Input Limits

Function 

                          Maximum Input

Voltage AC or DC 
Frequency, Duty Cycle
Resistance, Continuity, Diode Test, Capacitance
µA, mA Current AC or DC
10A Current AC or DC

600V AC RMS/600V DC
600 V AC RMS/600V DC
250V AC RMS/250V DC  
500mA 600V fast acting fuse
10A 600V fast acting fuse                                           

(30 seconds max. every 15 minutes)

2

General Specifications

Insulation

Class 2, Double insulation

Diode Test

Test current 0.3mA typical, open circuit voltage < 3.3V 

Continuity Test

Audible signal if the resistance is approx. 50

Ω

 or less

Low Battery Indication

Display

4000 count LCD display                                                                                                 

Over Range Indication 

“OL” is displayed

Polarity

Minus symbol “-” is displayed for negative polarity

Measurement Rate

2 readings per second, nominal

Auto Power Off

After approx. 15 minutes of inactivity

Input Impedance

10M

Ω

 (VDC & VAC)

AC Response

True RMS

AC Bandwidth

50/60Hz

Batteries

Two “AAA” 1.5V batteries

Fuses

µA. mA ranges: 500mA/600V (5 x 20mm) fast blow fuse

10A range: 10A/600V (5 x 20mm) fast blow

Operating Temperature

41°F to 104°F (5°C to 40°C) 

Operating Humidity

Max 80% up to 87°F (31°C) decreasing linearly to 50% 

at 104°F(40°C)

Storage Temperature

-4°F to 140°F (-20°C to 60°C)

Storage Humidity

<80%)

Operating Altitude

Dimensions/ Weight

4.8” x 2.6” x 1.4”/0.32lb (121 x 67 x 35mm/140g)
Complies with UL 61010-1 v.3 for measurement 

Category lll 600V, Polution Degree 2

Safety

2000 meters

“      ” is displayed

Introduction

1

The Southwire 16040T True RMS Multimeter wirelessly transmits data to 

the MApp™ mobile app via Bluetooth

®

 technology allowing you to view, 

save, organize and share datalogs as well as take measurements from a 

safe distance. Visit nextgenmeters.southwiretools.com for mobile app 

download information. Functions include AC/DC voltage and current, 

resistance, continuity, capacitance, frequency, duty cycle, diode test. The 

16040T also offers the added convenience of a built-in flashlight. This meter 

is fully tested and calibrated and, with proper use, will provide many years 

of reliable service.  

WARNINGS

• Read, understand and follow Safety Rules and Operating Instructions in    

   this manual before using this meter.

• The meter’s safety features may not protect the user if not used in     

   accordance with the manufacturer’s instructions.

• Ensure that the test leads are fully seated in the input jacks and keep  

   fingers away from the metal probe tips when taking measurements.

• Before changing functions using the selector switch, always disconnect  

   the test leads from the circuit under test.

• Use only UL listed test leads with the proper safety category rating.  

• Comply with all applicable safety codes. Use approved personal  

   protective equipment when working near live electrical circuits -     

   particularly with regard to arc-flash potential.

• Use caution on live circuits. Voltages above 30 V AC rms, 42 V ac peak,  

   or 60 V dc pose a shock hazard.

• Do not use if the meter or test leads appear damaged.

• Verify operation before using meter by measuring a known live voltage. 

• Do not use the meter in wet or damp environments or during electrical  

   storms.

• Do not use the meter near explosive vapors, dust or gasses.

• Do not use the meter if it operates incorrectly. Protection may be  

   compromised.

• Do not operate meter while Low Battery warning is on. Replace  

   batteries immediately. 

• Do not apply voltage or current that exceeds the meter’s maximum  

   rated input limits.

Содержание 16040T

Страница 1: ...A 30119 2016 Southwire Company LLC All rights reserved Tous droits r serv s southwiretools com 1 855 SW T00LS Toll Free Technical Help Assistance technique gratuite L nea de Ayuda T cnica Gratuita Las...

Страница 2: ...as take measurements from a safe distance Visit nextgenmeters southwiretools com for mobile app download information Functions include AC DC voltage and current resistance continuity capacitance freq...

Страница 3: ...subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device...

Страница 4: ...capacitance nano 10 9 micro 10 6 milli 10 3 kilo 103 mega 106 Overload Auto Power Off Low battery Autoranging Display hold Maximum Minimum Bluetooth Technology 10A 16040T MAX MIN MODE 5 Meter Descript...

Страница 5: ...ccurs 2 Momentarily press the MAX MIN button again to view the lowest reading MIN will appear on the LCD display and the meter will display and hold the lowest reading The meter will update the readin...

Страница 6: ...AC DC set the rotary function switch to the mA position and insert the red test lead into the mA input jack 4 For current measurements up to 4000 A AC DC set the rotary function switch to the A posit...

Страница 7: ...ad the resistance in on the LCD display Resistance Measurements Never test resistance on a live circuit WARNING 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX M...

Страница 8: ...w on the fuse cover 2 Remove the fuse cover 3 Gently remove fuse and install new fuse into the holder 4 Always use a UL recognized fuse of the proper size and value 500mA 600V 5 x 20mm fast blow for t...

Страница 9: ...ange Input Protection 600V RMS or 600V DC Accuracy is given at 65 F to 83 F 18 C to 28 C less than 70 relative humidity 1mV 10mV 0 1V 1V 1 0 5 digits 1 2 5 digits AC Voltage 50 60Hz Function Range Res...

Страница 10: ...ifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly limited to Southwire s repair or replacement...

Страница 11: ...nt de l application mobile Les fonctions du multim tre incluent la mesure d intensit s et de tensions CA CC la mesure de r sistances la v rification de la continuit la mesure de capacit s la mesure de...

Страница 12: ...une installation particuli re Si cet quipement provoque effectivement des interf rences nuisibles la r ception de la radio ou de la t l vision ce qu on peut d terminer en teignant et rallumant l quipe...

Страница 13: ...i 10 3 kilo 103 mega 106 Surcharge Extinction automatique Pile faible S lection automatique de calibre Maintien de l affichage Valeur maximum minimum BluetoothMD 10A 16040T MAX MIN MODE 5 Description...

Страница 14: ...au bri vement sur le bouton MAX MIN pour afficher la valeur la plus basse L indicateur MIN s affiche alors sur l cran LCD aux c t s de la valeur la plus basse Le multim tre actualise la valeur d s qu...

Страница 15: ...connecteur d entr e mA 4 Pour mesurer des courants inf rieurs 4000 A CA CC tournez le s lecteur rotatif la position A puis branchez la sonde rouge dans le connecteur d entr e mA 5 Enfoncez le bouton M...

Страница 16: ...RTISSEMENT Ne testez jamais une diode sur un circuit sous tension AVERTISSEMENT 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE Tension directe Tension inverse Sonde rouge Sonde rouge Sonde noire Sond...

Страница 17: ...OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR FUSE COVER F10A 600V WARNING F500mA 600V Fonctionnement suite 1 Retirez la vis Phillips sur le co...

Страница 18: ...pulsion 100 s 100 ms Largeur de fr quence de 5 Hz 150 kHz Sensibilit 1 V RMS Fonction Plage R solution Pr cision de lecture nombre de chiffres Fonction Plage R solution Pr cision de lecture nombre de...

Страница 19: ...NE AUCUNE AUTRE GARANTIE TANT EXPLICITE QU IMPLICITE AUTRE QUE CELLES MENTIONN ES LA PR SENTE SOUTHWIRE NE POURRA PAS TRE TENUE RESPONSABLE D VENTUELS DOMMAGES INCIDENTS CONS CUTIFS INDIRECTS SP CIAUX...

Страница 20: ...uthwiretools com para obtener informaci n sobre descargas de aplicaciones m viles Las funciones incluyen voltaje y corriente AC DC resistencia continuidad capacidad frecuencia ciclo de trabajo y prueb...

Страница 21: ...salida si dicha funci n est disponible Cumple con las Normas de IDA DA107392 Mantenimiento Este Mult metro est dise ado para proporcionar a os de servicio confiable si se llevan a cabo las siguientes...

Страница 22: ...nterna Bluetooth 1 2 4 5 6 8 9 7 3 6 S mbolos Utilizados en la Pantalla LCD V A AC DC Hz F n m k M OL AUTO MAX MIN H Voltios Amperios Corriente alterna Corriente continua Signo de menos Hertz frecuenc...

Страница 23: ...Presione moment neamente el bot n de MAX MIN nuevamente para ver la lectura m s baja MIN aparecer en la pantalla LCD y el probador indicar y retendr la lectura m s baja El probador actualizar la lect...

Страница 24: ...l cable de prueba rojo en la toma de entrada mA 4 Para medidas de corriente hasta 4000 A AC DC ajuste el interruptor de funci n rotativa a la posici n de A e inserte el cable de prueba rojo en la toma...

Страница 25: ...en un circuito vivo ADVERTENCIA 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE SONDA SONDA SONDA SONDA Roja Negra Negra Roja Prueba de avance Prueba de retroceso 10A 16040T MAX MIN MODE 10A 16040T M...

Страница 26: ...REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OP...

Страница 27: ...5V 400Hz a 4000Hz Funci n Rango Resoluci n Precisi n de lectura d gitos 20 0 a 80 0 Protecci n de Entrada 600V RMS o 600V DC 0 1 1 2 5 d gitos Ancho de banda del del Ciclo de Trabajo 100us 100 ms Anc...

Страница 28: ...R SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE DOCUMENTO SOUTHWIRE NO SER RESPONSABLE DE DA OS INCIDENTALES CONSECUENCIALES INDI...

Отзывы: