Southwire 23090T MaintenancePRO Скачать руководство пользователя страница 4

3

17

Span.

Potential danger. Indicates the user must refer to the manual for important safety information
Indicates hazardous voltages may be present

Equipment is protected by double or reinforced insulation

Indicates the terminal(s) so marked must not be connected to a circuit where the

voltage with respect to earth ground exceeds the maximum safety rating of the meter 

Indicates the terminal(s) so marked may be subjected to hazardous voltages

MAX

1000V

International Safety Symbols

Brief Description

Typical Applications

Category Rating

Single phase receptacles 

and connected loads 

Three phase circuits and 

single phase lighting 

circuits in commercial 

buildings 

- Household appliances, power tools

- Outlets more than 30ft (10m) from a CAT III source

- Outlets more than 60ft (20m) from a CAT IV source
- Equipment in fixed installations such as 3-phase 

  motors, switchgear and distribution panels 

- Lighting circuits in commercial buildings

- Feeder lines in industrial plants

- Any device or branch circuit that is close to a CAT III source

CAT II

CAT III

The measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any

accessories connected to the meter and test probes. The combination rating is the LOWEST of any individual component.

CAT IV

Connection point to

utility power and

outdoor conductors 

- Primary distribution panels

- Overhead or underground lines to detached buildings

- Incoming service entrance from utility

- Outdoor pumps

Safety Category Ratings

FCC COMPLIANCE

Users of this product are cautioned not to make modifications or changes that are not approved by

Southwire Company, LLC. Doing so may void the compliance of this product with applicable FCC requirements

and may result in the loss of the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC rules and with RSS-247 of Industry Canada. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any 

interference received, including interference that can cause undesired operation.

FCC Digital Emissions Compliance

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference 

to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged 

to try to correct the interference by one or more of the following measures:

   • Reorient or relocate the radio or television receiving antenna.
   • Increase the separation between the computer equipment and receiver.
   • Connect the equipment into an outlet on a circuit different from that to which the radio or television receiver is connected.
   • Consult the dealer or an experienced radio television technician for help.
FCC ID:2AENI-23090T

Canadian Digital Apparatus Compliance

IC:20144-23090T
CAN ICES-3 (B)/NMB-3(B)  

,ZWLJPÄJHJPVULZ

 cont.

500.00nF
5000.0nF
50.000µF
500.00µF
5.000mF

Protección de Entrada: 

600V AC rms o 600V DC

10pF
0.1nF
1nF
10nF
1µF

±(3.5% +40 dígitos)

±(5.0% +10 dígitos)

Capacitancia
(Rango Automático)

50.000Hz
500.00
5.0000kHz
50.000kHz
500.00kHz
5.0000MHz
10.000MHz

Protección de Entrada:  600V AC rms o 600V DC
Sensibilidad:  

>5V AC rms

0.001Hz
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
1kHZ

±(0.3% +2 dígitos)

Frecuencia
(Rango Automático)

Frecuencia y Ciclo de Trabajo a través de los cables de prueba cuando el medidor está ajustado a Hz%

500.00

Ω

5.0000k

Ω

50.000k

Ω

500.00k

Ω

5.0000M

Ω

50.000M

Ω

Protección de Entrada: 

600V AC rms o 600V DC

0.01

Ω

0.1

Ω

1

Ω

10

Ω

100

Ω

1k

Ω

±(1.0% +9 dígitos)

±(1.0% +5 dígitos)

±(2.0% +10 dígitos)
±(3.0% +10 dígitos)

Resistencia 

(Rango Automático)

    Función                  Rango

         

Resolución

    

Precisión ± 

(% de l dígitos)

    Función                  Rango

         

Resolución

    

Precisión ± 

(% de l dígitos)

    Función                  Rango

         

Resolución

    

Precisión ± 

(% de l dígitos)

This device complies with FCC and IC RF radiation exposure limits set forth for general population (uncontrolled exposure).

This device must not be collocated or operating in conjunction with any other antenna or transmitter.

Содержание 23090T MaintenancePRO

Страница 1: ...ls com 1 855 SW T00LS Toll Free Technical Help L nea de Ayuda T cnica Gratuita Scan for warranty information and to access our mobile site Escanea para informaci nde garant a y acceso a nuestro sitio...

Страница 2: ...este manual En Southwire estamos dedicados a proveer la mejor experiencia al cliente Al seguir unos pasos r pidos para registrar su producto usted puede recibir un servicio m s r pido ayuda m s efecti...

Страница 3: ...30 minutes 9 x 3 x 1 6 230 x 76 x 40mm 0 69lb 315g Complies with UL 61010 1 3rd edition for measurement CAT IV 600V CAT lll 1000V Pollution Degree 2 span 18 40Hz a 1kHz 20 a 80 Protecci n de Entrada 1...

Страница 4: ...sions Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pr...

Страница 5: ...1000A Ancho de banda actual AC 50 a 60 Hz Corriente AC actual se especifica desde 5 a 100 del rango 10mA 0 1A 2 5 5 d gitos Corriente AC 500 00A 1000 0A Entrada M xima 1000A AC rms o DC 1000A 10mA 0...

Страница 6: ...ater a 1 Cuando la bater a se agote el s mbolo aparecer en la pantalla LCD Reemplace la bater a inmediatamente 2 Utilice un peque o destornillador de punta plana para aflojar el tornillo 3 Retire la c...

Страница 7: ...electricidad est tica y otras fuentes de energ a el ctrica pueden activar aleatoriamente el detector Esta es una operaci n normal El detector s lo activa la luz indicadora cuando el voltaje AC est pre...

Страница 8: ...is applied the meter will display and hold the INRUSH current reading To return to normal operation momentarily press the PEAK INRUSH button 13 Prueba de Capacitancia 1 Coloque el interruptor de funci...

Страница 9: ...does not operate on Resistance Continuity or Capacitance Bluetooth Flashlight Button Bluetooth allows readings to be displayed and stored on mobile devices To activate Bluetooth press and hold the bl...

Страница 10: ...ng the MODE button In the DC mode allow time for the meter to Zero before taking a measurement If necessary press the REL Hz button to Zero out any DC offset Zeroing the meter is not necessary when me...

Страница 11: ...T IV 600V CAT III 1000V 10 Mediciones de Voltaje AC DC 1 Para las mediciones de voltaje de hasta 1000V ajuste el interruptor de funci n rotativa en la posici n V Para las mediciones de 500mV o menos a...

Страница 12: ...rruptor a la funci n deseada Para desactivar el apagado autom tico ajuste el interruptor de funci n en la posici n de apagado Mantenga pulsado el bot n MODE mientras ajusta el interruptor de funci n e...

Страница 13: ...e o voltaje Bot n MAX MIN La funci n MAX MIN muestra las medidas m s altas y m s bajas Las lecturas se actualizan cada vez que una medici n superior o inferior es capturada Para activar presione momen...

Страница 14: ...e el bot n HOLD de nuevo para volver al funcionamiento normal La luz de fondo ilumina la pantalla cuando la luz de ambiente es demasiado baja para ver las lecturas Para encender o apagar la luz de fon...

Страница 15: ...G Non Contact AC Voltage Detector 110 to 1000V AC WARNING Risk of Electrocution Before use always test the Voltage Detector on a known live circuit to verify proper operation WARNING Insulation type a...

Страница 16: ...r is securely fastened to the meter WARNING To avoid electric shock remove the test leads from the meter before removing the battery cover WARNINGS screw 5 Descripci n del Metro 2 1 3 6 10 12 15 9 4 5...

Страница 17: ...5V 50 500 1000V 1000V AC rms or 1000V DC 0 01mV 0 1mV 1mV 10mV 0 1V 1 0 8 digits 1 5 3 digits DC mV DC Voltage Autoranging Function Range Resolution Accuracy of reading digits Mantenimiento Esta Pinz...

Страница 18: ...el metro cables de pruebas y cualquier accesorio conectado al metro y cables de pruebas La combinaci n de clasificaci n es la M S BAJA de cualquier componente individual CUMPLIMIENTO CON FCC Se advier...

Страница 19: ...encia Prueba de Diodo Continuidad Capacitancia Temperatura C F 1000A AC DC 1000V AC DC 600V AC DC 600V AC DC 2 CAT III 1000V CAT IV 600V CAT II 1000V Punta Aislada Encendia Punta Aislada Retirada ADVE...

Страница 20: ...an Pg 1 start INTRO Introducci n 1 La Pinza Amperim trica 23090T MaintenancePRO 1000A TrueRMS AC DC con aplicaci n m vil MApp mide la corriente AC y DC hasta 1000A y ofrece una cali caci n de segurida...

Отзывы: