V220922
- 4 -
Fingerprint
Biometrics Device Access controller
Adding and Deleting Tag
Changing the Master Code
Access programming mode
→
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input
123456
→
09 876112876112
Exiting
Input
Access programming mode
→
00 NNN MMM AAA
[NNN= Node ID: 000~254; MMM=AR-331-E/EF Door NO.:1~255; AAA=WG Reader Door NO.:1~255
B. Changing the Node ID of Reader
Programming
A. Entering and Exiting Programming Mode
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input
876112
→
Access programming mode
Add New Tags
Add by Presenting Tags (apply to Single Tag or a Batch of Tags)
[Add single tag] Add a new tag for selected user address 100:
Enter program mode
→
19 00100 00001
→ Present the tag → Successfully added tag of user 100
[Add 2 additional tags] Add new tags to the following user address 101-102:
Enter program mode
→
19 00101 00001
→
Present (User 101) card
→
Present (User 102) card
→ Successfully added tags of user 101-102
[Add 10 additional tags] Add new tags to the following user address 103-112
Enter program mode
→
19 00103 00001
→
Present (User 103) card
→
Present (User 104) card
→
Present (...) card
→
Present (User 111) card
→
Present (User 112) card
→
Successfully added tags of user 103-112
※
Important Notice:
Please remember the last user address being added to make sure the old user data is not being over written
with the new card in the future.
Delete All Tags
Input 123456 (or Master Code)
→
29 29
Delete Single Tag or a Batch of Tags (by User Address)
Input 123456 (or Master Code)
→
10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Enter program mode
→
10 00058 00058
[e.g.] Delete User Address: 00058~00063
Enter program mode
→
10 00058 00063
9
9
9
Tag Information
(125kHz)
※
For Mifare tags, the separator between Site Code & Card Code is comma "
,
".
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Delete Tags
Mode Support
User
Capacity
Access Mode
Event
Capacity
120
Holidays Duress
Time
Zone
Lift
Control
Anti-pass-
back
M4
Networking/
Stand-Alone
16,000
(0~15,999)
1.Card only
2.Card and PIN
(4-8 digit PIN Can be set)
3.Card or User address
(5-digit)
+ Individual PIN
(4-8 digit individual PIN Can be set )
32,000
V
V
unlimited
64
V
M8
1.Card only
2.Card and PIN
(4-8 digit individual PIN Can be set)
3.Card or PIN
(4-8 digit individual PIN Can be set)
C.Setting up the control mode (M4/M8)
Access programming mode
→
04 N [N=4/8]