FCC Statement

Warning:

 Changes or modifications to this unit not expressly approved by the Southwire Company, LLC. could void the user’s 

authority to operate the equipment

.

NOTE:

 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 • 

Reorient or relocate the receiving antenna.

 • 

Increase the separation between the equipment and receiver.

 • 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 • 

Consult the dealer or an experienced radio/TV technician for help.

The device must not be co-located or operating in conjunction with any other antenna or transmitter.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  

(1) this device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may cause undesired operation.

Complies with

IDA Standards

DA107392

FCC ID:  2AENI-16040T /  IC:  20144-16040T

Maintenance

This Multimeter is designed to provide years of dependable service, if the following care 

instructions are performed:

1. KEEP THE METER DRY. If it gets wet, wipe it off.

2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can 

    shorten the life of the electronic parts and distort or melt plastic parts.

3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic 

    parts or the case.

4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use 

    chemicals, cleaning solvents, or detergents.

5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or 

    weak batteries so they do not leak and damage the unit.

6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should 

    be removed to prevent damage to the unit.

IC Statement

This device complies with RSS247 of Industry Canada. This device complies with Industry Canada license-exempt RSS standard(s). 

Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any 

interference, including interference that may cause undesired operation of the device.

Radiation Exposure Statement: This product complies with the Canadian portable RF exposure limit set 

forth for an uncontrolled environment and is safe for its intended operation as described in this manual.  

Further RF exposure reduction can be achieved if the product is kept as far as possible from the user’s body.

Déclaration de conformité d’Industrie Canada

Leprésent appareil est conforme aux CNR d'Industrie Canada applicable aux appareils radio Exempts de licence. L'exploitation est 

autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter 

tout brouillage radioélectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement."

Déclaration d’exposition aux radiations : Ce produit est conforme aux limites d’exposition pour les appareils portables RF pour le 

Canada établies pour un environnement non contrôlé. Le produit est sûr pour un fonctionnement comme décrit dans ce manuel. La 

réduction aux expositions RF peut être augmentée si l’appareil peut être conservé aussi loin que possible du corps de l’utilisateur.

Insulated Tip On

Insulated Tip Removed

3

Potential danger. Indicates the user must refer to the manual for important safety information

Indicates hazardous voltages may be present

Equipment is protected by double or reinforced insulation

Indicates the terminal(s) so marked must not be connected to a circuit where the

voltage with respect to earth ground exceeds the maximum safety rating of the meter 

MAX

600V

International Safety Symbols

Brief Description

Typical Applications

Category Rating

Single phase receptacles 

and connected loads 

Three phase circuits and 

single phase lighting 

circuits in commercial 

buildings 

- Household appliances, power tools

- Outlets more than 30ft (10m) from a CAT III source

- Outlets more than 60ft (20m) from a CAT IV source
- Equipment in fixed installations such as 3-phase 

  motors, switchgear and distribution panels 

- Lighting circuits in commercial buildings

- Feeder lines in industrial plants

- Any device or branch circuit that is close to a CAT III source

CAT II

CAT III

The measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any accessories connected to 

the meter and test probes. The combination rating is the LOWEST of any individual component.

Safety Category Ratings

WARNING: 

                            Operation is limited to CAT II applications when the insulated tips are 

removed from one or both test probes. Refer to Input Limits section in this manual for maximum 

voltage ratings. 

Test Leads

CAT IV  600V

CAT III 1000V  

CAT II

1000V

Содержание 16040T

Страница 1: ...A 30119 2016 Southwire Company LLC All rights reserved Tous droits r serv s southwiretools com 1 855 SW T00LS Toll Free Technical Help Assistance technique gratuite L nea de Ayuda T cnica Gratuita Las...

Страница 2: ...as take measurements from a safe distance Visit nextgenmeters southwiretools com for mobile app download information Functions include AC DC voltage and current resistance continuity capacitance freq...

Страница 3: ...subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device...

Страница 4: ...capacitance nano 10 9 micro 10 6 milli 10 3 kilo 103 mega 106 Overload Auto Power Off Low battery Autoranging Display hold Maximum Minimum Bluetooth Technology 10A 16040T MAX MIN MODE 5 Meter Descript...

Страница 5: ...ccurs 2 Momentarily press the MAX MIN button again to view the lowest reading MIN will appear on the LCD display and the meter will display and hold the lowest reading The meter will update the readin...

Страница 6: ...AC DC set the rotary function switch to the mA position and insert the red test lead into the mA input jack 4 For current measurements up to 4000 A AC DC set the rotary function switch to the A posit...

Страница 7: ...ad the resistance in on the LCD display Resistance Measurements Never test resistance on a live circuit WARNING 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE 10A 16040T MAX M...

Страница 8: ...w on the fuse cover 2 Remove the fuse cover 3 Gently remove fuse and install new fuse into the holder 4 Always use a UL recognized fuse of the proper size and value 500mA 600V 5 x 20mm fast blow for t...

Страница 9: ...ange Input Protection 600V RMS or 600V DC Accuracy is given at 65 F to 83 F 18 C to 28 C less than 70 relative humidity 1mV 10mV 0 1V 1V 1 0 5 digits 1 2 5 digits AC Voltage 50 60Hz Function Range Res...

Страница 10: ...ifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly limited to Southwire s repair or replacement...

Страница 11: ...nt de l application mobile Les fonctions du multim tre incluent la mesure d intensit s et de tensions CA CC la mesure de r sistances la v rification de la continuit la mesure de capacit s la mesure de...

Страница 12: ...une installation particuli re Si cet quipement provoque effectivement des interf rences nuisibles la r ception de la radio ou de la t l vision ce qu on peut d terminer en teignant et rallumant l quipe...

Страница 13: ...i 10 3 kilo 103 mega 106 Surcharge Extinction automatique Pile faible S lection automatique de calibre Maintien de l affichage Valeur maximum minimum BluetoothMD 10A 16040T MAX MIN MODE 5 Description...

Страница 14: ...au bri vement sur le bouton MAX MIN pour afficher la valeur la plus basse L indicateur MIN s affiche alors sur l cran LCD aux c t s de la valeur la plus basse Le multim tre actualise la valeur d s qu...

Страница 15: ...connecteur d entr e mA 4 Pour mesurer des courants inf rieurs 4000 A CA CC tournez le s lecteur rotatif la position A puis branchez la sonde rouge dans le connecteur d entr e mA 5 Enfoncez le bouton M...

Страница 16: ...RTISSEMENT Ne testez jamais une diode sur un circuit sous tension AVERTISSEMENT 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE Tension directe Tension inverse Sonde rouge Sonde rouge Sonde noire Sond...

Страница 17: ...OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR FUSE COVER F10A 600V WARNING F500mA 600V Fonctionnement suite 1 Retirez la vis Phillips sur le co...

Страница 18: ...pulsion 100 s 100 ms Largeur de fr quence de 5 Hz 150 kHz Sensibilit 1 V RMS Fonction Plage R solution Pr cision de lecture nombre de chiffres Fonction Plage R solution Pr cision de lecture nombre de...

Страница 19: ...NE AUCUNE AUTRE GARANTIE TANT EXPLICITE QU IMPLICITE AUTRE QUE CELLES MENTIONN ES LA PR SENTE SOUTHWIRE NE POURRA PAS TRE TENUE RESPONSABLE D VENTUELS DOMMAGES INCIDENTS CONS CUTIFS INDIRECTS SP CIAUX...

Страница 20: ...uthwiretools com para obtener informaci n sobre descargas de aplicaciones m viles Las funciones incluyen voltaje y corriente AC DC resistencia continuidad capacidad frecuencia ciclo de trabajo y prueb...

Страница 21: ...salida si dicha funci n est disponible Cumple con las Normas de IDA DA107392 Mantenimiento Este Mult metro est dise ado para proporcionar a os de servicio confiable si se llevan a cabo las siguientes...

Страница 22: ...nterna Bluetooth 1 2 4 5 6 8 9 7 3 6 S mbolos Utilizados en la Pantalla LCD V A AC DC Hz F n m k M OL AUTO MAX MIN H Voltios Amperios Corriente alterna Corriente continua Signo de menos Hertz frecuenc...

Страница 23: ...Presione moment neamente el bot n de MAX MIN nuevamente para ver la lectura m s baja MIN aparecer en la pantalla LCD y el probador indicar y retendr la lectura m s baja El probador actualizar la lect...

Страница 24: ...l cable de prueba rojo en la toma de entrada mA 4 Para medidas de corriente hasta 4000 A AC DC ajuste el interruptor de funci n rotativa a la posici n de A e inserte el cable de prueba rojo en la toma...

Страница 25: ...en un circuito vivo ADVERTENCIA 10A 16040T MAX MIN MODE 10A 16040T MAX MIN MODE SONDA SONDA SONDA SONDA Roja Negra Negra Roja Prueba de avance Prueba de retroceso 10A 16040T MAX MIN MODE 10A 16040T M...

Страница 26: ...REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OPENING CASE OR BATTERY DOOR WARNING TO AVOID ELECTRIC SHOCK REMOVE TEST LEADS BEFORE OP...

Страница 27: ...5V 400Hz a 4000Hz Funci n Rango Resoluci n Precisi n de lectura d gitos 20 0 a 80 0 Protecci n de Entrada 600V RMS o 600V DC 0 1 1 2 5 d gitos Ancho de banda del del Ciclo de Trabajo 100us 100 ms Anc...

Страница 28: ...R SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE DOCUMENTO SOUTHWIRE NO SER RESPONSABLE DE DA OS INCIDENTALES CONSECUENCIALES INDI...

Отзывы: