![Southwire 23090T MaintenancePRO Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/southwire/23090t-maintenancepro/23090t-maintenancepro_operating-instructions-manual_1337720009.webp)
8
12
Span.
Operation cont.
REL/HZ Button
The RELATIVE function zeros out the reading on the display and stores it as a reference.
Subsequent readings will be displayed as the relative difference between the actual
measurement and the stored reference value. To activate, momentarily press the
REL/Hz
button. The
“REL”
indicator will appear on the LCD display along with the relative
reading. Momentarily press the
REL/HZ
button again to return to normal operation.
To select Frequency when the meter is set to AC Voltage or AC Current, press and hold
the
REL/HZ
button until the
“Hz
” indicator appears on the LCD display. To display
Duty Cycle, press and hold the REL/HZ button again until the
“%”
indicator appears
on the LCD display. While displaying % Duty Cycle, press and hold the
REL/HZ
button
to return to voltage or current readings.
MAX/MIN Button
The
MAX/MIN
function displays the highest and lowest measurements.
The readings are updated every time a higher or lower measurement is captured.
To activate, momentarily press the
MAX/MIN
button.
“MAX”
will appear on the
LCD display along with the highest reading. Momentarily press the
MAX/MIN
button to sequence the meter from MAX to MIN, from MIN to the actual reading,
and from the actual reading back to MAX.
“MIN”
will appear when the lowest
reading is displayed and
“MAX MIN”
will appear when the actual reading is
displayed. Press and hold the
MAX/MIN
button to end MAX/MIN and return to normal
operation. (MAX/MIN does not operate on Resistance, Continuity, or Capacitance)
Bluetooth
®
/Flashlight Button
Bluetooth
®
allows readings to be displayed and stored on mobile devices.
To activate Bluetooth
®
, press and hold the blue button on the side of the meter
until the symbol appears on the LCD display. Bluetooth
®
should be disabled
when not connected to a mobile device in order to conserve battery power.
To turn off Bluetooth
®
, press and hold the blue button until the symbol no
longer appears on the display.
Visit
nextgenmeters.southwire.com
for mobile app download information.
To turn the
Flashlight
on, momentarily press the
blue button
on the side of the meter.
Momentarily press the
blue button
again to turn the flashlight off.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks
by Southwire Company, LLC. is under license. Other trademarks and trade names are those of their respective owners.
Prueba de Continuidad
1. Coloque el interruptor de función rotativa a la posición .
2. Pulse el botón
MODE
hasta que el símbolo de
aparezca en la pantalla.
3. Inserte el cable de prueba negro en la toma de entrada
COM
y el cable de prueba rojo en la toma de entrada
Ω
.
4. Toque el dispositivo o cable bajo prueba con las sondas
de los cables de prueba.
5. Una señal acústica sonará si la resistencia es de
aproximadamente 50 ohmios o menos y el valor de
la resistencia se mostrará en la pantalla LCD.
500A
1000A
PEAK
MODE
REL
Hz
INRUSH
Data Logging Clamp Meter
AUTO
POWER
OFF
MAX
MIN
23090T
Non-Contact
Voltage Detector
CAT IV 600V
CAT III 1000V
Operación cont.
Nunca pruebe la continuidad en un circuito activo.
ADVERTENCIAS: