Introduction

WARNINGS

1

The Southwire 10040N multimeter measures AC and DC voltage and 

current, resistance, capacitance, frequency, duty cycle and tempera-

ture. It also tests continuity, diodes, and has a built-in non-contact 

AC voltage detector. Readings are displayed on a large backlit LCD. 

This meter is fully tested and calibrated and, with proper use, will 

provide many years of reliable service.

  

• Read, understand and follow the Safety Rules and Operating    

   Instructions in this manual before using this meter.

• The meter’s safety features may not protect the user if not  

   used in accordance to the manufacturer’s instructions. 

• Ensure that the test leads are fully seated in the input jacks and       

   keep fingers away from the metal probe tips when taking          

   measurements.

• Before changing functions using the rotary function switch,

   always disconnect the test leads from the circuit under test. 

• Use only UL listed test leads with the proper safety category rating. 

• Comply with all safety codes. Use approved personal protective  

  equipment when working near live electrical circuits - particularly  

   with regard to arc-flash potential.

• Use caution on live circuits. Voltages above 30 V AC RMS, 42 V    

   AC peak, or 60 V DC pose a shock hazard.

• Do not use meter or test leads if they appear damaged.

• Do not use the meter if it operates incorrectly. Protection may    

   be compromised. 

• Verify meter’s operation by measuring a known voltage. 

• Do not use the meter in wet or damp environments or during    

   electrical storms.

• Do not use the meter near explosive vapors, dust or gasses.

• Do not use the meter if it operates incorrectly. Protection may 

   be compromised.

• Replace the battery as soon as the low battery warning appears.  

2

Input Limits

Function 

 Maximum Input

Voltage  AC or DC 

µA/mA AC or DC

10A AC or DC

Resistance, Continuity, Diode 

Test, Frequency, Duty Cycle
Temperature

600V

400mA, 250V

10A AC or DC (30 seconds max every 

15 minutes), 250V

250V

250V 

General Specifications

Insulation      
Overvoltage Category 
Display 
Polarity 
Continuity
Overrange
Low Battery Indication  

Measurement Rate 

 

Auto Power Off 
Operating Environment 
Storage Temperature 
Operating Altitude 
Pollution Degree 
Battery
Dimensions:  
Weight
Safety 

Class2, Double insulation
CAT III 600V

4000 counts LCD display with function indication
Automatic, (-) negative polarity indication.
Audible indication if the resistance is approximately 30

Ω

 or less

“OL” mark indication.
The “     ”  symbol  is displayed when the battery voltage 
drops below the operating  level.
2 times per second, nominal.

Meter automatically shuts down after approx. 15 minutes of inactivity.
32° to 104°F (0°C to 40°C) at < 80 % relative humidity.
14° to 140°F (-10° to 60°C) at < 80 % relative humidity.
7000ft (2000m)
2
One 9V battery, NEDA 1604, IEC 6F22
5.4” x 2.7” x 1.5” (138 x 68 x 37mm)
0.46lb (210g)

For indoor use and in accordance with Overvoltage Category III,

Pollution Degree 2.  Conforms to UL 61010-1 v.2

• Do not apply voltage or current that exceeds the meter’s    

   

   maximum rated input limit.