSQL Electric Bolt AR 1207 Electric Bolt AR 1207 This wiring method is not eligible for Share Door Relay function set up via parameter set...

Страница 4: ...user address 103 112 Enter program mode 19 00103 00001 Present User 103 card Present User 104 card Present card Present User 111 card Present User 112 card Successfully added tags of user 103 112 Imp...

Страница 5: ...9 30am to 4 20pm on Mon Wed and Fri Access programming mode 08 10 02 09301620 01010100 setting is completed Setting up access time Access programming mode 08 MW NN HHMMhhmm 7123456H M AR 331 E EF W R...

Страница 6: ...1 2 3 4 5 6 7 L 6 14 22 30 38 46 54 62 L 7 15 23 31 39 47 55 63 L 5 13 21 29 37 45 53 61 L 4 12 20 28 36 44 52 60 L 3 11 19 27 35 43 51 59 L 2 10 18 26 34 42 50 58 L 1 9 17 25 33 41 49 57 Please refer...

Страница 7: ...for identification and can t put two fingerprints to different sensor at the same time 3 Extra WG keypad panel is needed for adding card or downloading data connected to PC 4 Each finger need to be c...

Страница 8: ...ck SIF FP5 select old AR 331EF FP file format SIF the system will automatically generate new single FP file format FP5 into 701Server folder FP5 into 701Server folder Deleting fingerprint database on...

Страница 9: ...ost it can be either A Z or 0 9 Change the log in password to lock the IP setting of Ethernet Module If the IP address of AR 331 E EF has changed We must enter the new IP address Current IP address of...

Страница 10: ...code Suspend or delete tags Suspend 10 SSSSS EEEEE Suspend Delete SSSSS starting user address EEEEE ending user address Delete 10 SSSSS EEEEE Recover tag 11 SSSSS EEEEE SSSSS starting user address EE...

Страница 11: ...ree finger data 0 Delete UUUUU user address Deleting All Fingerprint 39 9 99999 En Disable Skip Finger Tag 40 F NNNNN EEEEE First 40 1 NNNNN EEEEE Then 40 3 NNNNN EEEEE Change WG bits output format 41...

Страница 12: ...buzzer function Any error trigger alarm ex swipe invalid card Reserved Turn off 13 56MHz reading function Turn off 125kHz reading function Access valid door relay remain locked Master Slave interlock...