background image

10 A

16040T

MAX

MIN

MODE

11

Operation cont.

1. Set the rotary function switch to the 

   

 

          

position.

2. Press the 

MODE

 button until the “    “ symbol appears 

    on the LCD display. 
3. Insert the black test lead into the 

COM

 input jack and 

    the red test lead into the 

Ω

 input jack.

4. Touch the test lead probes to the diode under test. 
5. Forward voltage will indicate 0.4 to 

    0.7 on the LCD display. Reverse 

    voltage will indicate “OL”. Shorted 

    devices will indicate near 0 and 

    an open device will indicate “OL” 

    in both polarities.

Diode Test

 

 

Never test diodes in a live circuit.  

WARNING:   

Red               Black     Black           Red

 

Probe            Probe    Probe           Probe

 

Forward test   Reverse test  

 

 

1. Set the rotary function switch to the 

                  position. 

2. Press the 

MODE

 button until the “

Ω

” 

    symbol appears on the display. 

3. Insert the black test lead into the 

COM

 

    input jack and the red test lead into 

    the 

Ω

 input jack.

4. Touch the test lead probes to the component 

    under test. If the component is installed in a 

    circuit, it is best to disconnect one side before 

    testing to eliminate interference with other devices.

5. Read the resistance in on the LCD display.

Resistance Measurements

   Never test resistance on a live circuit  

WARNING:  

Ω

10 A

16040T

MAX

MIN

MODE

10 A

16040T

MAX

MIN

MODE

10 A

16040T

MAX

MIN

MODE

10 A

16040T

MAX

MIN

MODE

12

Operation cont.

1. Set the rotary function switch to 

    the               position    

2. Press the 

MODE

 button until 

    the “

nF

” symbol appears on 

    the display. 

3. Insert the black test lead into the 

    

COM

 input jack and the red test 

    lead into the 

Ω

 input jack.

4. Touch the test lead probes to the 

    capacitor under test. 

5. Read the capacitance value on the LCD display. 

    It may take up to a minute to get a stable reading 

    on large capacitors.

Capacitance Measurements

   Safely discharge capacitors before 

taking capacitance measurements.  

WARNING:  

1. Set the rotary function switch to 

    the 

   

 

          

position.

2. Press the

 MODE

 button until 

    the “   ” symbol appears on the 

    LCD display.
3. Insert the black test lead into the 

    

COM

 input jack and the red test 

    lead into the 

Ω

 input jack.

4. Touch the test lead probes to the 

    device or wire under test. 
5. A beeper will sound if the resistance is approximately 

    50

Ω

 or less and the resistance value will be shown 

    on the LCD display. 

Continuity

WIRE

   Never test continuity on a live circuit.

WARNING:  

10 A

16040T

MAX

MIN

MODE

10 A

16040T

MAX

MIN

MODE

Содержание 16040T

Страница 1: ...A 30119 2016 Southwire Company LLC All rights reserved Tous droits r serv s southwiretools com 1 855 SW T00LS Toll Free Technical Help Assistance technique gratuite L nea de Ayuda T cnica Gratuita Las...

Страница 2: ...as take measurements from a safe distance Visit nextgenmeters southwiretools com for mobile app download information Functions include AC DC voltage and current resistance continuity capacitance freq...

Страница 3: ...subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device...

Страница 4: ...capacitance nano 10 9 micro 10 6 milli 10 3 kilo 103 mega 106 Overload Auto Power Off Low battery Autoranging Display hold Maximum Minimum Bluetooth Technology 10A 16040T MAX MIN MODE 5 Meter Descript...

Страница 5: ...ccurs 2 Momentarily press the MAX MIN button again to view the lowest reading MIN will appear on the LCD display and the meter will display and hold the lowest reading The meter will update the readin...

Страница 6: ...AC DC set the rotary function switch to the mA position and insert the red test lead into the mA input jack 4 For current measurements up to 4000 A AC DC set the rotary function switch to the A posit...

Страница 7: ...ad the resistance in on the LCD display Resistance Measurements Never test resistance on a live circuit WARNING 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX M...

Страница 8: ...w on the fuse cover 2 Remove the fuse cover 3 Gently remove fuse and install new fuse into the holder 4 Always use a UL recognized fuse of the proper size and value 500mA 600V 5 x 20mm fast blow for t...

Страница 9: ...ange Input Protection 600V RMS or 600V DC Accuracy is given at 65 F to 83 F 18 C to 28 C less than 70 relative humidity 1mV 10mV 0 1V 1V 1 0 5 digits 1 2 5 digits AC Voltage 50 60Hz Function Range Res...

Страница 10: ...ifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly limited to Southwire s repair or replacement...

Страница 11: ...nt de l application mobile Les fonctions du multim tre incluent la mesure d intensit s et de tensions CA CC la mesure de r sistances la v rification de la continuit la mesure de capacit s la mesure de...

Страница 12: ...une installation particuli re Si cet quipement provoque effectivement des interf rences nuisibles la r ception de la radio ou de la t l vision ce qu on peut d terminer en teignant et rallumant l quipe...

Страница 13: ...i 10 3 kilo 103 mega 106 Surcharge Extinction automatique Pile faible S lection automatique de calibre Maintien de l affichage Valeur maximum minimum BluetoothMD 10A 16040T MAX MIN MODE 5 Description...

Страница 14: ...au bri vement sur le bouton MAX MIN pour afficher la valeur la plus basse L indicateur MIN s affiche alors sur l cran LCD aux c t s de la valeur la plus basse Le multim tre actualise la valeur d s qu...

Страница 15: ...connecteur d entr e mA 4 Pour mesurer des courants inf rieurs 4000 A CA CC tournez le s lecteur rotatif la position A puis branchez la sonde rouge dans le connecteur d entr e mA 5 Enfoncez le bouton M...

Страница 16: ...RTISSEMENT Ne testez jamais une diode sur un circuit sous tension AVERTISSEMENT 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE Tension directe Tension inverse Sonde rouge Sonde rouge Sonde noire Sond...

Страница 17: ...OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR FUSE COVER F10A 600V WARNING F500mA 600V Fonctionnement suite 1 Retirez la vis Phillips sur le co...

Страница 18: ...pulsion 100 s 100 ms Largeur de fr quence de 5 Hz 150 kHz Sensibilit 1 V RMS Fonction Plage R solution Pr cision de lecture nombre de chiffres Fonction Plage R solution Pr cision de lecture nombre de...

Страница 19: ...NE AUCUNE AUTRE GARANTIE TANT EXPLICITE QU IMPLICITE AUTRE QUE CELLES MENTIONN ES LA PR SENTE SOUTHWIRE NE POURRA PAS TRE TENUE RESPONSABLE D VENTUELS DOMMAGES INCIDENTS CONS CUTIFS INDIRECTS SP CIAUX...

Страница 20: ...uthwiretools com para obtener informaci n sobre descargas de aplicaciones m viles Las funciones incluyen voltaje y corriente AC DC resistencia continuidad capacidad frecuencia ciclo de trabajo y prueb...

Страница 21: ...salida si dicha funci n est disponible Cumple con las Normas de IDA DA107392 Mantenimiento Este Mult metro est dise ado para proporcionar a os de servicio confiable si se llevan a cabo las siguientes...

Страница 22: ...nterna Bluetooth 1 2 4 5 6 8 9 7 3 6 S mbolos Utilizados en la Pantalla LCD V A AC DC Hz F n m k M OL AUTO MAX MIN H Voltios Amperios Corriente alterna Corriente continua Signo de menos Hertz frecuenc...

Страница 23: ...Presione moment neamente el bot n de MAX MIN nuevamente para ver la lectura m s baja MIN aparecer en la pantalla LCD y el probador indicar y retendr la lectura m s baja El probador actualizar la lect...

Страница 24: ...l cable de prueba rojo en la toma de entrada mA 4 Para medidas de corriente hasta 4000 A AC DC ajuste el interruptor de funci n rotativa a la posici n de A e inserte el cable de prueba rojo en la toma...

Страница 25: ...en un circuito vivo ADVERTENCIA 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE SONDA SONDA SONDA SONDA Roja Negra Negra Roja Prueba de avance Prueba de retroceso 10A 16040T MAX MIN MODE 10A 16040T M...

Страница 26: ...REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OP...

Страница 27: ...5V 400Hz a 4000Hz Funci n Rango Resoluci n Precisi n de lectura d gitos 20 0 a 80 0 Protecci n de Entrada 600V RMS o 600V DC 0 1 1 2 5 d gitos Ancho de banda del del Ciclo de Trabajo 100us 100 ms Anc...

Страница 28: ...R SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE DOCUMENTO SOUTHWIRE NO SER RESPONSABLE DE DA OS INCIDENTALES CONSECUENCIALES INDI...

Отзывы: